The slot to which the net event relates .
Not applicable for time event
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
The slot to which the net event relates .
Not applicable for time event
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
agnCFlipNetEventSlot OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The slot to which the net event relates . Not applicable for time event" ::= {agnCFlipNetEventsEntry 6}
agnCFlipNetEventSlot OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The slot to which the net event relates . Not applicable for time event" ::= {agnCFlipNetEventsEntry 6}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.1.2.5.2.1.1 | agnCFlipNetEventsCnfgIdx | 0 | 0 | Active or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to. |
1.3.6.1.4.1.164.3.1.2.5.2.1.2 | agnCFlipNetEventIdx | 0 | 0 | Entry within the table |
1.3.6.1.4.1.164.3.1.2.5.2.1.3 | agnCFlipNetEventActive | 0 | 0 | Indicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to deleā¦ |
1.3.6.1.4.1.164.3.1.2.5.2.1.4 | agnCFlipNetEventType | 0 | 0 | The Net Event type |
1.3.6.1.4.1.164.3.1.2.5.2.1.5 | agnCFlipNetEventNo | 0 | 0 | The Net Event No. (Bit Index) |
1.3.6.1.4.1.164.3.1.2.5.2.1.7 | agnCFlipNetEventPort | 0 | 0 | The port within the relevant slot. Valid values: - extPrt1(1)..exPrt16(16) - notApplicable(100) - inPrt1(101)..inPrt48(148) |
1.3.6.1.4.1.164.3.1.2.5.2.1.8 | agnCFlipNetEventISD | 0 | 0 | The time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events. |
1.3.6.1.4.1.164.3.1.2.5.2.1.9 | agnCFlipNetEventOSD | 0 | 0 | The time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events. |
1.3.6.1.4.1.164.3.1.2.5.2.1.10 | agnCFlipNetEventDayType | 0 | 0 | The time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event |
1.3.6.1.4.1.164.3.1.2.5.2.1.11 | agnCFlipNetEventStartTime | 0 | 0 | The time event will be activated at this time. The format is hh:mm. |
1.3.6.1.4.1.164.3.1.2.5.2.1.12 | agnCFlipNetEventEndTime | 0 | 0 | The time event will be deactivated at this time. The format is hh:mm. |