Reference record for OID 1.3.6.1.2.1.10.166.10.2.1.2



parent
1.3.6.1.2.1.10.166.10.2.1 (mplsLcFrStdCompliances)
node code
2
node name
mplsLcFrStdModuleReadOnlyCompliance
dot oid
1.3.6.1.2.1.10.166.10.2.1.2
type
MODULE-COMPLIANCE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) mplsStdMIB(166) mplsLcFrStdMIB(10) mplsLcFrStdConformance(2) mplsLcFrStdCompliances(1) mplsLcFrStdModuleReadOnlyCompliance(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) mplsStdMIB(166) mplsLcFrStdMIB(10) mplsLcFrStdConformance(2) mplsLcFrStdCompliances(1) mplsLcFrStdModuleReadOnlyCompliance(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) mplsStdMIB(166) mplsLcFrStdMIB(10) mplsLcFrStdConformance(2) mplsLcFrStdCompliances(1) mplsLcFrStdModuleReadOnlyCompliance(2)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) mplsStdMIB(166) mplsLcFrStdMIB(10) mplsLcFrStdConformance(2) mplsLcFrStdCompliances(1) mplsLcFrStdModuleReadOnlyCompliance(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) mplsStdMIB(166) mplsLcFrStdMIB(10) mplsLcFrStdConformance(2) mplsLcFrStdCompliances(1) mplsLcFrStdModuleReadOnlyCompliance(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) mplsStdMIB(166) mplsLcFrStdMIB(10) mplsLcFrStdConformance(2) mplsLcFrStdCompliances(1) mplsLcFrStdModuleReadOnlyCompliance(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/mplsStdMIB/mplsLcFrStdMIB/mplsLcFrStdConformance/mplsLcFrStdCompliances/mplsLcFrStdModuleReadOnlyCompliance
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/mplsStdMIB/mplsLcFrStdMIB/mplsLcFrStdConformance/mplsLcFrStdCompliances/mplsLcFrStdModuleReadOnlyCompliance
  • /iso/org/dod/internet/mgmt/mib-2/transmission/mplsStdMIB/mplsLcFrStdMIB/mplsLcFrStdConformance/mplsLcFrStdCompliances/mplsLcFrStdModuleReadOnlyCompliance
  • /iso/org/dod/internet/mgmt/mib/transmission/mplsStdMIB/mplsLcFrStdMIB/mplsLcFrStdConformance/mplsLcFrStdCompliances/mplsLcFrStdModuleReadOnlyCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/mplsStdMIB/mplsLcFrStdMIB/mplsLcFrStdConformance/mplsLcFrStdCompliances/mplsLcFrStdModuleReadOnlyCompliance
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/mplsStdMIB/mplsLcFrStdMIB/mplsLcFrStdConformance/mplsLcFrStdCompliances/mplsLcFrStdModuleReadOnlyCompliance
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/166/10/2/1/2

    Description by oid_info

    mplsLcFrStdModuleReadOnlyCompliance MODULE-COMPLIANCE
    STATUS current
    DESCRIPTION
    "Compliance requirement for implementations that only
    provide read-only support for MPLS-LC-FR-STD-MIB.
    Such devices can be monitored but cannot be configured
    using this MIB module.
    "
    MODULE -- this module
    MANDATORY-GROUPS {
    mplsLcFrStdIfGroup
    }
    -- mplsLcFrStdInterfaceConftable
    OBJECT mplsLcFrStdTrafficMinDlci
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsLcFrStdTrafficMaxDlci
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsLcFrStdCtrlMinDlci
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsLcFrStdCtrlMaxDlci
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."
    OBJECT mplsLcFrStdInterfaceConfRowStatus
    SYNTAX RowStatus { active(1) }
    MIN-ACCESS read-only
    DESCRIPTION "Write access is not required."
    OBJECT mplsLcFrStdInterfaceConfStorageType
    MIN-ACCESS read-only
    DESCRIPTION
    "Write access is not required."

    View at oid-info.com

    Description by mibdepot

    Compliance requirement for implementations that only
    provide read-only support for MPLS-LC-FR-STD-MIB.
    Such devices can be monitored but cannot be configured
    using this MIB module.

    Parsed from file rfc4368-MPLS-LC-ATM-and-FR-MIBs.mib-2.txt
    Company: None
    Module: MPLS-LC-FR-STD-MIB

    Description by circitor

    Compliance requirement for implementations that only
    provide read-only support for MPLS-LC-FR-STD-MIB.
    Such devices can be monitored but cannot be configured
    using this MIB module.

    Parsed from file MPLS-LC-FR-STD-MIB.mib
    Module: MPLS-LC-FR-STD-MIB

    Information by mibdepot

    mplsLcFrStdModuleReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance requirement for implementations that only provide read-only support for MPLS-LC-FR-STD-MIB. Such devices can be monitored but cannot be configured using this MIB module. " MODULE MANDATORY-GROUPS { mplsLcFrStdIfGroup } OBJECT mplsLcFrStdTrafficMinDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdTrafficMaxDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdCtrlMinDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdCtrlMaxDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdInterfaceConfRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdInterfaceConfStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { mplsLcFrStdCompliances 2 }

    Information by circitor

    mplsLcFrStdModuleReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance requirement for implementations that only provide read-only support for MPLS-LC-FR-STD-MIB. Such devices can be monitored but cannot be configured using this MIB module. " MODULE MANDATORY-GROUPS { mplsLcFrStdIfGroup } OBJECT mplsLcFrStdTrafficMinDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdTrafficMaxDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdCtrlMinDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdCtrlMaxDlci MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdInterfaceConfRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT mplsLcFrStdInterfaceConfStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { mplsLcFrStdCompliances 2 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.166.10.2.1.1 mplsLcFrStdModuleFullCompliance 0 0 Compliance statement for agents that provide
    full support for MPLS-LC-FR-STD-MIB. Such
    devices can be monitored and also be conf…