Reference record for OID 1.3.6.1.4.1.119.2.3.14.9.4.5



parent
1.3.6.1.4.1.119.2.3.14.9.4 (conn)
node code
5
node name
connSoftPvcTable
dot oid
1.3.6.1.4.1.119.2.3.14.9.4.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nec(119) nec-mib(2) necProductDepend(3) atomis-mib(14) m7-phase2-mib(9) conn(4) connSoftPvcTable(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nec(119) nec-mib(2) necProductDepend(3) atomis-mib(14) m7-phase2-mib(9) conn(4) connSoftPvcTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nec(119) nec-mib(2) necProductDepend(3) atomis-mib(14) m7-phase2-mib(9) conn(4) connSoftPvcTable(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nec(119) nec-mib(2) necProductDepend(3) atomis-mib(14) m7-phase2-mib(9) conn(4) connSoftPvcTable(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nec(119) nec-mib(2) necProductDepend(3) atomis-mib(14) m7-phase2-mib(9) conn(4) connSoftPvcTable(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nec(119) nec-mib(2) necProductDepend(3) atomis-mib(14) m7-phase2-mib(9) conn(4) connSoftPvcTable(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nec/nec-mib/necProductDepend/atomis-mib/m7-phase2-mib/conn/connSoftPvcTable
  • /iso/identified-organization/dod/internet/private/enterprises/nec/nec-mib/necProductDepend/atomis-mib/m7-phase2-mib/conn/connSoftPvcTable
  • /iso/org/dod/internet/private/enterprise/nec/nec-mib/necProductDepend/atomis-mib/m7-phase2-mib/conn/connSoftPvcTable
  • /iso/org/dod/internet/private/enterprises/nec/nec-mib/necProductDepend/atomis-mib/m7-phase2-mib/conn/connSoftPvcTable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/nec/nec-mib/necProductDepend/atomis-mib/m7-phase2-mib/conn/connSoftPvcTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nec/nec-mib/necProductDepend/atomis-mib/m7-phase2-mib/conn/connSoftPvcTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/119/2/3/14/9/4/5

    Description by oid_info

    connSoftpvcTable
    View at oid-info.com

    Description by mibdepot

    This table include all entries to Soft-PVPC/PVCC
    currently available between the lines or the line and
    CPU port of the switch. Also, this table is used to
    set or delete Soft-PVPC/PVCC. The operable
    connection form between Soft-PVPC/PVCC is bi-
    directional point-to-point only.

    The procedure to set the connection is as follows:

    1. Acquire connSoftPvcIndex
    To set the connection, read connSoftPvcIndexNext and
    obtain an index of the Soft-PVPC/PVCC table. The
    index must be managed by NMS. (The index is required
    to take an action to the connection.)

    2. Set createAndWait
    Set connSoftPvcRowStatus to CreateAndWait, using the
    obtained connSoftPvcIndex as index. If the agent
    will set the parameter for the Soft-PVPC/PVCC
    setting to the default value and make
    connSoftRowStatus to notReady.

    However, the same manager cannot create another row
    while creating a row (the status of the row is notRedy
    or notInService).

    3. Get the default value
    Get the default value of the object which serves as
    parameter for the connection setting. (The agent
    shall return -1 if it does not have a default value.)

    Default values are as follows:

    connSoftPvcTopology bi-directional-VCC(2)
    connSoftPvcTrafficType traffic-UBR(5)
    connSoftPvcEndpointType calling(1)
    connSoftPvcRetry 2
    connSoftPvcSrcAtmAddressFormat nsap(2)
    connSoftPvcSrcAtmAddressLength None
    connSoftPvcSrcAtmAddress 0 length string
    connSoftPvcSrcIfIndex None
    connSoftPvcSrcVPI None
    connSoftPvcSrcVCI None
    connSoftPvcDstAtmAddressFormat nsap(2)
    connSoftPvcDstAtmAddressLength None
    connSoftPvcDstAtmAddress 0 length string
    connSoftPvcDstIfIndex None
    connSoftPvcDstVPI None
    connSoftPvcDstVCI None
    connSoftPvcSrcFifoIndex 0
    connSoftPvcDstFifoIndex 0
    connSoftPvcNodeKind model5(1)
    connSoftPvcSrcParam1 off(1)
    connSoftPvcDstParam1 off(1)
    connSoftPvcSrcParam2 0 length string
    connSoftPvcDstParam2 0 length string
    connSoftPvcSrcParam3 -1
    connSoftPvcDstParam3 -1
    connSoftPvcSrcParam4 -1
    connSoftPvcDstParam4 -1
    connSoftPvcSrcParam5 -1
    connSoftPvcDstParam5 -1
    connSoftPvcSrcParam6 off(2)
    connSoftPvcDstParam6 off(2)
    connSoftPvcSrcParam7 None (not installed)
    connSoftPvcDstParam7 None (not installed)

    4. Set parameter
    If a parameter does not have a default value, or the
    default value should not be used, set the parameter to
    a value.
    If all parameters are set, the agent shall make
    connSoftPvcRowStatus to notInService.

