ieee8021AsParentDSParentPortNumber OBJECT-TYPE
SYNTAX Unsigned32(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number (portNumber) of the local clock\s parent gPTP
port number.
If this time-aware system is the grandmaster, the value
is the gPTP portNumber of this time-aware system.
If this time-aware system is not the grandmaster, the
value is the portNumber of the MasterPort (see
Table 10-1) of the gPTP communication path attached to
the single gPTP slave port of this time-aware system.
"
REFERENCE "14.4.1"
DEFVAL { 0 }
View at oid-info.com
Port number (portNumber) of the local clock's parent gPTP
port number.
If this time-aware system is the grandmaster, the value
is the gPTP portNumber of this time-aware system.
If this time-aware system is not the grandmaster, the
value is the portNumber of the MasterPort (see
Table 10-1) of the gPTP communication path attached to
the single gPTP slave port of this time-aware system.
Automatically extracted from IEEE Management Information Bases (MIBs)
ieee8021AsParentDSParentPortNumber OBJECT-TYPE SYNTAX Unsigned32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Port number (portNumber) of the local clock's parent gPTP port number. If this time-aware system is the grandmaster, the value is the gPTP portNumber of this time-aware system. If this time-aware system is not the grandmaster, the value is the portNumber of the MasterPort (see Table 10-1) of the gPTP communication path attached to the single gPTP slave port of this time-aware system. " REFERENCE "14.4.1" DEFVAL { 0 } ::= { ieee8021AsParentDS 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.111.2.802.1.1.20.1.3.1 | ieee8021AsParentDSParentClockIdentity | 0 | 0 | Clock identifier (clockIdentity) of the local clock's parent clock. The default value is set to ieee8021AsDefaultDSClockIdentity… |
1.3.111.2.802.1.1.20.1.3.3 | ieee8021AsParentDSCumlativeRateRatio | 0 | 0 | The value is an estimate of the ratio of the frequency of the grandmaster to the frequency of the LocalClock entity of this time-… |
1.3.111.2.802.1.1.20.1.3.4 | ieee8021AsParentDSGrandmasterIdentity | 0 | 0 | Clock identifier (clockIdentity) of the grandmaster. The default value is set to ieee8021AsDefaultDSClockIdentity. |
1.3.111.2.802.1.1.20.1.3.5 | ieee8021AsParentDSGrandmasterClockClass | 0 | 0 | Denotes the traceability of the time or frequency of the grandmaster. The default value is set to ieee8021AsDefaultDSClockClass. |
1.3.111.2.802.1.1.20.1.3.6 | ieee8021AsParentDSGrandmasterClockAccuracy | 0 | 0 | Characterizes the grandmaster clock for the purpose of the best master clock algorithm. The default value is set to ieee8021AsDe… |
1.3.111.2.802.1.1.20.1.3.7 | ieee8021AsParentDSGrandmasterOffsetScaledLogVariance | 0 | 0 | Clock Allan variance of the local clock expressed as a base-2 logarithm multiplied by a scale factor of 256. Hysteresis is applie… |
1.3.111.2.802.1.1.20.1.3.8 | ieee8021AsParentDSGrandmasterPriority1 | 0 | 0 | Grandmaster's most-significant priority declaration in the execution of the best master clock algorithm. Lower values take preced… |
1.3.111.2.802.1.1.20.1.3.9 | ieee8021AsParentDSGrandmasterPriority2 | 0 | 0 | Grandmaster's least-significant priority declaration in the execution of the best master clock algorithm. Lower values take prece… |