Reference record for OID 1.3.6.1.4.1.15.2.109.4


parent
1.3.6.1.4.1.15.2.109 (ss7)
node code
4
node name
ss7Pref2SigPort
dot oid
1.3.6.1.4.1.15.2.109.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xylogics(15) annex(2) ss7(109) ss7Pref2SigPort(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) xylogics(15) annex(2) ss7(109) ss7Pref2SigPort(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) xylogics(15) annex(2) ss7(109) ss7Pref2SigPort(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) xylogics(15) annex(2) ss7(109) ss7Pref2SigPort(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xylogics(15) annex(2) ss7(109) ss7Pref2SigPort(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) xylogics(15) annex(2) ss7(109) ss7Pref2SigPort(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/xylogics/annex/ss7/ss7Pref2SigPort
  • /iso/identified-organization/dod/internet/private/enterprises/xylogics/annex/ss7/ss7Pref2SigPort
  • /iso/org/dod/internet/private/enterprise/xylogics/annex/ss7/ss7Pref2SigPort
  • /iso/org/dod/internet/private/enterprises/xylogics/annex/ss7/ss7Pref2SigPort
  • /iso/iso-identified-organization/dod/internet/private/enterprise/xylogics/annex/ss7/ss7Pref2SigPort
  • /iso/iso-identified-organization/dod/internet/private/enterprises/xylogics/annex/ss7/ss7Pref2SigPort
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/15/2/109/4

    Description by mibdepot

    The TCP port number used on the secondary SS7 gateway.
    The default is 1000. This entry is zero if no redundant
    SS7 gateway is available.
    This MIB object corresponds to the NA/admin parameter
    'pref2_sig_port'.

    Parsed from file xylo-wan.mib.txt
    Company: avaya
    Module: XYLO-WAN-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    ss7Pref2SigPort OBJECT-TYPE SYNTAX INTEGER (1..65534) ACCESS read-write STATUS mandatory DESCRIPTION "The TCP port number used on the secondary SS7 gateway. The default is 1000. This entry is zero if no redundant SS7 gateway is available. This MIB object corresponds to the NA/admin parameter 'pref2_sig_port'." ::= { ss7 4 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.15)

    Barnes Jim

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.15.2.109.4.0 ss7Pref2SigPort 0 0 None

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.15.2.109.1 ss7Pref1SigGateway 1 1 The IP address of the primary SS7 gateway.
    The default value is 0.0.0.0.
    This MIB object corresponds to the NA/admin
    parameter 'pr…
    1.3.6.1.4.1.15.2.109.2 ss7Pref2SigGateway 1 1 The IP address of the primary secondary SS7 gateway.
    This may be zero if a redundant SS7 gateway is not
    available.
    The default val…
    1.3.6.1.4.1.15.2.109.3 ss7Pref1SigPort 1 1 The TCP port number used on the primary SS7 gateway.
    The default is 1000.
    This MIB object corresponds to the NA/admin parameter
    'p…
    1.3.6.1.4.1.15.2.109.5 ss7SigKeepalive 1 1 The maximum time to wait for a packet to be received from
    SS7 server. This value is in seconds. The default value is
    15 seconds.
    T…
    1.3.6.1.4.1.15.2.109.6 ss7CurrentGateway 1 1 The address of the current SS7 server. This can
    change dynamically depending on the state of the
    server.
    1.3.6.1.4.1.15.2.109.7 ss7ConnectionTime 1 1 Time at which this connection was established
    to the current SS7 Gateway.
    1.3.6.1.4.1.15.2.109.8 ss7Registration 1 1 Describes whether the RAS can accept and/or receive
    calls. This is set by the ss7 gateway.
    1.3.6.1.4.1.15.2.109.9 ss7ChanTable 1 5 Table of ss7 Channel information.