Generated whenever a the hcxUpstreamUnitSecServState
changes in value. This an event with no clear
condition. Only severity is WARNING.
Parsed from file com21.hcxrx.mib.txt
Company: None
Module: COM21-HCXRX-MIB
Generated whenever a the hcxUpstreamUnitSecServState
changes in value. This an event with no clear
condition. Only severity is WARNING.
Parsed from file COM21-HCXRX-MIB.mib
Module: COM21-HCXRX-MIB
Vendor: Com21
Module: COM21-HCXRX-MIB
[Automatically extracted from oidview.com]
hcxUpstreamUnitSecStateChange NOTIFICATION-TYPE OBJECTS { hcxAlmSeverity, hcxEventLogTime, hcxUpstreamShelfId, hcxUpstreamSlotId, hcxUpstreamUnitSecServState } STATUS current DESCRIPTION " Generated whenever a the hcxUpstreamUnitSecServState changes in value. This an event with no clear condition. Only severity is WARNING." ::= { com21Traps 31 }
hcxUpstreamUnitSecStateChange NOTIFICATION-TYPE OBJECTS { hcxAlmSeverity, hcxEventLogTime, hcxUpstreamShelfId, hcxUpstreamSlotId, hcxUpstreamUnitSecServState } STATUS current DESCRIPTION " Generated whenever a the hcxUpstreamUnitSecServState changes in value. This an event with no clear condition. Only severity is WARNING." ::= { com21Traps 31 }
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.1141.4.10 | hcxControlPrimServStateChange | 0 | 0 | generated whenever hcxControlPrimaryServiceState changes value. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.11 | hcxControlSecServStateChange | 0 | 0 | generated whenever hcxControlSecondaryServiceState changes value. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.12 | hcxCcDiagTestComplete | 0 | 0 | This notification is generated whenever the CC card internal diagnostic tests are completed. Event only, no clear. Only severity … |
1.3.6.1.4.1.1141.4.13 | hcxCcTestStatusLedChange | 0 | 0 | generated whenever there is a change in test LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.14 | hcxCcFaultStatusLedChange | 0 | 0 | generated whenever there is a change in the Fault LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.15 | hcxCcEtherLinkStatusLedChange | 0 | 0 | generated whenever there is a change in link LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.16 | hcxCcFlashBackupComplete | 0 | 0 | This notification is generated whenever the CC card completes a user directed flash backup of configuration. Only severity allowe… |
1.3.6.1.4.1.1141.4.17 | hcxDiskAccessFailure | 0 | 0 | generated whenever there is a failure to access the PCMCIA disk. Default severity is MAJOR. |
1.3.6.1.4.1.1141.4.18 | hcxDiskAccessFailClear | 0 | 0 | generated whenever a previously reported disk failure is cleared. Severity is CLEARED. |
1.3.6.1.4.1.1141.4.19 | hcxDbActionComplete | 0 | 0 | this notification is generated whenever the CC completes the database action. This an event with no clear condition. Only severit… |
1.3.6.1.4.1.1141.4.20 | hcxEtherUnitPrimStateChange | 0 | 0 | This trap is generated whenever a change in the the hcxEtherUnitPrimServState occurs. This an event with no clear condition. Only… |
1.3.6.1.4.1.1141.4.21 | hcxEtherUnitSecStateChange | 0 | 0 | This trap is generated whenever a change in the the hcxEtherUnitSecServState occurs. This an event with no clear condition. Only … |
1.3.6.1.4.1.1141.4.22 | hcxEtherTestStatusLedChange | 0 | 0 | generated whenever there is a change in test LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.23 | hcxEtherFaultStatusLedChange | 0 | 0 | generated whenever there is a change in the Fault LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.24 | hcxEtherPortPrimStateChange | 0 | 0 | This trap is generated whenever a change in the the hcxEtherPortPrimServState occurs. This an event with no clear condition. Only… |
1.3.6.1.4.1.1141.4.25 | hcxEtherPortSecStateChange | 0 | 0 | This trap is generated whenever a change in the the hcxEtherPortSecServState occurs. This an event with no clear condition. Only … |
1.3.6.1.4.1.1141.4.26 | hcxEtherPortDiagTestComplete | 0 | 0 | This notification is generated whenever the Ethernet port internal diagnostic tests are completed. Event only, no clear. Only sev… |
1.3.6.1.4.1.1141.4.27 | hcxEtherOperationFailure | 0 | 0 | This notification is generated by the CC whenever an Ethernet port fails to respond correctly to a request. This failure could in… |
1.3.6.1.4.1.1141.4.28 | hcxEtherPortLinkStatusLedChange | 0 | 0 | generated whenever there is a change in link LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.30 | hcxUpstreamUnitPrimStateChange | 0 | 0 | Generated whenever a the hcxUpstreamUnitPrimServState changes in value. This an event with no clear condition. Only severity is W… |
1.3.6.1.4.1.1141.4.32 | hcxUpDiagTestComplete | 0 | 0 | This notification is generated whenever the RX internal diagnostic tests are completed. This an event with no clear condition. On… |
1.3.6.1.4.1.1141.4.33 | hcxUpTestStatusLedChange | 0 | 0 | generated whenever there is a change in test LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.34 | hcxUpFaultStatusLedChange | 0 | 0 | generated whenever there is a change in the Fault LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.35 | hcxUpOperationFailure | 0 | 0 | This notification is generated by the CC whenever an RX card fails to respond correctly to a request. This failure could indicate… |