    5. Set active
    By doing so, the agent checks parameters, resources and
    establishes the connection.

    6. Get connSoftPvcRowStatus
    If connSoftPvcRowStatus is active, the connection
    setting completed successfully, if notInService,the
    connection setting failed. For the cause, refer to
    connSoftPvcCause.
    (Note) When the connection setting has failed, if the
    connection is not released, the row will remain.

    7. Get connSoftPvcRestRetry
    Remaining counts of retry are contained. If it is
    positive value, the retry is in progress. If
    connSoftPvcRestRetry is 0, the retry completed. The
    result of the connection setting should be seen, when
    this object is 0.
    -1 means that infinite retry is in progress.

    ***Special pattern***
    (1) If connSoftPvcTopology is bi-directional-VPC, set
    connSoftPvcSrcVCI, connSoftPvcDstVCI to 0.

    The procedure to release the connection is as follows:

    1. Set 'destroy'
    Set connSoftPvcRowStatus to 'destroy', using
    connSoftPvcIndex of the connection to be deleted as
    index.
    The agent will delete the connection, referring to
    it.
    (Note) 'destroy' can also be set during the bypass
    processing.

    2. Get the result
    If the connection is deleted, 'get' of
    connSoftPvcTable of the designated index becomes
    NoSuchName.

    The bypass processing of connection

    1. Set notInService
    When the agent executes the bypass processing of
    connection, set connSoftPvcRowStatus to
    notInService, and then establish the connection.

    2. Get connSoftPvcRowStatus
    If connSoftPvcRowStatus is 'active', the bypass
    connection setting has completed successfully.
    If connSoftPvcRowStatus remains 'notInService',
    the connection setting has failed.

    Others

    1. The cut and recovery processing of connection is
    performed, following the delete and set procedures
    of the concerned connection.
    Each procedure is as stated before.

    Parsed from file NEC-MIB.txt
    Company: None
    Module: NEC-MIB

    Description by circitor

    This table include all entries to Soft-PVPC/PVCC
    currently available between the lines or the line and
    CPU port of the switch. Also, this table is used to
    set or delete Soft-PVPC/PVCC. The operable
    connection form between Soft-PVPC/PVCC is bi-
    directional point-to-point only.

    The procedure to set the connection is as follows:

    1. Acquire connSoftPvcIndex
    To set the connection, read connSoftPvcIndexNext and
    obtain an index of the Soft-PVPC/PVCC table. The
    index must be managed by NMS. (The index is required
    to take an action to the connection.)

    2. Set createAndWait
    Set connSoftPvcRowStatus to CreateAndWait, using the
    obtained connSoftPvcIndex as index. If the agent
    will set the parameter for the Soft-PVPC/PVCC
    setting to the default value and make
    connSoftRowStatus to notReady.

    However, the same manager cannot create another row
    while creating a row (the status of the row is notRedy
    or notInService).

    3. Get the default value
    Get the default value of the object which serves as
    parameter for the connection setting. (The agent
    shall return -1 if it does not have a default value.)

    Default values are as follows:

