This table enables the user to set attributes to each alarm.
Setting for a non-existing entry agnCnfgAlrMask,
agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave
for Mask) will add this new entry to the table.
Setting for an existing entry agnCnfgAlrMask/
agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no'
(noAndSave for Mask) so that ALL these objects' values are
'no' , will delete this entry from the table.
For agnCnfgAlrMask, only if [(last saved value=noAndSave)
AND (new value is 'no' or 'noAndSave')] the object's value
is considered 'no' for deleting the entry.
For some products (like MP, MPH, Vmux2100) the Active Alarms are always
part of the table and cannot be removed even if their Mask/Invert/Filter
are No.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This table enables the user to set attributes to each alarm.
Setting for a non-existing entry agnCnfgAlrMask,
agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave
for Mask) will add this new entry to the table.
Setting for an existing entry agnCnfgAlrMask/
agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no'
(noAndSave for Mask) so that ALL these objects' values are
'no' , will delete this entry from the table.
For agnCnfgAlrMask, only if [(last saved value=noAndSave)
AND (new value is 'no' or 'noAndSave')] the object's value
is considered 'no' for deleting the entry.
For some products (like MP, MPH, Vmux2100) the Active Alarms are always
part of the table and cannot be removed even if their Mask/Invert/Filter
are No.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
agnCnfgAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No." ::= { agnCnfgAlarm 2}
agnCnfgAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No." ::= { agnCnfgAlarm 2}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.2.8.2.1 | agnCnfgAlrEntry | 8 | 8 | An entry in table. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.2.8.1 | agnCnfgAlrFilterWindow | 1 | 1 | Window of time, in seconds. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filter… |
1.3.6.1.4.1.164.3.1.2.2.8.3 | agnCnfgAlrReportTable | 1 | 4 | This table enables the user to configure the desired Alarm Reports according to alarms severity. |