An arbitrary integer that uniquely identifies an Nx_Port
amongst all those attached to the Fx_Port indicated by
ifIndex.
After a value of this object is assigned to a particular
Nx_Port, that value can be re-used when and only when it is
assigned to the same Nx_Port, or, after a reset of the value
of the relevant instance of ifCounterDiscontinuityTime.
Parsed from file FC-MGMT-MIB.mib
Module: FC-MGMT-MIB
An arbitrary integer that uniquely identifies an Nx_Port
amongst all those attached to the Fx_Port indicated by
ifIndex.
After a value of this object is assigned to a particular
Nx_Port, that value can be re-used when and only when it is
assigned to the same Nx_Port, or, after a reset of the value
of the relevant instance of ifCounterDiscontinuityTime.
fcmFLoginNxPortIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer that uniquely identifies an Nx_Port
amongst all those attached to the Fx_Port indicated by
ifIndex.
After a value of this object is assigned to a particular
Nx_Port, that value can be re-used when and only when it is
assigned to the same Nx_Port, or, after a reset of the value
of the relevant instance of ifCounterDiscontinuityTime."
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
View at oid-info.com
An arbitrary integer that uniquely identifies an Nx_Port
amongst all those attached to the Fx_Port indicated by
ifIndex.
After a value of this object is assigned to a particular
Nx_Port, that value can be re-used when and only when it is
assigned to the same Nx_Port, or, after a reset of the value
of the relevant instance of ifCounterDiscontinuityTime.
Parsed from file FCMGMT-MIB.mib.txt
Company: None
Module: FC-MGMT-MIB
An arbitrary integer that uniquely identifies an Nx_Port
amongst all those attached to the Fx_Port indicated by
ifIndex.
After a value of this object is assigned to a particular
Nx_Port, that value can be re-used when and only when it is
assigned to the same Nx_Port, or, after a reset of the value
of the relevant instance of ifCounterDiscontinuityTime.
fcmFLoginNxPortIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer that uniquely identifies an Nx_Port amongst all those attached to the Fx_Port indicated by ifIndex. After a value of this object is assigned to a particular Nx_Port, that value can be re-used when and only when it is assigned to the same Nx_Port, or, after a reset of the value of the relevant instance of ifCounterDiscontinuityTime." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." ::= { fcmFLoginEntry 1 }
fcmFLoginNxPortIndex OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS not-accessible STATUS mandatory DESCRIPTION "An arbitrary integer that uniquely identifies an Nx_Port amongst all those attached to the Fx_Port indicated by ifIndex. After a value of this object is assigned to a particular Nx_Port, that value can be re-used when and only when it is assigned to the same Nx_Port, or, after a reset of the value of the relevant instance of ifCounterDiscontinuityTime." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." ::= { fcmFLoginEntry 1 }
Automatically extracted from RFC4044
fcmFLoginNxPortIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer that uniquely identifies an Nx_Port amongst all those attached to the Fx_Port indicated by ifIndex. After a value of this object is assigned to a particular Nx_Port, that value can be re-used when and only when it is assigned to the same Nx_Port, or, after a reset of the value of the relevant instance of ifCounterDiscontinuityTime." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." ::= { fcmFLoginEntry 1 }
fcmFLoginNxPortIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer that uniquely identifies an Nx_Port amongst all those attached to the Fx_Port indicated by ifIndex. After a value of this object is assigned to a particular Nx_Port, that value can be re-used when and only when it is assigned to the same Nx_Port, or, after a reset of the value of the relevant instance of ifCounterDiscontinuityTime." REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000." ::= { fcmFLoginEntry 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.56.1.9.1.2 | fcmFLoginPortWwn | 0 | 0 | The port name of the attached Nx_Port, or the zero-length string if unknown. |
1.3.6.1.2.1.10.56.1.9.1.3 | fcmFLoginNodeWwn | 0 | 0 | The node name of the attached Nx_Port, or the zero-length string if unknown. |
1.3.6.1.2.1.10.56.1.9.1.4 | fcmFLoginBbCreditModel | 0 | 0 | The buffer-to-buffer credit model in use by the Fx_Port. |
1.3.6.1.2.1.10.56.1.9.1.5 | fcmFLoginBbCredit | 0 | 0 | The number of buffers available for holding frames to be transmitted to the attached Nx_Port. These buffers are for buffer-to-bu… |
1.3.6.1.2.1.10.56.1.9.1.6 | fcmFLoginClassesAgreed | 0 | 0 | The Classes of Service that the Fx_Port has agreed to support for this Nx_Port. |
1.3.6.1.2.1.10.56.1.9.1.7 | fcmFLoginClass2SeqDelivAgreed | 0 | 0 | An indication of whether the Fx_Port has agreed to support Class 2 sequential delivery for this Nx_Port. This is only meaningful… |
1.3.6.1.2.1.10.56.1.9.1.8 | fcmFLoginClass2DataFieldSize | 0 | 0 | The Receive Data Field Size that the Fx_Port has agreed to support for Class 2 frames to/from this Nx_Port. The size specifies t… |
1.3.6.1.2.1.10.56.1.9.1.9 | fcmFLoginClass3SeqDelivAgreed | 0 | 0 | An indication of whether the Fx_Port has agreed to support Class 3 sequential delivery for this Nx_Port. This is only meaningful… |
1.3.6.1.2.1.10.56.1.9.1.10 | fcmFLoginClass3DataFieldSize | 0 | 0 | The Receive Data Field Size that the Fx_Port has agreed to support for Class 3 frames to/from this Nx_Port. The size specifies t… |