docsIfBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that implement
MCNS/DOCSIS compliant Radio Frequency Interfaces."
MODULE -- docsIfMib
-- unconditionally mandatory groups
MANDATORY-GROUPS {
docsIfBasicGroup
}
-- conditionally mandatory group
GROUP docsIfCmGroup
DESCRIPTION
"This group is implemented only in Cable Modems, not in
Cable Modem Termination Systems."
-- conditionally mandatory group
GROUP docsIfCmtsGroup
DESCRIPTION
"This group is implemented only in Cable Modem Termination
Systems, not in Cable Modems."
OBJECT docsIfDownChannelFrequency
WRITE-SYNTAX Integer32 (54000000..860000000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems. The values above are
appropriate for a cable plant using a Sub-Split channel
plan. If DOCSIS is extended to cover other types of
channel plans (and frequency allocations) this object
will be modified accordingly."
OBJECT docsIfDownChannelWidth
WRITE-SYNTAX Integer32 (6000000)
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only.
In Cable Modems, this object is always implemented as
read-only. The above value is appropriate for cable
plants running under NTSC (National Television
Standards Committee) standards. If DOCSIS is extended to
work with other standard (e.g. European standards), this
object will be modified accordingly."
OBJECT docsIfDownChannelModulation
WRITE-SYNTAX INTEGER {
qam64 (3),
qam256 (4)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfDownChannelInterleave
WRITE-SYNTAX INTEGER {
taps8Increment16(3),
taps16Increment8(4),
taps32Increment4(5),
taps64Increment2(6),
taps128Increment1(7)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfDownChannelPower
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelFrequency
WRITE-SYNTAX Integer32 (5000000..42000000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems.The values above are
appropriate for a cable plant using a Sub-Split channel
plan. If DOCSIS is extended to cover other types of
channel plans (and frequency allocations) this object
will be modified accordingly."
OBJECT docsIfUpChannelWidth
WRITE-SYNTAX Integer32 (200000..3200000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems.The above value is appropriate
for cable plants running under NTSC (National Television
Standards Committee) standards. If DOCSIS is extended to
work with other standard (e.g. European standards), this
object will be modified accordingly."
OBJECT docsIfUpChannelModulationProfile
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelSlotSize
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfUpChannelRangingBackoffStart
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelRangingBackoffEnd
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelTxBackoffStart
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelTxBackoffEnd
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfQosProfPriority
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxUpBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfGuarUpBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxDownBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxTxBurst
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfBaselinePrivacy
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfStatus
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfCmtsServiceAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsSyncInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsUcdInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsInsertInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsInvitedRangingAttempts
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsQosProfilePermissions
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsModType
WRITE-SYNTAX INTEGER {
qpsk (2),
qam16 (3)
}
DESCRIPTION
"Management station may only set 16QAM or QPSK modulation,
but others might be possible based on device configuration."
View at oid-info.com
The compliance statement for devices that implement
MCNS/DOCSIS compliant Radio Frequency Interfaces.
Parsed from file DOCS-IF-MIB.txt
Company: None
Module: DOCS-IF-MIB
The compliance statement for devices that implement
DOCSIS 1.x compliant Radio Frequency Interfaces.
docsIfBasicCompliance OBJECT IDENTIFIER ::= { docsIfCompliances 1 }
docsIfBasicCompliance OBJECT IDENTIFIER ::= { docsIfCompliances 1 }
Automatically extracted from RFC2670
docsIfBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices that implement MCNS/DOCSIS compliant Radio Frequency Interfaces." MODULE MANDATORY-GROUPS { docsIfBasicGroup } GROUP docsIfCmGroup DESCRIPTION "This group is implemented only in Cable Modems, not in Cable Modem Termination Systems." GROUP docsIfCmtsGroup DESCRIPTION "This group is implemented only in Cable Modem Termination Systems, not in Cable Modems." OBJECT docsIfDownChannelFrequency WRITE-SYNTAX Integer32 (54000000..860000000) MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems. The values above are appropriate for a cable plant using a Sub-Split channel plan. If DOCSIS is extended to cover other types of channel plans (and frequency allocations) this object will be modified accordingly." OBJECT docsIfDownChannelWidth WRITE-SYNTAX Integer32 (6000000) MIN-ACCESS read-only DESCRIPTION "It is conformant to implement this object as read-only. In Cable Modems, this object is always implemented as read-only. The above value is appropriate for cable plants running under NTSC (National Television Standards Committee) standards. If DOCSIS is extended to work with other standard (e.g. European standards), this object will be modified accordingly." OBJECT docsIfDownChannelModulation WRITE-SYNTAX INTEGER { qam64 (3), qam256 (4) } MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfDownChannelInterleave WRITE-SYNTAX INTEGER { taps8Increment16(3), taps16Increment8(4), taps32Increment4(5), taps64Increment2(6), taps128Increment1(7) } MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfDownChannelPower MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfUpChannelFrequency WRITE-SYNTAX Integer32 (5000000..42000000) MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems.The values above are appropriate for a cable plant using a Sub-Split channel plan. If DOCSIS is extended to cover other types of channel plans (and frequency allocations) this object will be modified accordingly." OBJECT docsIfUpChannelWidth WRITE-SYNTAX Integer32 (200000..3200000) MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems.The above value is appropriate for cable plants running under NTSC (National Television Standards Committee) standards. If DOCSIS is extended to work with other standard (e.g. European standards), this object will be modified