Reference record for OID 1.3.6.1.2.1.16.3.1.1.1


parent
1.3.6.1.2.1.16.3.1.1 (alarmEntry)
node code
1
node name
alarmIndex
dot oid
1.3.6.1.2.1.16.3.1.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) alarm(3) alarmTable(1) alarmEntry(1) alarmIndex(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) alarm(3) alarmTable(1) alarmEntry(1) alarmIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) alarm(3) alarmTable(1) alarmEntry(1) alarmIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) alarm(3) alarmTable(1) alarmEntry(1) alarmIndex(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) rmon(16) alarm(3) alarmTable(1) alarmEntry(1) alarmIndex(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) rmon(16) alarm(3) alarmTable(1) alarmEntry(1) alarmIndex(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/rmon/alarm/alarmTable/alarmEntry/alarmIndex
  • /iso/identified-organization/dod/internet/mgmt/mib/rmon/alarm/alarmTable/alarmEntry/alarmIndex
  • /iso/org/dod/internet/mgmt/mib-2/rmon/alarm/alarmTable/alarmEntry/alarmIndex
  • /iso/org/dod/internet/mgmt/mib/rmon/alarm/alarmTable/alarmEntry/alarmIndex
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/rmon/alarm/alarmTable/alarmEntry/alarmIndex
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/rmon/alarm/alarmTable/alarmEntry/alarmIndex
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/16/3/1/1/1

    Description by circitor

    An index that uniquely identifies an entry in the
    alarm table. Each such entry defines a
    diagnostic sample at a particular interval
    for an object on the device.

    Parsed from file ITOUCHHUB.mib
    Module: ITOUCHHUB

    Description by cisco_v1

    An index that uniquely identifies an entry in the
    alarm table. Each such entry defines a
    diagnostic sample at a particular interval
    for an object on the device.

    Description by oid_info

    alarmIndex OBJECT-TYPE
    SYNTAX INTEGER (1..65535)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "An index that uniquely identifies an entry in the
    alarm table. Each such entry defines a
    diagnostic sample at a particular interval
    for an object on the device."

    View at oid-info.com

    Description by mibdepot

    An index that uniquely identifies an entry in the
    alarm table. Each such entry defines a
    diagnostic sample at a particular interval
    for an object on the device.

    Parsed from file lbhub-fms.mib.txt
    Company: None
    Module: LBHUB-FMS-MIB

    Description by cisco

    An index that uniquely identifies an entry in the
    alarm table. Each such entry defines a
    diagnostic sample at a particular interval
    for an object on the device.

    Information by circitor

    alarmIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { alarmEntry 1 }

    Information by cisco_v1

    alarmIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { alarmEntry 1 }

    Information by oid_info

    Automatically extracted from rfc1757

    Information by mibdepot

    alarmIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { alarmEntry 1 }

    Information by cisco

    alarmIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { alarmEntry 1 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Children (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.16.3.1.1.1.0 alarmFallingEventIndex 0 0 alarmFallingEventIndex OBJECT-TYPE
    SYNTAX INTEGER (0..65535)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The index of the e…
    1.3.6.1.2.1.16.3.1.1.1.1 alarmOwner 0 0 alarmOwner OBJECT-TYPE
    SYNTAX OwnerString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The entity that configured this entry…
    1.3.6.1.2.1.16.3.1.1.1.2 alarmStatus 0 0 alarmStatus OBJECT-TYPE
    SYNTAX EntryStatus
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The status of this alarm entry."

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.16.3.1.1.2 alarmInterval 0 0 The interval in seconds over which the data is
    sampled and compared with the rising and falling
    thresholds. When setting this va…
    1.3.6.1.2.1.16.3.1.1.3 alarmVariable 0 0 The object identifier of the particular variable to
    be sampled. Only variables that resolve to an ASN.1
    primitive type of INTEGE…
    1.3.6.1.2.1.16.3.1.1.4 alarmSampleType 0 0 The method of sampling the selected variable and
    calculating the value to be compared against the
    thresholds. If the value of th…
    1.3.6.1.2.1.16.3.1.1.5 alarmValue 0 0 The value of the statistic during the last sampling
    period. The value during the current sampling period
    is not made available u…
    1.3.6.1.2.1.16.3.1.1.6 alarmStartupAlarm 0 0 The alarm that may be sent when this entry is first
    set to valid. If the first sample after this entry
    becomes valid is greater …
    1.3.6.1.2.1.16.3.1.1.7 alarmRisingThreshold 0 0 A threshold for the sampled statistic. When the current
    sampled value is greater than or equal to this threshold,
    and the value …
    1.3.6.1.2.1.16.3.1.1.8 alarmFallingThreshold 0 0 A threshold for the sampled statistic. When the current
    sampled value is less than or equal to this threshold,
    and the value at …
    1.3.6.1.2.1.16.3.1.1.9 alarmRisingEventIndex 0 0 The index of the eventEntry that is
    used when a rising threshold is crossed. The
    eventEntry identified by a particular value of
    t…
    1.3.6.1.2.1.16.3.1.1.10 alarmFallingEventIndex 0 0 The index of the eventEntry that is
    used when a falling threshold is crossed. The
    eventEntry identified by a particular value of…
    1.3.6.1.2.1.16.3.1.1.11 alarmOwner 0 0 The entity that configured this entry and is
    therefore using the resources assigned to it.
    1.3.6.1.2.1.16.3.1.1.12 alarmStatus 0 0 The status of this alarm entry.