This object indicates whether this switch link is
enabled ('active') or disabled ('redundant') due to
one of the following:
- There are more links to this switch than there
are repeater segments.
- The agent detected a switching loop.
- The link is intended as a backup connection for
other links on this switch.
There can only be one active link to the switch from
each repeater segment, otherwise you will have a
switching loop. Therefore, if more than one switch
link is connected to repeater ports on the same
repeater segment, only one of them may have the value
'active'. All of the others must have the value
'redundant.
Parsed from file hpicfGenRptr.mib.txt
Company: None
Module: HP-ICF-GENERIC-RPTR
This object indicates whether this switch link is
enabled ('active') or disabled ('redundant') due to
one of the following:
- There are more links to this switch than there
are repeater segments.
- The agent detected a switching loop.
- The link is intended as a backup connection for
other links on this switch.
There can only be one active link to the switch from
each repeater segment, otherwise you will have a
switching loop. Therefore, if more than one switch
link is connected to repeater ports on the same
repeater segment, only one of them may have the value
'active'. All of the others must have the value
'redundant.
Parsed from file HP-ICF-GENERIC-RPTR.mib
Module: HP-ICF-GENERIC-RPTR
Vendor: Hewlett-Packard
Module: HP-ICF-GENERIC-RPTR
[Automatically extracted from oidview.com]
hpicfGRpSwitchLinkState OBJECT-TYPE SYNTAX INTEGER { active(1), redundant(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether this switch link is enabled ('active') or disabled ('redundant') due to one of the following: - There are more links to this switch than there are repeater segments. - The agent detected a switching loop. - The link is intended as a backup connection for other links on this switch. There can only be one active link to the switch from each repeater segment, otherwise you will have a switching loop. Therefore, if more than one switch link is connected to repeater ports on the same repeater segment, only one of them may have the value 'active'. All of the others must have the value 'redundant." ::= { hpicfGRpSwitchLinkEntry 4 }
hpicfGRpSwitchLinkState OBJECT-TYPE SYNTAX INTEGER { active(1), redundant(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether this switch link is enabled ('active') or disabled ('redundant') due to one of the following: - There are more links to this switch than there are repeater segments. - The agent detected a switching loop. - The link is intended as a backup connection for other links on this switch. There can only be one active link to the switch from each repeater segment, otherwise you will have a switching loop. Therefore, if more than one switch link is connected to repeater ports on the same repeater segment, only one of them may have the value 'active'. All of the others must have the value 'redundant." ::= { hpicfGRpSwitchLinkEntry 4 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.4.5.2.1.1 | hpicfGRpSwitchLinkIndex | 0 | 0 | An identifier that uniquely identifies this switch link among all of the links associated with this switch. The values of this o… |
| 1.3.6.1.4.1.11.2.14.11.4.5.2.1.2 | hpicfGRpSwitchLinkRptrGroup | 0 | 0 | The group containing the repeater port to which this switch link is attached. For internal switches, this object may not be modi… |
| 1.3.6.1.4.1.11.2.14.11.4.5.2.1.3 | hpicfGRpSwitchLinkRptrPort | 0 | 0 | The repeater port within the group to which this switch link is attached. For internal switches, this object may not be modified… |