    connSoftPvcTopology bi-directional-VCC(2)
    connSoftPvcTrafficType traffic-UBR(5)
    connSoftPvcEndpointType calling(1)
    connSoftPvcRetry 2
    connSoftPvcSrcAtmAddressFormat nsap(2)
    connSoftPvcSrcAtmAddressLength None
    connSoftPvcSrcAtmAddress 0 length string
    connSoftPvcSrcIfIndex None
    connSoftPvcSrcVPI None
    connSoftPvcSrcVCI None
    connSoftPvcDstAtmAddressFormat nsap(2)
    connSoftPvcDstAtmAddressLength None
    connSoftPvcDstAtmAddress 0 length string
    connSoftPvcDstIfIndex None
    connSoftPvcDstVPI None
    connSoftPvcDstVCI None
    connSoftPvcSrcFifoIndex 0
    connSoftPvcDstFifoIndex 0
    connSoftPvcNodeKind model5(1)
    connSoftPvcSrcParam1 off(1)
    connSoftPvcDstParam1 off(1)
    connSoftPvcSrcParam2 0 length string
    connSoftPvcDstParam2 0 length string
    connSoftPvcSrcParam3 -1
    connSoftPvcDstParam3 -1
    connSoftPvcSrcParam4 -1
    connSoftPvcDstParam4 -1
    connSoftPvcSrcParam5 -1
    connSoftPvcDstParam5 -1
    connSoftPvcSrcParam6 off(2)
    connSoftPvcDstParam6 off(2)
    connSoftPvcSrcParam7 None (not installed)
    connSoftPvcDstParam7 None (not installed)

    4. Set parameter
    If a parameter does not have a default value, or the
    default value should not be used, set the parameter to
    a value.
    If all parameters are set, the agent shall make
    connSoftPvcRowStatus to notInService.

    5. Set active
    By doing so, the agent checks parameters, resources and
    establishes the connection.

    6. Get connSoftPvcRowStatus
    If connSoftPvcRowStatus is active, the connection
    setting completed successfully, if notInService,the
    connection setting failed. For the cause, refer to
    connSoftPvcCause.
    (Note) When the connection setting has failed, if the
    connection is not released, the row will remain.

    7. Get connSoftPvcRestRetry
    Remaining counts of retry are contained. If it is
    positive value, the retry is in progress. If
    connSoftPvcRestRetry is 0, the retry completed. The
    result of the connection setting should be seen, when
    this object is 0.
    -1 means that infinite retry is in progress.

    ***Special pattern***
    (1) If connSoftPvcTopology is bi-directional-VPC, set
    connSoftPvcSrcVCI, connSoftPvcDstVCI to 0.

    The procedure to release the connection is as follows:

    1. Set 'destroy'
    Set connSoftPvcRowStatus to 'destroy', using
    connSoftPvcIndex of the connection to be deleted as
    index.
    The agent will delete the connection, referring to
    it.
    (Note) 'destroy' can also be set during the bypass
    processing.

    2. Get the result
    If the connection is deleted, 'get' of
    connSoftPvcTable of the designated index becomes
    NoSuchName.

    The bypass processing of connection

    1. Set notInService
    When the agent executes the bypass processing of
    connection, set connSoftPvcRowStatus to
    notInService, and then establish the connection.

    2. Get connSoftPvcRowStatus
    If connSoftPvcRowStatus is 'active', the bypass
    connection setting has completed successfully.
    If connSoftPvcRowStatus remains 'notInService',
    the connection setting has failed.

    Others

    1. The cut and recovery processing of connection is
    performed, following the delete and set procedures
    of the concerned connection.
    Each procedure is as stated before.

    Parsed from file NEC-MIB.mib
    Module: NEC-MIB

    Information by oid_info

    Vendor: NEC
    Module: NEC-MIB (NEC-MIB)
    Type: TABLE
    Access: not-accessible
    Syntax: SEQUENCE OF

