t11FcsIeEntry OBJECT-TYPE
SYNTAX T11FcsIeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about an Interconnect Element that was
discovered on a Fabric (identified by t11FcsFabricIndex),
by a switch (identified by fcmInstanceIndex and
fcmSwitchIndex)."
REFERENCE
"ANSI INCITS 427-2007, Fibre Channel - Generic Services 5,
FC-GS-5, section 6.2.3.2."
INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcsFabricIndex,
t11FcsIeName }
View at oid-info.com
Information about an Interconnect Element that was
discovered on a Fabric (identified by t11FcsFabricIndex),
by a switch (identified by fcmInstanceIndex and
fcmSwitchIndex).
Parsed from file rfc4935-Fibre-Channel-Fabric-Configuration-Server.mib.txt
Company: None
Module: T11-FC-FABRIC-CONFIG-SERVER-MIB
Information about an Interconnect Element that was
discovered on a Fabric (identified by t11FcsFabricIndex),
by a switch (identified by fcmInstanceIndex and
fcmSwitchIndex).
Parsed from file T11-FC-FABRIC-CONFIG-SERVER-MIB.mib
Module: T11-FC-FABRIC-CONFIG-SERVER-MIB
Automatically extracted from RFC4935
t11FcsIeEntry OBJECT-TYPE SYNTAX T11FcsIeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about an Interconnect Element that was discovered on a Fabric (identified by t11FcsFabricIndex), by a switch (identified by fcmInstanceIndex and fcmSwitchIndex)." REFERENCE "ANSI INCITS 427-2007, Fibre Channel - Generic Services 5, FC-GS-5, section 6.2.3.2." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcsFabricIndex, t11FcsIeName } ::= { t11FcsIeTable 1 }
t11FcsIeEntry OBJECT-TYPE SYNTAX T11FcsIeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about an Interconnect Element that was discovered on a Fabric (identified by t11FcsFabricIndex), by a switch (identified by fcmInstanceIndex and fcmSwitchIndex)." REFERENCE "ANSI INCITS 427-2007, Fibre Channel - Generic Services 5, FC-GS-5, section 6.2.3.2." INDEX { fcmInstanceIndex, fcmSwitchIndex, t11FcsFabricIndex, t11FcsIeName } ::= { t11FcsIeTable 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.162.1.2.1.1.1 | t11FcsIeName | 0 | 0 | The WWN of an Interconnect Element. This object uniquely identifies an Interconnect Element on a Fabric. If the IE is a switch,… |
1.3.6.1.2.1.162.1.2.1.1.2 | t11FcsIeType | 0 | 0 | The type of this Interconnect Element. |
1.3.6.1.2.1.162.1.2.1.1.3 | t11FcsIeDomainId | 0 | 0 | The Domain ID of this Interconnect Element. |
1.3.6.1.2.1.162.1.2.1.1.4 | t11FcsIeMgmtId | 0 | 0 | The management identifier of this Interconnect Element. If the Interconnect Element is a switch, this object will be the Domain C… |
1.3.6.1.2.1.162.1.2.1.1.5 | t11FcsIeFabricName | 0 | 0 | The Fabric_Name (WWN) of this Interconnect Element. When the Fabric_Name is unknown, this object contains the all-zeros value: x'… |
1.3.6.1.2.1.162.1.2.1.1.6 | t11FcsIeLogicalName | 0 | 0 | The logical name of this Interconnect Element. When the logical name is unknown, this object contains the zero-length string. |
1.3.6.1.2.1.162.1.2.1.1.7 | t11FcsIeMgmtAddrListIndex | 0 | 0 | The management address list for this Interconnect Element. This object points to an entry in the t11FcsMgmtAddrListTable. |
1.3.6.1.2.1.162.1.2.1.1.8 | t11FcsIeInfoList | 0 | 0 | The information list for this Interconnect Element. The value of this object is formatted as specified in FC-GS-5, i.e., it has t… |