swEventTrapLevel OBJECT-TYPE
SYNTAX INTEGER {
none (0),
critical (1),
error (2),
warning (3),
informational (4),
debug (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object specifies the swEventTrap level in
conjunction with an events severity level. When an event
occurs and if its severity level is at or below the value
specified by this object instance, the agent will send
the associated swEventTrap to configured recipients."
View at oid-info.com
Indicates whether the SNMP agent process will
generate a linkDown traps for the failure of
communication links. See rfc1213 for details.
Parsed from file v2.0.1aSW.mib.txt
Company: None
Module: SW-MIB
swAgtTrapSeverityLevel, in absence of
swEventTrapLevel, specifies the Trap Severity Level of each
defined trap recipient host.
This object specifies the swEventTrap level in
conjunction with an event's severity level. When an event
occurs and if its severity level is at or below the value
specified by this object instance, the agent will send
the associated swEventTrap to configured recipients.
Parsed from file SW-MIB.mib
Module: SW-MIB
Automatically extracted from SilkWorm Switch MIBs and RSH Utilities
swEnableLinkDownTraps OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process will generate a linkDown traps for the failure of communication links. See rfc1213 for details." ::= { swTrapFuncCfg 1 }
swEventTrapLevel OBJECT-TYPE SYNTAX INTEGER { none (0), critical (1), error (2), warning (3), informational (4), debug (5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "swAgtTrapSeverityLevel, in absence of swEventTrapLevel, specifies the Trap Severity Level of each defined trap recipient host. This object specifies the swEventTrap level in conjunction with an event's severity level. When an event occurs and if its severity level is at or below the value specified by this object instance, the agent will send the associated swEventTrap to configured recipients." ::= { swEvent 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1588.2.1.1.1.8.1.0 | swEventTrapLevel | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1588.2.1.1.1.8.2 | swEnableLinkUpTraps | 0 | 0 | Indicates whether the SNMP agent process will generate a linkUp trap for the communication links. See rfc1213 for details. |
1.3.6.1.4.1.1588.2.1.1.1.8.3 | swEnablePortAddrSecuViolationTraps | 0 | 0 | Setting this object to disabled(2) will prevent the device from sending 'Address Secured Violation' traps. |
1.3.6.1.4.1.1588.2.1.1.1.8.4 | swEventNumEntries, swEnableLBridgenewRootTraps | 1 | 1 | The number of entries in the Event Table. |
1.3.6.1.4.1.1588.2.1.1.1.8.5 | swEventTable, swEnableLbridgetopologyChangeTraps | 1 | 6 | The table of event entries. |
1.3.6.1.4.1.1588.2.1.1.1.8.6 | swEnableBcastStormAlarmEventTraps | 0 | 0 | Setting this object to disabled(2) will prevent the device from sending 'Broadcast Storm Alarm' traps. |
1.3.6.1.4.1.1588.2.1.1.1.8.7 | swEnableFanFailureEventTraps | 0 | 0 | Setting this object to disabled(2) will prevent the device from sending 'Fan-Failure' traps. |