frnetservCompliance MODULE-COMPLIANCE STATUS deprecated
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Service Interfaces.
This compliance statement has been deprecated in
favor of frnetservCompliance2. The new compliance
module expands the mandatory groups to include
notification and other new objects."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup,
frnetservMgtVCSigGroup,
frnetservPVCEndptGroup,
frnetservPVCConnectGroup }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for Frame Relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this Frame
Relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for Frame Relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this Frame Relay interface."
OBJECT frPVCEndptInMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
OBJECT frPVCConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
View at oid-info.com
The compliance statement for SNMPv2 entities
which have Frame Relay Network Service Interfaces.
Parsed from file rfc1604.mib.txt
Company: None
Module: FRNETSERV-MIB
The compliance statement for SNMP entities which
have Frame Relay Network Service Interfaces.
This compliance statement has been deprecated in
favor of frnetservCompliance2. The new compliance
module expands the mandatory groups to include
notification and other new objects.
Parsed from file FRNETSERV-MIB.mib
Module: FRNETSERV-MIB
Automatically extracted from RFC2954
frnetservCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which have Frame Relay Network Service Interfaces." MODULE MANDATORY-GROUPS { frnetservLportGroup, frnetservMgtVCSigGroup, frnetservPVCEndptGroup, frnetservPVCConnectGroup } GROUP frnetservAccountPVCGroup DESCRIPTION "This group is optional for Frame Relay interfaces. It is mandatory if and only if accounting is performed on a PVC basis this Frame Relay interface." GROUP frnetservAccountLportGroup DESCRIPTION "This group is optional for Frame Relay interfaces. It is mandatory if and only if accounting is performed on a logical port basis this Frame Relay interface." OBJECT frPVCEndptInMaxFrameSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptInBc MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptInBe MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptInCIR MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutMaxFrameSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutBc MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutBe MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutCIR MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptConnectIdentifier DESCRIPTION "Write access is not required." OBJECT frPVCEndptRowStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)." OBJECT frPVCConnectAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCConnectRowStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)." ::= { frnetservCompliances 1 }
frnetservCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for SNMP entities which have Frame Relay Network Service Interfaces. This compliance statement has been deprecated in favor of frnetservCompliance2. The new compliance module expands the mandatory groups to include notification and other new objects." MODULE MANDATORY-GROUPS { frnetservLportGroup, frnetservMgtVCSigGroup, frnetservPVCEndptGroup, frnetservPVCConnectGroup } GROUP frnetservAccountPVCGroup DESCRIPTION "This group is optional for Frame Relay interfaces. It is mandatory if and only if accounting is performed on a PVC basis this Frame Relay interface." GROUP frnetservAccountLportGroup DESCRIPTION "This group is optional for Frame Relay interfaces. It is mandatory if and only if accounting is performed on a logical port basis this Frame Relay interface." OBJECT frPVCEndptInMaxFrameSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptInBc MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptInBe MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptInCIR MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutMaxFrameSize MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutBc MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutBe MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptOutCIR MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCEndptRowStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)." OBJECT frPVCConnectAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT frPVCConnectRowStatus SYNTAX INTEGER { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required, and only one of the six enumerated values for the RowStatus textual convention need be supported, specifically: active(1)." ::= { frnetservCompliances 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.44.3.2.2 | frnetservCompliance2 | 0 | 0 | The compliance statement for SNMP entities which have Frame Relay Network Service Interfaces. The distinction between 'service' a… |
1.3.6.1.2.1.10.44.3.2.3 | frnetSwitchCompliance | 0 | 0 | The compliance statement for SNMP entities which have Frame Relay Network Switch objects. The distinction between 'service' and '… |