accordingly." OBJECT docsIfUpChannelModulationProfile MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfUpChannelSlotSize MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfUpChannelRangingBackoffStart MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfUpChannelRangingBackoffEnd MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfUpChannelTxBackoffStart MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfUpChannelTxBackoffEnd MIN-ACCESS read-only DESCRIPTION "Read-write in Cable Modem Termination Systems; read-only in Cable Modems." OBJECT docsIfQosProfPriority MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfQosProfMaxUpBandwidth MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfQosProfGuarUpBandwidth MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfQosProfMaxDownBandwidth MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfQosProfMaxTxBurst MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfQosProfBaselinePrivacy MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfQosProfStatus MIN-ACCESS read-only DESCRIPTION "This object is always read-only in Cable Modems. It is compliant to implement this object as read-only in Cable Modem Termination Systems." OBJECT docsIfCmtsServiceAdminStatus MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsSyncInterval MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsUcdInterval MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsInsertInterval MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsInvitedRangingAttempts MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsQosProfilePermissions MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsModType WRITE-SYNTAX INTEGER { qpsk (2), qam16 (3) } DESCRIPTION "Management station may only set 16QAM or QPSK modulation, but others might be possible based on device configuration." ::= { docsIfCompliances 1 }
docsIfBasicCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for devices that implement DOCSIS 1.x compliant Radio Frequency Interfaces." MODULE MANDATORY-GROUPS { docsIfBasicGroup } GROUP docsIfCmGroup DESCRIPTION "This group is implemented only in cable modems, not in cable modem termination systems." GROUP docsIfCmtsGroup DESCRIPTION "This group is implemented only in cable modem termination systems, not in cable modems." OBJECT docsIfDownChannelFrequency WRITE-SYNTAX Integer32 (54000000..860000000) MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems. The values above are appropriate for a cable plant using a Sub-Split channel plan. If DOCSIS is extended to cover other types of channel plans (and frequency allocations), this object will be modified accordingly." OBJECT docsIfDownChannelWidth WRITE-SYNTAX Integer32 (6000000) MIN-ACCESS read-only DESCRIPTION "It is important to implement this object as read-only. In cable modems, this object is always implemented as read-only. The above value is appropriate for cable plants running under NTSC (National Television Standards Committee) standards. If DOCSIS is extended to work with other standards (e.g., European standards), this object will be modified accordingly." OBJECT docsIfDownChannelModulation WRITE-SYNTAX INTEGER { qam64 (3), qam256 (4) } MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfDownChannelInterleave WRITE-SYNTAX INTEGER { taps8Increment16(3), taps16Increment8(4), taps32Increment4(5), taps64Increment2(6), taps128Increment1(7) } MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfDownChannelPower MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfUpChannelFrequency WRITE-SYNTAX Integer32 (5000000..42000000) MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems. The values above are appropriate for a cable plant using a Sub-Split channel plan. If DOCSIS is extended to cover other types of channel plans (and frequency allocations), this object will be modified accordingly." OBJECT docsIfUpChannelWidth WRITE-SYNTAX Integer32 (200000..3200000) MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems. The above value is appropriate for cable plants running under NTSC (National Television Standards Committee) standards. If DOCSIS is extended to work with other standards (e.g., European standards), this object will be modified accordingly." OBJECT docsIfUpChannelModulationProfile MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfUpChannelSlotSize MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfUpChannelRangingBackoffStart MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfUpChannelRangingBackoffEnd MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfUpChannelTxBackoffStart MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfUpChannelTxBackoffEnd MIN-ACCESS read-only DESCRIPTION "Read-write in cable modem termination systems; read-only in cable modems." OBJECT docsIfQosProfPriority MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfQosProfMaxUpBandwidth MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfQosProfGuarUpBandwidth MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfQosProfMaxDownBandwidth MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfQosProfMaxTxBurst MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfQosProfBaselinePrivacy MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfQosProfStatus MIN-ACCESS read-only DESCRIPTION "This object is always read-only in cable modems. It is compliant to implement this object as read-only in cable modem termination systems." OBJECT docsIfCmtsServiceAdminStatus MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsSyncInterval MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsUcdInterval MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsInsertInterval MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsInvitedRangingAttempts MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsQosProfilePermissions WRITE-SYNTAX BITS { createByManagement(0), updateByManagement(1) } MIN-ACCESS read-only DESCRIPTION "It is compliant to implement this object as read-only." OBJECT docsIfCmtsModType WRITE-SYNTAX INTEGER { qpsk (2), qam16 (3) } DESCRIPTION "A management station MAY only set 16QAM or QPSK modulation, but others might be possible, based on device configuration." OBJECT docsIfCmtsModPreambleLen SYNTAX Integer32 (0..1024) DESCRIPTION "The range of the values for this MODULE-COMPLIANCE is 0..1024." OBJECT docsIfCmtsModFECErrorCorrection SYNTAX Integer32 (0..10) DESCRIPTION "The range of the values for this MODULE-COMPLIANCE is 0..10." ::= { docsIfCompliances 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.127.3.1.2 | docsIfBasicComplianceV2 | 0 | 0 | The compliance statement for devices that implement DOCSIS 2.0 Radio Frequency Interfaces. |