It is triggered when a preset utilization value
is set for a gateway and it has met that utilization.
VARIABLE DEFINITIONS:
1) timeOccurred - time when the alarm occured, in
2) code - bitwise OR of severity, facility, errorCode,
instanceID, severity<<28 | facility<<24 |
errorCode<<16 | instanceid
2) gwID - unique identifier assigned to the gateway.
3) moduleID - The module of the gateway that reports
utilization.
4) percent - The percent of utilization being reported.
5) comment - Any comment sent along with this trap
Severity: INFO/MINOR depending on the preset value.
Parsed from file h323Traps.MIB.txt
Company: None
Module: H323-TRAP-MIB
It is triggered when a preset utilization value
is set for a gateway and it has met that utilization.
VARIABLE DEFINITIONS:
1) timeOccurred - time when the alarm occured, in
2) code - bitwise OR of severity, facility, errorCode,
instanceID, severity<<28 | facility<<24 |
errorCode<<16 | instanceid
2) gwID - unique identifier assigned to the gateway.
3) moduleID - The module of the gateway that reports
utilization.
4) percent - The percent of utilization being reported.
5) comment - Any comment sent along with this trap
Severity: INFO/MINOR depending on the preset value.
Parsed from file H323-TRAP-MIB.mib
Module: H323-TRAP-MIB
Vendor: Lucent Technologies
Module: H323-TRAP-MIB
[Automatically extracted from oidview.com]
h323GatewayUtilization NOTIFICATION-TYPE OBJECTS { timeOccurred, code, gwID, moduleID, percent, comment} STATUS current DESCRIPTION "It is triggered when a preset utilization value is set for a gateway and it has met that utilization. VARIABLE DEFINITIONS: 1) timeOccurred - time when the alarm occured, in
. format 2) code - bitwise OR of severity, facility, errorCode, instanceID, severity<<28 | facility<<24 | errorCode<<16 | instanceid 2) gwID - unique identifier assigned to the gateway. 3) moduleID - The module of the gateway that reports utilization. 4) percent - The percent of utilization being reported. 5) comment - Any comment sent along with this trap Severity: INFO/MINOR depending on the preset value." ::= { h323Traps 1 }
h323GatewayUtilization NOTIFICATION-TYPE OBJECTS { timeOccurred, code, gwID, moduleID, percent, comment} STATUS current DESCRIPTION "It is triggered when a preset utilization value is set for a gateway and it has met that utilization. VARIABLE DEFINITIONS: 1) timeOccurred - time when the alarm occured, in
. format 2) code - bitwise OR of severity, facility, errorCode, instanceID, severity<<28 | facility<<24 | errorCode<<16 | instanceid 2) gwID - unique identifier assigned to the gateway. 3) moduleID - The module of the gateway that reports utilization. 4) percent - The percent of utilization being reported. 5) comment - Any comment sent along with this trap Severity: INFO/MINOR depending on the preset value." ::= { h323Traps 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.1.1198.3.0.0 | h323CSConnectionStatus | 0 | 0 | Indicates the registration status of the device server(registered, unregistered or registration failed). VARIABLE DEFINITIONS: 1) t… |
1.3.6.1.4.1.1751.1.1198.3.0.2 | h323DSError | 0 | 0 | When any error occurs in the device server. VARIABLE DEFINITIONS: 1) timeOccurred - time when the alarm occured, in 2) cod… |
1.3.6.1.4.1.1751.1.1198.3.0.3 | h323UnreachableGateway | 0 | 0 | When any gateway is unreachable . Either the TCP/IP address is wrong or the gateway is down. VARIABLE DEFINITIONS: 1) timeOccurred… |
1.3.6.1.4.1.1751.1.1198.3.0.4 | h323CommandFailed | 0 | 0 | Triggered when any request is failed by the device server. VARIABLE DEFINITIONS: 1) timeOccurred - time when the alarm occured, in… |