dot4Commands OBJECT-TYPE
SYNTAX INTEGER {
no-op(1),
enterRing(2),
exitRing(3),
reset(4),
initialize(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object causes the station
to change the state of the interface as
indicated by the specified value. An
initialize(5) command causes the
interfaceto load its operational
parameters from its initialization
parameters; the value of
dot4InitInRingDesired determines
whether the station tries to enter the
logical ring immediately.
Note that the 802.4 specification
suggests a station remain Offline after a
emote Network Management reset(4),
until a local Network Management
initialize(5) is performed.
Setting this object to a value of
no-op(1) has no effect. When read,
this object always has the value no-op(1)."
View at oid-info.com
Setting this object causes the station
to change the state of the interface as
indicated by the specified value. An
initialize(5) command causes the
interfaceto load its operational
parameters from its initialization
parameters; the value of
dot4InitInRingDesired determines
whether the station tries to enter the
logical ring immediately.
Note that the 802.4 specification
suggests a station remain Offline after a
'remote Network Management' reset(4),
until a 'local Network Management'
initialize(5) is performed.
Setting this object to a value of
no-op(1) has no effect. When read,
this object always has the value no-op(1).
Parsed from file rfc1230-IEEE-802.4-Token-Bus.mib.txt
Company: None
Module: RFC1230-MIB
Setting this object causes the station
to change the state of the interface as
indicated by the specified value. An
initialize(5) command causes the
interfaceto load its operational
parameters from its initialization
parameters; the value of
dot4InitInRingDesired determines
whether the station tries to enter the
logical ring immediately.
Note that the 802.4 specification
suggests a station remain Offline after a
'remote Network Management' reset(4),
until a 'local Network Management'
initialize(5) is performed.
Setting this object to a value of
no-op(1) has no effect. When read,
this object always has the value no-op(1).
Parsed from file RFC1230-MIB.mib
Module: RFC1230-MIB
Automatically extracted from RFC1230
dot4Commands OBJECT-TYPE SYNTAX INTEGER { no-op(1), enterRing(2), exitRing(3), reset(4), initialize(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object causes the station to change the state of the interface as indicated by the specified value. An initialize(5) command causes the interfaceto load its operational parameters from its initialization parameters; the value of dot4InitInRingDesired determines whether the station tries to enter the logical ring immediately. Note that the 802.4 specification suggests a station remain Offline after a 'remote Network Management' reset(4), until a 'local Network Management' initialize(5) is performed. Setting this object to a value of no-op(1) has no effect. When read, this object always has the value no-op(1)." ::= { dot4Entry 4 }
dot4Commands OBJECT-TYPE SYNTAX INTEGER { no-op(1), enterRing(2), exitRing(3), reset(4), initialize(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object causes the station to change the state of the interface as indicated by the specified value. An initialize(5) command causes the interfaceto load its operational parameters from its initialization parameters; the value of dot4InitInRingDesired determines whether the station tries to enter the logical ring immediately. Note that the 802.4 specification suggests a station remain Offline after a 'remote Network Management' reset(4), until a 'local Network Management' initialize(5) is performed. Setting this object to a value of no-op(1) has no effect. When read, this object always has the value no-op(1)." ::= { dot4Entry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.3.7.1.1.1 | dot4IfIndex | 0 | 0 | The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this o… |
1.3.6.1.3.7.1.1.2 | dot4Options | 0 | 0 | The optional parts of the 802.4 specification which are in use by this station. The options of the 802.4 specification are repres… |
1.3.6.1.3.7.1.1.3 | dot4State | 0 | 0 | The current state of the 802.4 interface. The value of other(1) is used if the state is unknown (e.g., due to an error condition). |
1.3.6.1.3.7.1.1.5 | dot4MacAddrLen | 0 | 0 | This object indicates the size of MAC addresses interpreted by this station. |
1.3.6.1.3.7.1.1.6 | dot4NextStation | 0 | 0 | The MAC address of this station's successor in the logical ring. |
1.3.6.1.3.7.1.1.7 | dot4PreviousStation | 0 | 0 | The source MAC address of the last token addressed to this station. |
1.3.6.1.3.7.1.1.8 | dot4SlotTime | 0 | 0 | The maximum time any station need wait for an immediate MAC-level response from another station. This value must the same in all s… |
1.3.6.1.3.7.1.1.9 | dot4LastTokenRotTime | 0 | 0 | The observed token rotation time for the last token rotation, timed from token arrival to token arrival. A value of zero indicate… |
1.3.6.1.3.7.1.1.10 | dot4HiPriTokenHoldTime | 0 | 0 | The maximum duration for which a station can hold the token to transmit frames of access class 6 (if the priority option is implem… |
1.3.6.1.3.7.1.1.11 | dot4TargetRotTimeClass4 | 0 | 0 | If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 4. T… |
1.3.6.1.3.7.1.1.12 | dot4TargetRotTimeClass2 | 0 | 0 | If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 2. T… |
1.3.6.1.3.7.1.1.13 | dot4TargetRotTimeClass0 | 0 | 0 | If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 0. T… |
1.3.6.1.3.7.1.1.14 | dot4TargetRotTimeRingMaint | 0 | 0 | A value used to limit the duration of a token rotation. If the duration of a token rotation exceeds this value, the station will … |
1.3.6.1.3.7.1.1.15 | dot4RingMaintTimerInitValue | 0 | 0 | The value to which the dot4TargetRotTimeRingMaint is set, each time the station enters the ring. A large value will cause the stat… |
1.3.6.1.3.7.1.1.16 | dot4MaxInterSolicitCount | 0 | 0 | The maximum number of consecutive token rotations without soliciting for a successor. If this count expires, the station opens th… |
1.3.6.1.3.7.1.1.17 | dot4MaxRetries | 0 | 0 | The maximum number of retries of a Request-with-Response (RWR) frame. If the RWR option is not in use, this object has the value … |
1.3.6.1.3.7.1.1.18 | dot4MinPostSilencePreambLen | 0 | 0 | The minimum number of octets of preamble on the first frame transmitted by this station after a period of 'transmitted' silence. |
1.3.6.1.3.7.1.1.19 | dot4StandardRevision | 0 | 0 | The Revision number of the 802.4 standard implemented by this station. |