optIfOChCurrentStatus OBJECT-TYPE
SYNTAX BITS {
losP(0),
los(1),
oci(2),
ssfP(3),
ssfO(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is applicable when optIfOChDirectionality
has the value sink(1) or bidirectional(3).
In full-capability systems the bit position los(1) is not used.
In reduced-capability systems or at IrDI interfaces only
the bit positions los(1) and ssfP(3) are used."
View at oid-info.com
Indicates the defect condition of the entity, if any.
This object is applicable when optIfOChDirectionality
has the value sink(1) or bidirectional(3).
In full-capability systems the bit position los(1) is not used.
In reduced-capability systems or at IrDI interfaces only
the bit positions los(1) and ssfP(3) are used.
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
Indicates the defect condition of the entity, if any.
This object is applicable when optIfOChDirectionality
has the value sink(1) or bidirectional(3).
In full-capability systems the bit position los(1) is not used.
In reduced-capability systems or at IrDI interfaces only
the bit positions los(1) and ssfP(3) are used.
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfOChCurrentStatus OBJECT-TYPE SYNTAX BITS { losP(0), los(1), oci(2), ssfP(3), ssfO(4), ssf(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the defect condition of the entity, if any. This object is applicable when optIfOChDirectionality has the value sink(1) or bidirectional(3). In full-capability systems the bit position los(1) is not used. In reduced-capability systems or at IrDI interfaces only the bit positions los(1) and ssfP(3) are used." ::= { optIfOChConfigEntry 2 }
optIfOChCurrentStatus OBJECT-TYPE SYNTAX BITS { losP(0), los(1), oci(2), ssfP(3), ssfO(4), ssf(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the defect condition of the entity, if any. This object is applicable when optIfOChDirectionality has the value sink(1) or bidirectional(3). In full-capability systems the bit position los(1) is not used. In reduced-capability systems or at IrDI interfaces only the bit positions los(1) and ssfP(3) are used." ::= { optIfOChConfigEntry 2 }
Internet Assigned Numbers Authority
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.10.133.1.6.1.1.1 | optIfOChDirectionality | 0 | 0 | Indicates the directionality of the entity. |