Reference record for OID 1.3.111.2.802.1.1.24.1.1.6


parent
1.3.111.2.802.1.1.24.1.1 (ieee8021BridgeEvbSys)
node code
6
node name
ieee8021BridgeEvbSysEcpAckTimer
dot oid
1.3.111.2.802.1.1.24.1.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021BridgeEvbMib(24) ieee8021BridgeEvbObjects(1) ieee8021BridgeEvbSys(1) ieee8021BridgeEvbSysEcpAckTimer(6)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021BridgeEvbMib(24) ieee8021BridgeEvbObjects(1) ieee8021BridgeEvbSys(1) ieee8021BridgeEvbSysEcpAckTimer(6)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021BridgeEvbMib(24) ieee8021BridgeEvbObjects(1) ieee8021BridgeEvbSys(1) ieee8021BridgeEvbSysEcpAckTimer(6)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021BridgeEvbMib(24) ieee8021BridgeEvbObjects(1) ieee8021BridgeEvbSys(1) ieee8021BridgeEvbSysEcpAckTimer(6)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021BridgeEvbMib(24) ieee8021BridgeEvbObjects(1) ieee8021BridgeEvbSys(1) ieee8021BridgeEvbSysEcpAckTimer(6)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021BridgeEvbMib(24) ieee8021BridgeEvbObjects(1) ieee8021BridgeEvbSys(1) ieee8021BridgeEvbSysEcpAckTimer(6)}
  • iri oid
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021BridgeEvbMib/ieee8021BridgeEvbObjects/ieee8021BridgeEvbSys/ieee8021BridgeEvbSysEcpAckTimer
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021BridgeEvbMib/ieee8021BridgeEvbObjects/ieee8021BridgeEvbSys/ieee8021BridgeEvbSysEcpAckTimer
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021BridgeEvbMib/ieee8021BridgeEvbObjects/ieee8021BridgeEvbSys/ieee8021BridgeEvbSysEcpAckTimer
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021BridgeEvbMib/ieee8021BridgeEvbObjects/ieee8021BridgeEvbSys/ieee8021BridgeEvbSysEcpAckTimer
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021BridgeEvbMib/ieee8021BridgeEvbObjects/ieee8021BridgeEvbSys/ieee8021BridgeEvbSysEcpAckTimer
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021BridgeEvbMib/ieee8021BridgeEvbObjects/ieee8021BridgeEvbSys/ieee8021BridgeEvbSysEcpAckTimer
  • iri by oid_info
    /ISO/Identified-Organization/111/2/802/1/1/24/1/1/6

    Description by oid_info

    ieee8021BridgeEvbSysEcpAckTimer OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "A value indicating the Bridge Proposed ECP ackTimer."
    REFERENCE
    "D.2.13.6, 43.3.6.1"

    View at oid-info.com

    Description by ieee802

    A value indicating the Bridge Proposed ECP ackTimer.

    Information by oid_info

    Automatically extracted from IEEE Management Information Bases (MIBs).

    Information by ieee802

    ieee8021BridgeEvbSysEcpAckTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "A value indicating the Bridge Proposed ECP ackTimer." REFERENCE "D.2.13.6, 43.3.6.1" ::= { ieee8021BridgeEvbSys 6 }

    Current Registration Authority (recovered by parent 1.3)

    Frank Farance

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.111.2.802.1.1.24.1.1.1 ieee8021BridgeEvbSysType 6 6 The evbSysType determines if this is an EVB Bridge
    or EVB station.
    1.3.111.2.802.1.1.24.1.1.2 ieee8021BridgeEvbSysNumExternalPorts 0 0 The evbSysNumExternalPorts parameter indicates how
    many externally accessible port are available.
    1.3.111.2.802.1.1.24.1.1.3 ieee8021BridgeEvbSysEvbLldpTxEnable 0 0 This object is used to initialize the LLDP EVB
    objects for new SBPs and URPS.
    When set to 'true' a new SBP or URP will place the …
    1.3.111.2.802.1.1.24.1.1.4 ieee8021BridgeEvbSysEvbLldpManual 0 0 This object is used to initialize the LLDP EVB
    objects for new SBPs and URPS.
    When set to 'false' the operating configuration
    will…
    1.3.111.2.802.1.1.24.1.1.5 ieee8021BridgeEvbSysEvbLldpGidCapable 0 0 The value of this object is used as the default
    value of the BGID or SGID bit of the EVB LLDP TLV string.
    1.3.111.2.802.1.1.24.1.1.7 ieee8021BridgeEvbSysEcpMaxRetries 0 0 A value indicating the Bridge ECP maxRetries.
    1.3.111.2.802.1.1.24.1.1.8 ieee8021BridgeEvbSysVdpDfltRsrcWaitDelay 0 0 A value indicating the Bridge Resource VDP Timeout.
    1.3.111.2.802.1.1.24.1.1.9 ieee8021BridgeEvbSysVdpDfltReinitKeepAlive 0 0 A value indicating the Bridge Proposed VDP Keep Alive Timeout.
    1.3.111.2.802.1.1.24.1.1.10 ieee8021BridgeEvbSbpTable 1 9 A table that contains Station-facing Bridge Port (SBP)
    details.
    1.3.111.2.802.1.1.24.1.1.11 ieee8021BridgeEvbSysEcpDfltAckTimerExp 0 0 The exponent of 2 indicating the Bridge Proposed ECP ackTimer
    in tens of microseconds.
    1.3.111.2.802.1.1.24.1.1.12 ieee8021BridgeEvbSysVdpDfltRsrcWaitDelayExp 0 0 The exponent of 2 indicating the Bridge Resource VDP
    Timeout in tens of microseconds.
    1.3.111.2.802.1.1.24.1.1.13 ieee8021BridgeEvbSysVdpDfltReinitKeepAliveExp 0 0 The exponent of 2 indicating the Bridge Proposed VDP Keep
    Alive Timeout in tens of microseconds.