This value defines the event severity
that will be logged by this connectivity unit.
All events of severity less than or equal to
connUnitEventFilter are logged in connUnitEventTable.
Persistent across boots.
Parsed from file FCMGMT-MIB.mib
Module: FCMGMT-MIB
This value defines the event severity
that will be logged by this connectivity unit.
All events of severity less than or equal to
connUnitEventFilter are logged in connUnitEventTable.
Persistent across boots.
This value defines the event severity
that will be logged by this connectivity unit.
All events of severity less than or equal to
connUnitEventFilter are logged in connUnitEventTable.
Persistent across boots.
Parsed from file FCMGMT-MIB-ipfc-07.txt
Company: None
Module: FCMGMT-MIB
This value defines the event severity
that will be logged by this connectivity unit.
All events of severity less than or equal to
connUnitEventFilter are logged in connUnitEventTable.
Persistent across boots.
connUnitEventFilter OBJECT-TYPE SYNTAX FcEventSeverity ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to connUnitEventFilter are logged in connUnitEventTable. Persistent across boots." ::= { connUnitEntry 25 }
connUnitEventFilter OBJECT-TYPE SYNTAX FcEventSeverity ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to connUnitEventFilter are logged in connUnitEventTable. Persistent across boots." ::= { connUnitEntry 25 }
Vendor: Brocade
Module: FCMGMT-MIB (FAFCMGMT.mib)
Type: TABULAR
Access: read-write
Syntax: FcEventSeverity
Automatically extracted from www.mibdepot.com
connUnitEventFilter OBJECT-TYPE SYNTAX FcEventSeverity ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to connUnitEventFilter are logged in connUnitEventTable. Persistent across boots." ::= { connUnitEntry 25 }
connUnitEventFilter OBJECT-TYPE SYNTAX FcEventSeverity ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to connUnitEventFilter are logged in connUnitEventTable. Persistent across boots." ::= { connUnitEntry 25 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.3.94.1.6.1.1 | connUnitId | 0 | 0 | The unique identification for this connectivity unit among those within this proxy domain. The value MUST be unique within the pr… |
1.3.6.1.3.94.1.6.1.2 | connUnitGlobalId | 0 | 0 | An optional global-scope identifier for this connectivity unit. It MUST be a WWN for this connectivity unit or 16 octets of value… |
1.3.6.1.3.94.1.6.1.3 | connUnitType | 0 | 0 | The type of this connectivity unit. |
1.3.6.1.3.94.1.6.1.4 | connUnitNumports | 0 | 0 | Number of physical ports in the connectivity unit (internal/embedded, external). |
1.3.6.1.3.94.1.6.1.5 | connUnitState | 0 | 0 | Overall state of the connectivity unit. |
1.3.6.1.3.94.1.6.1.6 | connUnitStatus | 0 | 0 | Overall status of the connectivity unit. The goal of this object is to be the single poll point to check the status of the connu… |
1.3.6.1.3.94.1.6.1.7 | connUnitProduct | 0 | 0 | The connectivity unit vendor's product model name. |
1.3.6.1.3.94.1.6.1.8 | connUnitSn | 0 | 0 | The serial number for this connectivity unit. |
1.3.6.1.3.94.1.6.1.9 | connUnitUpTime | 0 | 0 | The number of centiseconds since the last unit initialization. |
1.3.6.1.3.94.1.6.1.10 | connUnitUrl | 0 | 0 | URL to launch a management application, if applicable. Otherwise empty string. In a standalone unit, this would be the same as the… |
1.3.6.1.3.94.1.6.1.11 | connUnitDomainId | 0 | 0 | 24 bit Fibre Channel address ID of this connectivity unit, right justified with leading zero's if required. This should be set to… |
1.3.6.1.3.94.1.6.1.12 | connUnitProxyMaster | 0 | 0 | A value of 'yes' means this is the proxy master unit for a set of managed units. For example, this could be the only unit with a … |
1.3.6.1.3.94.1.6.1.13 | connUnitPrincipal | 0 | 0 | Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, return… |
1.3.6.1.3.94.1.6.1.14 | connUnitNumSensors | 0 | 0 | Number of sensors in the connUnitSensorTable. |
1.3.6.1.3.94.1.6.1.15 | connUnitStatusChangeTime | 0 | 0 | The sysuptime timestamp in centiseconds at which the last status change occurred. |
1.3.6.1.3.94.1.6.1.16 | connUnitConfigurationChangeTime | 0 | 0 | The sysuptime timestamp in centiseconds at which the last configuration change occurred. |
1.3.6.1.3.94.1.6.1.17 | connUnitNumRevs | 0 | 0 | The number of revisions in the connUnitRevsTable. |
1.3.6.1.3.94.1.6.1.18 | connUnitNumZones | 0 | 0 | Number of zones defined in connUnitZoneTable. |
1.3.6.1.3.94.1.6.1.19 | connUnitModuleId | 0 | 0 | This is a unique id, persistent between boots, that can be used to group a set of connUnits together into a module. The intended … |
1.3.6.1.3.94.1.6.1.20 | connUnitName | 0 | 0 | A display string containing a name for this connectivity unit. This object value should be persistent between boots. |
1.3.6.1.3.94.1.6.1.21 | connUnitInfo | 0 | 0 | A display string containing information about this connectivity unit. This object value should be persistent between boots. |
1.3.6.1.3.94.1.6.1.22 | connUnitControl | 0 | 0 | This object is used to control the addressed connUnit. NOTE: 'Cold Start' and 'Warm Start' are as defined in MIB II and are not m… |
1.3.6.1.3.94.1.6.1.23 | connUnitContact | 0 | 0 | Contact information for this connectivity unit. Persistent across boots. |
1.3.6.1.3.94.1.6.1.24 | connUnitLocation | 0 | 0 | Location information for this connectivity unit.Persistent across boots. |
1.3.6.1.3.94.1.6.1.26 | connUnitNumEvents | 0 | 0 | Number of events currently in the connUnitEventTable. |
1.3.6.1.3.94.1.6.1.27 | connUnitMaxEvents | 0 | 0 | Max number of events that can be defined in connUnitEventTable. |
1.3.6.1.3.94.1.6.1.28 | connUnitEventCurrID | 0 | 0 | The last used event id (connUnitEventIndex). |
1.3.6.1.3.94.1.6.1.29 | connUnitFabricID | 0 | 0 | A globally unique value to identify the fabric that this ConnUnit belongs to, otherwise empty string. This would typically be equ… |
1.3.6.1.3.94.1.6.1.30 | connUnitNumLinks | 0 | 0 | The number of links in the link table. |
1.3.6.1.3.94.1.6.1.31 | connUnitVendorId | 0 | 0 | The connectivity unit vendor's name. |