flowReaderTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the maximum time (in seconds) between flow data
collections for this meter reader. If this time elapses
without a collection, the meter should assume that this meter
reader has stopped collecting, and delete this row from the
table. A value of zero indicates that this row should not be
timed out."
View at oid-info.com
Specifies the maximum time (in seconds) between flow data
collections for this meter reader. If this time elapses
without a collection, the meter should assume that this meter
reader has stopped collecting, and delete this row from the
table. A value of zero indicates that this row should not be
timed out.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
Specifies the maximum time (in seconds) between flow data
collections for this meter reader. If this time elapses
without a collection, the meter should assume that this meter
reader has stopped collecting, and delete this row from the
table. A value of zero indicates that this row should not be
timed out.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowReaderTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the maximum time (in seconds) between flow data collections for this meter reader. If this time elapses without a collection, the meter should assume that this meter reader has stopped collecting, and delete this row from the table. A value of zero indicates that this row should not be timed out." ::= { flowReaderInfoEntry 2 }
flowReaderTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the maximum time (in seconds) between flow data collections for this meter reader. If this time elapses without a collection, the meter should assume that this meter reader has stopped collecting, and delete this row from the table. A value of zero indicates that this row should not be timed out." ::= { flowReaderInfoEntry 2 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.3.1.1 | flowReaderIndex | 0 | 0 | An index which selects an entry in the flowReaderInfoTable. |
1.3.6.1.2.1.40.1.3.1.3 | flowReaderOwner | 0 | 0 | Identifies the meter reader which created this row. |
1.3.6.1.2.1.40.1.3.1.4 | flowReaderLastTime | 0 | 0 | Time this meter reader began its most recent data collection. This variable should be written by a meter reader as its first step… |
1.3.6.1.2.1.40.1.3.1.5 | flowReaderPreviousTime | 0 | 0 | Time this meter reader began the collection before last. |
1.3.6.1.2.1.40.1.3.1.6 | flowReaderStatus | 0 | 0 | The status of this FlowReaderInfoEntry. A value of active(1) implies that the associated reader should be collecting data from th… |
1.3.6.1.2.1.40.1.3.1.7 | flowReaderRuleSet | 0 | 0 | An index to the array of RuleSets. Specifies a set of rules of interest to this meter reader. The reader will attempt to collec… |