Reference record for OID 0.0.17.835.0.3.9


parent
0.0.17.835.0.3 (managedObjectClass)
node code
9
node name
metallicTestAccess
dot oid
0.0.17.835.0.3.9
asn1 oid
  • {itu-t(0) recommendation(0) q(17) q835(835) informationModel(0) managedObjectClass(3) metallicTestAccess(9)}
  • {itu-t(0) null(0) q(17) q835(835) informationModel(0) managedObjectClass(3) metallicTestAccess(9)}
  • {ccitt(0) recommendation(0) q(17) q835(835) informationModel(0) managedObjectClass(3) metallicTestAccess(9)}
  • {ccitt(0) null(0) q(17) q835(835) informationModel(0) managedObjectClass(3) metallicTestAccess(9)}
  • iri oid
  • /itu-t/recommendation/q/q835/informationModel/managedObjectClass/metallicTestAccess
  • /itu-t/null/q/q835/informationModel/managedObjectClass/metallicTestAccess
  • /ccitt/recommendation/q/q835/informationModel/managedObjectClass/metallicTestAccess
  • /ccitt/null/q/q835/informationModel/managedObjectClass/metallicTestAccess
  • iri by oid_info
    /ITU-T/Recommendation/Q/835/0/3/9

    Description by oid_info

    metallicTestAccess MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    "Recommendation ITU-T X.745":mORTsPackage,
    metallicTestAccessPkg PACKAGE
    BEHAVIOUR
    metallicTestAccessPkgBehaviour BEHAVIOUR
    DEFINED AS "The test establishes a physical connection between an instance of MORT and a measurement interface of an external test system.
    The OS identifies the measurement interface in parameter numberOfMTA, which is included in the information syntax of testRequestControlledAction.
    In case the measurement interface is not available for any reason, the NE automatically tries to connect the MORT to an alternative measurement interface. In both cases, the attribute proposedMTA indicates the measurement interface where the MORT is physically connected to.
    The attribute mtaMsg contains the return value of a successful connection.
    The connection will be released after the time defined by attribute mtaTimeoutPeriod. In this case, all test-related resources are released, the instance of metallicTestAccess is implicitly deleted, and an objectDeletionNotification is generated. Setting the attribute mtaTimeoutPeriod extends the connection time by the indicated value.";;
    ATTRIBUTES
    mtaTimeoutPeriod DEFAULT VALUE
    ASN1LLCTTypeModule.defaultMtaTimeoutPeriod GET-REPLACE,
    mtaMsg GET,
    proposedMTA GET;
    NOTIFICATIONS
    "Recommendation ITU-T X.721":objectDeletion;;;
    CONDITIONAL PACKAGES
    testEnvironmentConditionsPackage PRESENT IF "an instance supports it",
    mtaLinePackage PRESENT IF "the metallic test access is a two-wire interface.";

    View at oid-info.com

    Information by oid_info

    Automatically extracted from Rec. ITU-T Q.835

    First Registration Authority (recovered by parent 0.0.17)

    ITU-T

    Current Registration Authority (recovered by parent 0)

    ITU-T Study Group 17

    Brothers (15)

    OIDNameSub childrenSub Nodes TotalDescription
    0.0.17.835.0.3.1 accessTest 0 0 accessTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    testEnvironmentConditio…
    0.0.17.835.0.3.2 cablePairIdTone 0 0 cablePairIdTone MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    cablePairIdTonePkg…
    0.0.17.835.0.3.3 dialledDigitTest 0 0 dialledDigitTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    dialledDigitTestP…
    0.0.17.835.0.3.4 dialToneTest 0 0 dialToneTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    dialToneTestPkg PACKA…
    0.0.17.835.0.3.5 dryLoop 0 0 dryLoop MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    dryLoopPkg PACKAGE
    BEHAVIO…
    0.0.17.835.0.3.6 electricalMeasurementTest 0 0 electricalMeasurementTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    electric…
    0.0.17.835.0.3.7 isdnQuickTest 0 0 isdnQuickTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    "Recommendation ITU-…
    0.0.17.835.0.3.8 loopTest 0 0 loopTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    testEnvironmentConditions…
    0.0.17.835.0.3.10 patternTest 0 0 patternTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    patternTestPkg PACKAGE…
    0.0.17.835.0.3.11 ringing 0 0 ringing MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    ringingPkg PACKAGE
    BEHAVIO…
    0.0.17.835.0.3.12 spmPulses 0 0 spmPulses MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    spmPulsesPkg PACKAGE
    BEH…
    0.0.17.835.0.3.13 testToLineCircuit 0 0 testToLineCircuit MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    testToLineCircui…
    0.0.17.835.0.3.14 testThresholdClass 0 0 testThresholdClass MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.721":top;
    CHARACTERIZED BY
    testThresholdClassPkg P…
    0.0.17.835.0.3.15 voiceAccessTest 0 0 voiceAccessTest MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.745": testObject;
    CHARACTERIZED BY
    voiceAccessPackage…
    0.0.17.835.0.3.16 anRbsTreatment 0 0 anRbsTreatment MANAGED OBJECT CLASS
    DERIVED FROM "Recommendation ITU-T X.721": top;
    CHARACTERIZED BY
    anRbsTreatmentPackage PACK…