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    connSoftPvcTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnSoftPvcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table include all entries to Soft-PVPC/PVCC currently available between the lines or the line and CPU port of the switch. Also, this table is used to set or delete Soft-PVPC/PVCC. The operable connection form between Soft-PVPC/PVCC is bi- directional point-to-point only. The procedure to set the connection is as follows: 1. Acquire connSoftPvcIndex To set the connection, read connSoftPvcIndexNext and obtain an index of the Soft-PVPC/PVCC table. The index must be managed by NMS. (The index is required to take an action to the connection.) 2. Set createAndWait Set connSoftPvcRowStatus to CreateAndWait, using the obtained connSoftPvcIndex as index. If the agent will set the parameter for the Soft-PVPC/PVCC setting to the default value and make connSoftRowStatus to notReady. However, the same manager cannot create another row while creating a row (the status of the row is notRedy or notInService). 3. Get the default value Get the default value of the object which serves as parameter for the connection setting. (The agent shall return -1 if it does not have a default value.) Default values are as follows: connSoftPvcTopology bi-directional-VCC(2) connSoftPvcTrafficType traffic-UBR(5) connSoftPvcEndpointType calling(1) connSoftPvcRetry 2 connSoftPvcSrcAtmAddressFormat nsap(2) connSoftPvcSrcAtmAddressLength None connSoftPvcSrcAtmAddress 0 length string connSoftPvcSrcIfIndex None connSoftPvcSrcVPI None connSoftPvcSrcVCI None connSoftPvcDstAtmAddressFormat nsap(2) connSoftPvcDstAtmAddressLength None connSoftPvcDstAtmAddress 0 length string connSoftPvcDstIfIndex None connSoftPvcDstVPI None connSoftPvcDstVCI None connSoftPvcSrcFifoIndex 0 connSoftPvcDstFifoIndex 0 connSoftPvcNodeKind model5(1) connSoftPvcSrcParam1 off(1) connSoftPvcDstParam1 off(1) connSoftPvcSrcParam2 0 length string connSoftPvcDstParam2 0 length string connSoftPvcSrcParam3 -1 connSoftPvcDstParam3 -1 connSoftPvcSrcParam4 -1 connSoftPvcDstParam4 -1 connSoftPvcSrcParam5 -1 connSoftPvcDstParam5 -1 connSoftPvcSrcParam6 off(2) connSoftPvcDstParam6 off(2) connSoftPvcSrcParam7 None (not installed) connSoftPvcDstParam7 None (not installed) 4. Set parameter If a parameter does not have a default value, or the default value should not be used, set the parameter to a value. If all parameters are set, the agent shall make connSoftPvcRowStatus to notInService. 5. Set active By doing so, the agent checks parameters, resources and establishes the connection. 6. Get connSoftPvcRowStatus If connSoftPvcRowStatus is active, the connection setting completed successfully, if notInService,the connection setting failed. For the cause, refer to connSoftPvcCause. (Note) When the connection setting has failed, if the connection is not released, the row will remain. 7. Get connSoftPvcRestRetry Remaining counts of retry are contained. If it is positive value, the retry is in progress. If connSoftPvcRestRetry is 0, the retry completed. The result of the connection setting should be seen, when this object is 0. -1 means that infinite retry is in progress. ***Special pattern*** (1) If connSoftPvcTopology is bi-directional-VPC, set connSoftPvcSrcVCI, connSoftPvcDstVCI to 0. The procedure to release the connection is as follows: 1. Set 'destroy' Set connSoftPvcRowStatus to 'destroy', using connSoftPvcIndex of the connection to be deleted as index. The agent will delete the connection, referring to it. (Note) 'destroy' can also be set during the bypass processing. 2. Get the result If the connection is deleted, 'get' of connSoftPvcTable of the designated index becomes NoSuchName. The bypass processing of connection 1. Set notInService When the agent executes the bypass processing of connection, set connSoftPvcRowStatus to notInService, and then establish the connection. 2. Get connSoftPvcRowStatus If connSoftPvcRowStatus is 'active', the bypass connection setting has completed successfully. If connSoftPvcRowStatus remains 'notInService', the connection setting has failed. Others 1. The cut and recovery processing of connection is performed, following the delete and set procedures of the concerned connection. Each procedure is as stated before." ::= { conn 5 }