1.3.6.1.4.1.1141.4.37 | hcxUncorFecHecMinThres | 0 | 0 | Severity is WARNING. |
1.3.6.1.4.1.1141.4.38 | hcxCorrectedFecMinThres | 0 | 0 | Severity is WARNING. |
1.3.6.1.4.1.1141.4.40 | hcxMajorStatusLedChange | 0 | 0 | generated whenever there is a change in major alarm LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.41 | hcxMinorStatusLedChange | 0 | 0 | generated whenever there is a change in minor alarm LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.42 | hcxHcxSwDnldComplete | 0 | 0 | This notification is generated whenever the CC completes the ComController software image download. This an event with no clear c… |
1.3.6.1.4.1.1141.4.44 | hcxCnfgBackupComplete | 0 | 0 | This notification is generated whenever the CC completes the configuration data backup. This an event with no clear condition. On… |
1.3.6.1.4.1.1141.4.45 | hcxBootpFailed | 0 | 0 | This notification is generated whenever the CC fails to successfully complete a bootp operation. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.46 | hcxPowerFailDetected | 0 | 0 | This notification is generated whenever a power failure condition is detected. Default severity is MAJOR. |
1.3.6.1.4.1.1141.4.47 | hcxPowerFailClear | 0 | 0 | This notification is generated whenever a power failure condition is removed. Severity is CLEARED. |
1.3.6.1.4.1.1141.4.48 | hcxFanFailDetected | 0 | 0 | This notification is generated whenever a fan failure condition is detected. Default severity is MAJOR. |
1.3.6.1.4.1.1141.4.49 | hcxFanFailClear | 0 | 0 | This notification is generated whenever a fan failure condition is removed. Severity is CLEARED. |
1.3.6.1.4.1.1141.4.50 | stuTopologyChange | 0 | 0 | This trap is sent at a maximum rate of once every 5seconds or when 100 ComPort acquisition/deacquisitions have occured, which eve… |
1.3.6.1.4.1.1141.4.51 | hcxStuResourceExhausted | 0 | 0 | generated whenever an ComPort must be denied acquisition due to a lack of CC resources. This includes an exhaustion of SIDs, leck… |
1.3.6.1.4.1.1141.4.52 | hcxInsertChange | 0 | 0 | generated whenever a card is inserted for the first time, or during restart of the ComController. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.53 | hcxMismatchDetect | 0 | 0 | generated when the inserted card does not match the configured card type. Default severity is MAJOR. |
1.3.6.1.4.1.1141.4.54 | hcxMismatchClear | 0 | 0 | this mismatch clear is submitted when an incorrect card is removed from a slot. Severity is CLEARED. |
1.3.6.1.4.1.1141.4.55 | hcxCardNoRespond | 0 | 0 | generated when an inserted card fails to respond to a CC generated message. This an event with no clear condition. Only severity … |
1.3.6.1.4.1.1141.4.56 | hcxCardPollFail | 0 | 0 | generated when an inserted card fails to respond to a CC polling. Default severity is MAJOR. |
1.3.6.1.4.1.1141.4.57 | hcxCardPollFailClear | 0 | 0 | generated when a card successfully responses to CC polling after a previous failure. Only severity is CLEARED. |
1.3.6.1.4.1.1141.4.58 | hcxCardDnldFailNoImage | 0 | 0 | generated when a card cannot be download due to a lack of the correct image. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.59 | hcxRestartNotify | 0 | 0 | this trap is generated upon HCX initialization after a restart. This trap indicates to a management system that the HCX SNMP Agen… |
1.3.6.1.4.1.1141.4.60 | hcxDnstrmUnitPrimStateChange | 0 | 0 | Generated whenever a the hcxDnstreamUnitPrimServState changes in value. This an event with no clear condition. Only severity is W… |
1.3.6.1.4.1.1141.4.61 | hcxDnstrmUnitSecStateChange | 0 | 0 | Generated whenever a the hcxDnstreamUnitSecServState changes in value. This an event with no clear condition. Only severity is WA… |
1.3.6.1.4.1.1141.4.62 | hcxDnDiagTestComplete | 0 | 0 | This notification is generated whenever the TX internal diagnostic tests are completed. This an event with no clear condition. On… |
1.3.6.1.4.1.1141.4.63 | hcxDnTestStatusLedChange | 0 | 0 | generated whenever there is a change in test LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.64 | hcxDnFaultStatusLedChange | 0 | 0 | generated whenever there is a change in the Fault LED status. This an event with no clear condition. Only severity is WARNING. |
1.3.6.1.4.1.1141.4.65 | hcxDnOperationFailure | 0 | 0 | This notification is generated by the CC whenever a TX card fails to respond correctly to a request. This failure could indicate … |
1.3.6.1.4.1.1141.4.68 | hcxSynthLockLossDetected | 0 | 0 | Default severity is MINOR. |
1.3.6.1.4.1.1141.4.69 | hcxSynthLockLossClear | 0 | 0 | Severity is CLEARED. |
1.3.6.1.4.1.1141.4.70 | hcxLossOfFrameClkDetected | 0 | 0 | Default severity is MINOR. |
1.3.6.1.4.1.1141.4.71 | hcxLossOfFrameClkClear | 0 | 0 | Severity is CLEARED. |
1.3.6.1.4.1.1141.4.80 | hcxCorrFecRatioThres | 0 | 0 | Severity is WARNING. |
1.3.6.1.4.1.1141.4.81 | hcxCellErrRatioThres | 0 | 0 | Severity is WARNING. |
... |