The amount of time a connection must have had no traffic on it in order for a TIMING-MARK or NOP request to be sent on the connection. This value applies only when connections are being examined for recent activity on a scan interval controlled by the value of the tn3270eSrvrConfTmNopInterval object.
Definitions may combine these properties differently.
Compare 4 source variants
Variant 1 — MIBdepot
Value type
UInteger32
Units
seconds
Maximum access defined by MIB
read-create
Status in MIB
current
Default value
600
Allowed ranges
1–99999999
Variant 2 — Cisco, Circitor
Value type
Unsigned32
Units
seconds
Maximum access defined by MIB
read-create
Status in MIB
current
Default value
600
Allowed ranges
1–86400
Variant 3 — Cisco SMIv1
Value type
Gauge
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
600
Allowed ranges
1–86400
Variant 4 — MIBdepot
Value type
UInteger32
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
600
Allowed ranges
1–99999999
Using this OID with SNMP
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In TN3270E-MIB, the row index tn3270eSrvrConfIndex is declared as Unsigned32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.2.1.34.8.1.1.1.4.<tn3270eSrvrConfIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
tn3270eSrvrConfActivityTimeout OBJECT-TYPE
SYNTAX UInteger32 (1..99999999)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The TIMEMARK or NOP processing time-out specified in seconds.
Note that a value of 0 is not allowed for this object since
the function that uses this object relies on
tn3270eSrvrConfActivityCheck for function enablement."
DEFVAL { 600 } -- 10 minutes
::= { tn3270eSrvrConfEntry 4 }
Meaning
Descriptions
3 unique
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The amount of time a connection must have had no traffic on it in order for a TIMING-MARK or NOP request to be sent on the connection. This value applies only when connections are being examined for recent activity on a scan interval controlled by the value of the tn3270eSrvrConftmNopInterval object.
Original text from OID Repository
tn3270eSrvrConftmNopInactTime OBJECT-TYPE
SYNTAX Unsigned32 (1..86400) -- 1 second to 24 hours
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount of time a connection must have had no
traffic on it in order for a TIMING-MARK or NOP request
to be sent on the connection. This value applies only
when connections are being examined for recent activity
on a scan interval controlled by the value of the
tn3270eSrvrConftmNopInterval object."
DEFVAL { 600 } -- 10 minutes
The amount of time a connection must have had no traffic on it in order for a TIMING-MARK or NOP request to be sent on the connection. This value applies only when connections are being examined for recent activity on a scan interval controlled by the value of the tn3270eSrvrConfTmNopInterval object.
The TIMEMARK or NOP processing time-out specified in seconds. Note that a value of 0 is not allowed for this object since the function that uses this object relies on tn3270eSrvrConfActivityCheck for function enablement.
tn3270eSrvrConfTmNopInactTime OBJECT-TYPE
SYNTAX Unsigned32 (1..86400)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount of time a connection must have had no
traffic on it in order for a TIMING-MARK or NOP request
to be sent on the connection. This value applies only
when connections are being examined for recent activity
on a scan interval controlled by the value of the
tn3270eSrvrConfTmNopInterval object."
DEFVAL { 600 }
::= { tn3270eSrvrConfEntry 4 }
Information from Cisco SMIv1
tn3270eSrvrConfTmNopInactTime OBJECT-TYPE
SYNTAX Gauge(1..86400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time a connection must have had no
traffic on it in order for a TIMING-MARK or NOP request
to be sent on the connection. This value applies only
when connections are being examined for recent activity
on a scan interval controlled by the value of the
tn3270eSrvrConfTmNopInterval object."
DEFVAL { 600 }
::= { tn3270eSrvrConfEntry 4 }
Information from MIBdepot
tn3270eSrvrConfActivityTimeout OBJECT-TYPE
SYNTAX UInteger32(1..99999999)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TIMEMARK or NOP processing time-out specified in seconds.
Note that a value of 0 is not allowed for this object since
the function that uses this object relies on
tn3270eSrvrConfActivityCheck for function enablement."
DEFVAL { 600 }
::= { tn3270eSrvrConfEntry 4 }
Information from Cisco
tn3270eSrvrConfTmNopInactTime OBJECT-TYPE
SYNTAX Unsigned32 (1..86400)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount of time a connection must have had no
traffic on it in order for a TIMING-MARK or NOP request
to be sent on the connection. This value applies only
when connections are being examined for recent activity
on a scan interval controlled by the value of the
tn3270eSrvrConfTmNopInterval object."
DEFVAL { 600 }
::= { tn3270eSrvrConfEntry 4 }
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6)