    Information by circitor

    connSoftPvcTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnSoftPvcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " This table include all entries to Soft-PVPC/PVCC currently available between the lines or the line and CPU port of the switch. Also, this table is used to set or delete Soft-PVPC/PVCC. The operable connection form between Soft-PVPC/PVCC is bi- directional point-to-point only. The procedure to set the connection is as follows: 1. Acquire connSoftPvcIndex To set the connection, read connSoftPvcIndexNext and obtain an index of the Soft-PVPC/PVCC table. The index must be managed by NMS. (The index is required to take an action to the connection.) 2. Set createAndWait Set connSoftPvcRowStatus to CreateAndWait, using the obtained connSoftPvcIndex as index. If the agent will set the parameter for the Soft-PVPC/PVCC setting to the default value and make connSoftRowStatus to notReady. However, the same manager cannot create another row while creating a row (the status of the row is notRedy or notInService). 3. Get the default value Get the default value of the object which serves as parameter for the connection setting. (The agent shall return -1 if it does not have a default value.) Default values are as follows: connSoftPvcTopology bi-directional-VCC(2) connSoftPvcTrafficType traffic-UBR(5) connSoftPvcEndpointType calling(1) connSoftPvcRetry 2 connSoftPvcSrcAtmAddressFormat nsap(2) connSoftPvcSrcAtmAddressLength None connSoftPvcSrcAtmAddress 0 length string connSoftPvcSrcIfIndex None connSoftPvcSrcVPI None connSoftPvcSrcVCI None connSoftPvcDstAtmAddressFormat nsap(2) connSoftPvcDstAtmAddressLength None connSoftPvcDstAtmAddress 0 length string connSoftPvcDstIfIndex None connSoftPvcDstVPI None connSoftPvcDstVCI None connSoftPvcSrcFifoIndex 0 connSoftPvcDstFifoIndex 0 connSoftPvcNodeKind model5(1) connSoftPvcSrcParam1 off(1) connSoftPvcDstParam1 off(1) connSoftPvcSrcParam2 0 length string connSoftPvcDstParam2 0 length string connSoftPvcSrcParam3 -1 connSoftPvcDstParam3 -1 connSoftPvcSrcParam4 -1 connSoftPvcDstParam4 -1 connSoftPvcSrcParam5 -1 connSoftPvcDstParam5 -1 connSoftPvcSrcParam6 off(2) connSoftPvcDstParam6 off(2) connSoftPvcSrcParam7 None (not installed) connSoftPvcDstParam7 None (not installed) 4. Set parameter If a parameter does not have a default value, or the default value should not be used, set the parameter to a value. If all parameters are set, the agent shall make connSoftPvcRowStatus to notInService. 5. Set active By doing so, the agent checks parameters, resources and establishes the connection. 6. Get connSoftPvcRowStatus If connSoftPvcRowStatus is active, the connection setting completed successfully, if notInService,the connection setting failed. For the cause, refer to connSoftPvcCause. (Note) When the connection setting has failed, if the connection is not released, the row will remain. 7. Get connSoftPvcRestRetry Remaining counts of retry are contained. If it is positive value, the retry is in progress. If connSoftPvcRestRetry is 0, the retry completed. The result of the connection setting should be seen, when this object is 0. -1 means that infinite retry is in progress. ***Special pattern*** (1) If connSoftPvcTopology is bi-directional-VPC, set connSoftPvcSrcVCI, connSoftPvcDstVCI to 0. The procedure to release the connection is as follows: 1. Set 'destroy' Set connSoftPvcRowStatus to 'destroy', using connSoftPvcIndex of the connection to be deleted as index. The agent will delete the connection, referring to it. (Note) 'destroy' can also be set during the bypass processing. 2. Get the result If the connection is deleted, 'get' of connSoftPvcTable of the designated index becomes NoSuchName. The bypass processing of connection 1. Set notInService When the agent executes the bypass processing of connection, set connSoftPvcRowStatus to notInService, and then establish the connection. 2. Get connSoftPvcRowStatus If connSoftPvcRowStatus is 'active', the bypass connection setting has completed successfully. If connSoftPvcRowStatus remains 'notInService', the connection setting has failed. Others 1. The cut and recovery processing of connection is performed, following the delete and set procedures of the concerned connection. Each procedure is as stated before." ::= { conn 5 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.119)

    Akiyama Yoshiyuki

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.119.2.3.14.9.4.5.1 connSoftPvcEntry 37 37 connSoftpvcEntry

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.119.2.3.14.9.4.1 connPvc 3 71 None
    1.3.6.1.4.1.119.2.3.14.9.4.2 connConf 2 20 None
    1.3.6.1.4.1.119.2.3.14.9.4.3 connRoute 2 61 None
    1.3.6.1.4.1.119.2.3.14.9.4.4 connSoftPvcIndexNext 1 1 connSoftpvcIndexNext
    1.3.6.1.4.1.119.2.3.14.9.4.6 connSoftPvcEstablishedSrcInfTable 1 3 connSoftpvcEstablishedSrcInftable
    1.3.6.1.4.1.119.2.3.14.9.4.7 connOam 2 38 None
    1.3.6.1.4.1.119.2.3.14.9.4.8 connLoop 1 29 None
    1.3.6.1.4.1.119.2.3.14.9.4.9 connProfile 4 17 None
    1.3.6.1.4.1.119.2.3.14.9.4.10 connSvcTable 1 3 JpnToEng[ËÜÁõÃÖ¤ËÀßÄꤵ¤ì¤ë SVC ¾ðÊó¤Î¥Æ¡¼¥Ö¥ë.]
    1.3.6.1.4.1.119.2.3.14.9.4.11 connCe 1 20 None
    1.3.6.1.4.1.119.2.3.14.9.4.12 connFr 2 32 None