ieee8021AsDefaultDSOffsetScaledLogVariance OBJECT-TYPE
SYNTAX Integer32(-32768..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The offsetScaledLogVariance is scaled, offset
representation of an estimate of the PTP variance. The
PTP variance characterizes the precision and frequency
stability of the ClockMaster. The PTP variance is the
square of PTPDEV (see B.1.3.2). The value shall be
selected as follows:
a) offsetScaledLogVariance is set to the value that
reflects the combination of the LocalClock and
ClockSource entities; else
b) if the value that reflects these entities is not
specified or not known, offsetScaledLogVariance is
set to 16640 (410016). This value corresponds to the
value of PTPDEV for observation interval equal to the
default Sync message transmission interval (i.e.,
observation interval of 0.125 s, see 11.5.2.3 and
B.1.3.2).
A value of -37268 indicates value is too large to be
represented or has not been computed.
"
REFERENCE "14.2.5"
View at oid-info.com
The offsetScaledLogVariance is scaled, offset
representation of an estimate of the PTP variance. The
PTP variance characterizes the precision and frequency
stability of the ClockMaster. The PTP variance is the
square of PTPDEV (see B.1.3.2). The value shall be
selected as follows:
a) offsetScaledLogVariance is set to the value that
reflects the combination of the LocalClock and
ClockSource entities; else
b) if the value that reflects these entities is not
specified or not known, offsetScaledLogVariance is
set to 16640 (0x4100). This value corresponds to the
value of PTPDEV for observation interval equal to the
default Sync message transmission interval (i.e.,
observation interval of 0.125 s, see 11.5.2.3 and
B.1.3.2).
A value of 65535 (0xFFFF) indicates value is too
large to be represented or has not been computed.
Automatically extracted from IEEE Management Information Bases (MIBs)
ieee8021AsDefaultDSOffsetScaledLogVariance OBJECT-TYPE SYNTAX Unsigned32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The offsetScaledLogVariance is scaled, offset representation of an estimate of the PTP variance. The PTP variance characterizes the precision and frequency stability of the ClockMaster. The PTP variance is the square of PTPDEV (see B.1.3.2). The value shall be selected as follows: a) offsetScaledLogVariance is set to the value that reflects the combination of the LocalClock and ClockSource entities; else b) if the value that reflects these entities is not specified or not known, offsetScaledLogVariance is set to 16640 (0x4100). This value corresponds to the value of PTPDEV for observation interval equal to the default Sync message transmission interval (i.e., observation interval of 0.125 s, see 11.5.2.3 and B.1.3.2). A value of 65535 (0xFFFF) indicates value is too large to be represented or has not been computed. " REFERENCE "14.2.5" ::= { ieee8021AsDefaultDS 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.111.2.802.1.1.20.1.1.1 | ieee8021AsDefaultDSClockIdentity | 0 | 0 | Globally unique manufacturer-assigned clock identifier for the local clock. The identifier is based on an EUI-64. |
1.3.111.2.802.1.1.20.1.1.2 | ieee8021AsDefaultDSNumberPorts | 0 | 0 | The number of PTP ports on the device. For an end station the value is 1. |
1.3.111.2.802.1.1.20.1.1.3 | ieee8021AsDefaultDSClockClass | 0 | 0 | Denotes the traceability of the time or frequency of the local clock. The value shall be selected as follows: a) If the Default … |
1.3.111.2.802.1.1.20.1.1.4 | ieee8021AsDefaultDSClockAccuracy | 0 | 0 | Characterizes local clock for the purpose of the best master clock algorithm. The value shall be selected as follows: a) clockAcc… |
1.3.111.2.802.1.1.20.1.1.6 | ieee8021AsDefaultDSPriority1 | 0 | 0 | Most-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The valu… |
1.3.111.2.802.1.1.20.1.1.7 | ieee8021AsDefaultDSPriority2 | 0 | 0 | Least-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The de… |
1.3.111.2.802.1.1.20.1.1.8 | ieee8021AsDefaultDSGmCapable | 0 | 0 | True (1) if master clock capable; false (2) otherwise. |
1.3.111.2.802.1.1.20.1.1.9 | ieee8021AsDefaultDSCurrentUTCOffset | 0 | 0 | The value is the offset between TAI and UTC, relative to the ClockMaster entity of this time-aware system. It is equal to the glo… |
1.3.111.2.802.1.1.20.1.1.10 | ieee8021AsDefaultDSCurrentUTCOffsetValid | 0 | 0 | True (1) if ieee8021AsDefaultDSCurrentUTCOffset is known to be correct; false (2) otherwise. |
1.3.111.2.802.1.1.20.1.1.11 | ieee8021AsDefaultDSLeap59 | 0 | 0 | A true (1) value indicates that the last minute of the current UTC day, relative to the ClockMaster entity of this time-aware sys… |
1.3.111.2.802.1.1.20.1.1.12 | ieee8021AsDefaultDSLeap61 | 0 | 0 | A true (1) value indicates that the last minute of the current UTC day, relative to the ClockMaster entity of this time-aware sys… |
1.3.111.2.802.1.1.20.1.1.13 | ieee8021AsDefaultDSTimeTraceable | 0 | 0 | The value is set to true (1) if the timescale and the value of Ieee8021AsCurrentUtcOffset, relative to the ClockMaster entity of … |
1.3.111.2.802.1.1.20.1.1.14 | ieee8021AsDefaultDSFrequencyTraceable | 0 | 0 | The value is set to true (1) if the frequency determining the timescale of the ClockMaster Entity of this time- aware system is t… |
1.3.111.2.802.1.1.20.1.1.15 | ieee8021AsDefaultDSTimeSource | 0 | 0 | The timeSource is an information-only attribute indicating the type of source of time used by a ClockMaster. The value is not use… |