dataLogMaxOutletCurrent OBJECT-TYPE
SYNTAX MilliAmps
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum value for the measurement period:
A unique value for the current sensor
attached to the outlet. This value is
reported in milliamps (1/1000th of an amp)"
View at oid-info.com
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.13742.4.1.10.1.1.1 | dataLogOutletIndex | 0 | 0 | dataLogOutletIndex OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value fo… |
1.3.6.1.4.1.13742.4.1.10.1.1.2 | dataLogOutletCurrent | 0 | 0 | dataLogOutletCurrent OBJECT-TYPE SYNTAX MilliAmps MAX-ACCESS read-only STATUS deprecated DESCRIPTION "A unique value for the cu… |
1.3.6.1.4.1.13742.4.1.10.1.1.3 | dataLogOutletVoltage | 0 | 0 | dataLogOutletVoltage OBJECT-TYPE SYNTAX MilliVolts MAX-ACCESS read-only STATUS deprecated DESCRIPTION "A unique value for the v… |
1.3.6.1.4.1.13742.4.1.10.1.1.4 | dataLogOutletPowerFactor | 0 | 0 | dataLogOutletPowerFactor OBJECT-TYPE SYNTAX PowerFactorPercentage MAX-ACCESS read-only STATUS deprecated DESCRIPTION "A unique … |
1.3.6.1.4.1.13742.4.1.10.1.1.5 | dataLogOutletOnTime | 0 | 0 | dataLogOutletOnTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time since thi… |
1.3.6.1.4.1.13742.4.1.10.1.1.6 | dataLogOutletWattHours | 0 | 0 | dataLogOutletWattHours OBJECT-TYPE SYNTAX WattHours MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The cumulative Active E… |
1.3.6.1.4.1.13742.4.1.10.1.1.7 | dataLogAvgOutletCurrent | 0 | 0 | dataLogAvgOutletCurrent OBJECT-TYPE SYNTAX MilliAmps MAX-ACCESS read-only STATUS current DESCRIPTION "The Average value for the… |
1.3.6.1.4.1.13742.4.1.10.1.1.9 | dataLogMinOutletCurrent | 0 | 0 | dataLogMinOutletCurrent OBJECT-TYPE SYNTAX MilliAmps MAX-ACCESS read-only STATUS current DESCRIPTION "The Minimum value for the… |
1.3.6.1.4.1.13742.4.1.10.1.1.10 | dataLogAvgOutletVoltage | 0 | 0 | dataLogAvgOutletVoltage OBJECT-TYPE SYNTAX MilliVolts MAX-ACCESS read-only STATUS current DESCRIPTION "The Average value for th… |
1.3.6.1.4.1.13742.4.1.10.1.1.11 | dataLogMaxOutletVoltage | 0 | 0 | dataLogMaxOutletVoltage OBJECT-TYPE SYNTAX MilliVolts MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum value for th… |
1.3.6.1.4.1.13742.4.1.10.1.1.12 | dataLogMinOutletVoltage | 0 | 0 | dataLogMinOutletVoltage OBJECT-TYPE SYNTAX MilliVolts MAX-ACCESS read-only STATUS current DESCRIPTION "The Minimum value for th… |
1.3.6.1.4.1.13742.4.1.10.1.1.13 | dataLogAvgOutletPowerFactor | 0 | 0 | dataLogAvgOutletPowerFactor OBJECT-TYPE SYNTAX PowerFactorPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "The Avera… |
1.3.6.1.4.1.13742.4.1.10.1.1.14 | dataLogMaxOutletPowerFactor | 0 | 0 | dataLogMaxOutletPowerFactor OBJECT-TYPE SYNTAX PowerFactorPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "The Maxim… |
1.3.6.1.4.1.13742.4.1.10.1.1.15 | dataLogMinOutletPowerFactor | 0 | 0 | dataLogMinOutletPowerFactor OBJECT-TYPE SYNTAX PowerFactorPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "The Minim… |
1.3.6.1.4.1.13742.4.1.10.1.1.16 | dataLogAvgOutletWattHours | 0 | 0 | dataLogAvgOutletWattHours OBJECT-TYPE SYNTAX WattHours MAX-ACCESS read-only STATUS current DESCRIPTION "The Average value for t… |
1.3.6.1.4.1.13742.4.1.10.1.1.17 | dataLogMaxOutletWattHours | 0 | 0 | dataLogMaxOutletWattHours OBJECT-TYPE SYNTAX WattHours MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum value for t… |
1.3.6.1.4.1.13742.4.1.10.1.1.18 | dataLogMinOutletWattHours | 0 | 0 | dataLogMinOutletWattHours OBJECT-TYPE SYNTAX WattHours MAX-ACCESS read-only STATUS current DESCRIPTION "The Minimum value for t… |