A currently unassigned value of hpicfLinkTestIndex.
The value 0 indicates that no unassigned values are
available.
In order to cause a non-zero value of this object to
be assigned for use as the hpicfLinkTestIndex of a
future link test, it must be successfully modified by
a set operation. When modified by a set operation,
the new value must precisely match the value
presently held by the object. If not, the management
protocol set operation will fail.
Immediately after the completion of a successful set
operation, the agent must modify the value of this
object. The algorithm for modifying the value is
implementation-dependent, and may use a subset of
values within the legal range. However, the agent
must guarantee that the new value is not assigned to
any in-use value of hpicfLinkTestIndex.
A management station creates a new link test using
this algorithm:
- issue a management protocol retrieval operation
to obtain the value of hpicfLinkTestNextIndex;
if the retrieved value is zero, a new link test
cannot be created at this time;
- issue a management protocol set operation for
hpicfLinkTestNextIndex, supplying the same value
as obtained in the previous step;
- if the set operation succeeds, use the supplied
value as the hpicfLinkTestIndex of the new
link test; if the set operation fails, go back
to the first step and obtain a new value for
hpicfLinkTestNextIndex;
- issue a management protocol set operation to
create an instance of the hpicfLinkTestStatus
object setting its value to 'createAndGo' or
'createAndWait' (as specified in the description
of the RowStatus textual convention).
Note that the set of hpicfLinkTestNextIndex and the
instance of hpicfLinkTestStatus may occur in the
same set operation if desired.
Parsed from file hpicfLinktest.mib.txt
Company: None
Module: HP-ICF-LINKTEST
A currently unassigned value of hpicfLinkTestIndex.
The value 0 indicates that no unassigned values are
available.
In order to cause a non-zero value of this object to
be assigned for use as the hpicfLinkTestIndex of a
future link test, it must be successfully modified by
a set operation. When modified by a set operation,
the new value must precisely match the value
presently held by the object. If not, the management
protocol set operation will fail.
Immediately after the completion of a successful set
operation, the agent must modify the value of this
object. The algorithm for modifying the value is
implementation-dependent, and may use a subset of
values within the legal range. However, the agent
must guarantee that the new value is not assigned to
any in-use value of hpicfLinkTestIndex.
A management station creates a new link test using
this algorithm:
- issue a management protocol retrieval operation
to obtain the value of hpicfLinkTestNextIndex;
if the retrieved value is zero, a new link test
cannot be created at this time;
- issue a management protocol set operation for
hpicfLinkTestNextIndex, supplying the same value
as obtained in the previous step;
- if the set operation succeeds, use the supplied
value as the hpicfLinkTestIndex of the new
link test; if the set operation fails, go back
to the first step and obtain a new value for
hpicfLinkTestNextIndex;
- issue a management protocol set operation to
create an instance of the hpicfLinkTestStatus
object setting its value to 'createAndGo' or
'createAndWait' (as specified in the description
of the RowStatus textual convention).
Note that the set of hpicfLinkTestNextIndex and the
instance of hpicfLinkTestStatus may occur in the
same set operation if desired.
Parsed from file HP-ICF-LINKTEST.mib
Module: HP-ICF-LINKTEST
Vendor: Hewlett-Packard
Module: HP-ICF-LINKTEST
[Automatically extracted from oidview.com]
hpicfLinkTestNextIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A currently unassigned value of hpicfLinkTestIndex. The value 0 indicates that no unassigned values are available. In order to cause a non-zero value of this object to be assigned for use as the hpicfLinkTestIndex of a future link test, it must be successfully modified by a set operation. When modified by a set operation, the new value must precisely match the value presently held by the object. If not, the management protocol set operation will fail. Immediately after the completion of a successful set operation, the agent must modify the value of this object. The algorithm for modifying the value is implementation-dependent, and may use a subset of values within the legal range. However, the agent must guarantee that the new value is not assigned to any in-use value of hpicfLinkTestIndex. A management station creates a new link test using this algorithm: - issue a management protocol retrieval operation to obtain the value of hpicfLinkTestNextIndex; if the retrieved value is zero, a new link test cannot be created at this time; - issue a management protocol set operation for hpicfLinkTestNextIndex, supplying the same value as obtained in the previous step; - if the set operation succeeds, use the supplied value as the hpicfLinkTestIndex of the new link test; if the set operation fails, go back to the first step and obtain a new value for hpicfLinkTestNextIndex; - issue a management protocol set operation to create an instance of the hpicfLinkTestStatus object setting its value to 'createAndGo' or 'createAndWait' (as specified in the description of the RowStatus textual convention). Note that the set of hpicfLinkTestNextIndex and the instance of hpicfLinkTestStatus may occur in the same set operation if desired." ::= { hpicfLinktest 1 }
hpicfLinkTestNextIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A currently unassigned value of hpicfLinkTestIndex. The value 0 indicates that no unassigned values are available. In order to cause a non-zero value of this object to be assigned for use as the hpicfLinkTestIndex of a future link test, it must be successfully modified by a set operation. When modified by a set operation, the new value must precisely match the value presently held by the object. If not, the management protocol set operation will fail. Immediately after the completion of a successful set operation, the agent must modify the value of this object. The algorithm for modifying the value is implementation-dependent, and may use a subset of values within the legal range. However, the agent must guarantee that the new value is not assigned to any in-use value of hpicfLinkTestIndex. A management station creates a new link test using this algorithm: - issue a management protocol retrieval operation to obtain the value of hpicfLinkTestNextIndex; if the retrieved value is zero, a new link test cannot be created at this time; - issue a management protocol set operation for hpicfLinkTestNextIndex, supplying the same value as obtained in the previous step; - if the set operation succeeds, use the supplied value as the hpicfLinkTestIndex of the new link test; if the set operation fails, go back to the first step and obtain a new value for hpicfLinkTestNextIndex; - issue a management protocol set operation to create an instance of the hpicfLinkTestStatus object setting its value to 'createAndGo' or 'createAndWait' (as specified in the description of the RowStatus textual convention). Note that the set of hpicfLinkTestNextIndex and the instance of hpicfLinkTestStatus may occur in the same set operation if desired." ::= { hpicfLinktest 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11.2.14.11.1.6.1.0 | hpicfLinkTestNextIndex | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.11.2.14.11.1.6.2 | hpicfLinkTestTable | 1 | 15 | A table of in-progress link tests. |