This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications Ltd.
Module: DACS-MIB
[Automatically extracted from oidview.com]
prtHSBertPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtHSBertEntry 1}
prtHSBertPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 ." ::= { prtHSBertEntry 1}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.3.3.3.2.1.2 | prtHSBertSlt | 0 | 0 | This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this o… |
1.3.6.1.4.1.164.3.3.3.3.2.1.3 | prtHSBertCountClr | 0 | 0 | Setting this object (to on) initiate bert counter clear operation. Valid only when bert test is active on the specific port. (Ever… |
1.3.6.1.4.1.164.3.3.3.3.2.1.4 | prtHSBertTestResult | 0 | 0 | This object indicates the number of Bit Error Rate indicated during the BERT test. Active only when bert test is running on the s… |