Reference record for OID 1.3.111.2.802.1.1.18.1.2.1.1
- parent
- 1.3.111.2.802.1.1.18.1.2.1 (ieee8021CnErroredPortEntry)
- node code
- 1
- node name
- ieee8021CnEpComponentId
- dot oid
- 1.3.111.2.802.1.1.18.1.2.1.1
- type
- OBJECT-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnErroredPortTable(2) ieee8021CnErroredPortEntry(1) ieee8021CnEpComponentId(1)}
- {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnErroredPortTable(2) ieee8021CnErroredPortEntry(1) ieee8021CnEpComponentId(1)}
- {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnErroredPortTable(2) ieee8021CnErroredPortEntry(1) ieee8021CnEpComponentId(1)}
- {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnErroredPortTable(2) ieee8021CnErroredPortEntry(1) ieee8021CnEpComponentId(1)}
- {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnErroredPortTable(2) ieee8021CnErroredPortEntry(1) ieee8021CnEpComponentId(1)}
- {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnErroredPortTable(2) ieee8021CnErroredPortEntry(1) ieee8021CnEpComponentId(1)}
- iri oid
-
- /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnErroredPortTable/ieee8021CnErroredPortEntry/ieee8021CnEpComponentId
- /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnErroredPortTable/ieee8021CnErroredPortEntry/ieee8021CnEpComponentId
- /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnErroredPortTable/ieee8021CnErroredPortEntry/ieee8021CnEpComponentId
- /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnErroredPortTable/ieee8021CnErroredPortEntry/ieee8021CnEpComponentId
- /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnErroredPortTable/ieee8021CnErroredPortEntry/ieee8021CnEpComponentId
- /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnErroredPortTable/ieee8021CnErroredPortEntry/ieee8021CnEpComponentId
- iri by oid_info
- /ISO/Identified-Organization/111/2/802/1/1/18/1/2/1/1
Description by oid_info
ieee8021CnEpComponentId OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge component within the system to which the information
in this ieee8021CnErroredPortEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"802.1Qau clause 32.2.4"
View at oid-info.com
Description by ieee802
The bridge component within the system to which the information
in this ieee8021CnErroredPortEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
Information by oid_info
Automatically extracted from IEEE Management Information Bases (MIBs)
Information by ieee802
ieee8021CnEpComponentId OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge component within the system to which the information
in this ieee8021CnErroredPortEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"802.1Qau clause 32.2.4"
::= { ieee8021CnErroredPortEntry 1 }
Current Registration Authority (recovered by parent 1.3)
Frank Farance
Brothers (2)
OID | Name | Sub children | Sub Nodes Total | Description |
1.3.111.2.802.1.1.18.1.2.1.2 |
ieee8021CnEpPriority |
0 |
0 |
The priority value whose alternate priority is misconfigured. |
1.3.111.2.802.1.1.18.1.2.1.3 |
ieee8021CnEpIfIndex |
0 |
0 |
This object represents the Bridge Port or aggregated port on which the congestion notification alternate priority is misconfigureā¦ |