In the multiple mode, the sorter can simultaneously be used by different computers. Each computer may assign its own output trays. This value determines how the tray is selected.
The value (-1) means others or 'not supported'.
Parsed from file kyocera.mib.txt
Company: None
Module: KYOCERA_Private_MIB
In the multiple mode, the sorter can simultaneously be used by different computers. Each computer may assign its own output trays. This value determines how the tray is selected.
The value (-1) means others or 'not supported'.
Parsed from file KYOCERA-Private-MIB.mib
Module: KYOCERA-Private-MIB
Vendor: Kyocera
Module: KYOCERA_Private_MIB (kyocera.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
kcprtOutputMultiMode OBJECT-TYPE SYNTAX INTEGER { off(0), id_specific(1), if_specific(2) } ACCESS read-write STATUS mandatory DESCRIPTION "In the multiple mode, the sorter can simultaneously be used by different computers. Each computer may assign its own output trays. This value determines how the tray is selected. The value (-1) means others or 'not supported'." ::={ kcprtOutputEntry 3 }
kcprtOutputMultiMode OBJECT-TYPE SYNTAX INTEGER { off(0), id-specific(1), if-specific(2) } ACCESS read-write STATUS mandatory DESCRIPTION "In the multiple mode, the sorter can simultaneously be used by different computers. Each computer may assign its own output trays. This value determines how the tray is selected. The value (-1) means others or 'not supported'." ::={ kcprtOutputEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1347.43.9.1.1.1 | kcprtOutputIndex | 0 | 0 | The value of the prtOutputIndex of this printer that this entry is associated with. |
1.3.6.1.4.1.1347.43.9.1.1.2 | kcprtOutputMode | 0 | 0 | The operation mode of the sorter. If this device does not support the sorter function, the reading value is (-1) and all writi… |
1.3.6.1.4.1.1347.43.9.1.1.4 | kcprtOutputGroupNumber | 0 | 0 | This entry shows how many groups are existing on the output device. |
1.3.6.1.4.1.1347.43.9.1.1.5 | kcprtOutputDefaultGroup | 0 | 0 | The value of the kcprtTrayGroupIndex corresponding to the current output tray group in a sorter. This value has no meaning if t… |
1.3.6.1.4.1.1347.43.9.1.1.6 | kcprtOutputBulkStatus | 0 | 0 | This entry shows current status of the bulk tray. Since the bulk tray of SO-6 has only a full sensor, this entry has only two s… |
1.3.6.1.4.1.1347.43.9.1.1.7 | kcprtOutputTrayMaxCapacity | 0 | 0 | This entry shows how many pages the tray on this output device can hold. Unit is sheet. |