Reference record for OID 1.3.6.1.4.1.1751.2.18.2.4.1.19



parent
1.3.6.1.4.1.1751.2.18.2.4.1 (msPortConfigEntry)
node code
19
node name
msLineStatus
dot oid
1.3.6.1.4.1.1751.2.18.2.4.1.19
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) mibs(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) lucent-MIB(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) mibs(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lucent(1751) lucent-MIB(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) mibs(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) lucent-MIB(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) mibs(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lucent(1751) lucent-MIB(2) acMIB(18) equipConfig(2) msPortConfigTable(4) msPortConfigEntry(1) msLineStatus(19)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/mibs/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • /iso/identified-organization/dod/internet/private/enterprise/lucent/lucent-MIB/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/lucent/mibs/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • /iso/org/dod/internet/private/enterprise/lucent/lucent-MIB/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • /iso/org/dod/internet/private/enterprises/lucent/mibs/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • /iso/org/dod/internet/private/enterprises/lucent/lucent-MIB/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lucent/mibs/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lucent/lucent-MIB/acMIB/equipConfig/msPortConfigTable/msPortConfigEntry/msLineStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/1751/2/18/2/4/1/19

    Description by mibdepot

    line status on the port:
    The msLineStatus is a bit map representation.
    It can represent multiple failures (alarms)
    if supported by the card.

    NoAlarm should be set if and only if
    no other flag is set.

    The various bit positions are:
    1: NoAlarm
    2: Loss of Signal

    Parsed from file ac120.my.V07.00.C00.mib.txt
    Company: None
    Module: ACMIB

    Description by circitor

    line status on the port:
    The msLineStatus is a bit map representation.
    It can represent multiple failures (alarms)
    if supported by the card.

    NoAlarm should be set if and only if
    no other flag is set.

    The various bit positions are:
    1: NoAlarm
    2: Loss of Signal

    Parsed from file ACMIB.mib
    Module: ACMIB

    Information by oid_info

    Vendor: Lucent Technologies
    Module: ACMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    msLineStatus OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "line status on the port: The msLineStatus is a bit map representation. It can represent multiple failures (alarms) if supported by the card. NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1: NoAlarm 2: Loss of Signal " DEFVAL { 1 } ::= { msPortConfigEntry 19 }

    Information by circitor

    msLineStatus OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "line status on the port: The msLineStatus is a bit map representation. It can represent multiple failures (alarms) if supported by the card. NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1: NoAlarm 2: Loss of Signal " DEFVAL { 1 } ::= { msPortConfigEntry 19 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.1751)

    Richard Bantel

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.1751)

    Håkon Helmers

    Brothers (22)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.1751.2.18.2.4.1.1 msPortId 0 0 slot/port: SSPP
    1.3.6.1.4.1.1751.2.18.2.4.1.2 msLineCoding 0 0 Line Coding.
    1.3.6.1.4.1.1751.2.18.2.4.1.3 msBaudRate 0 0 baud rate is determined by
    multiplying this number by the
    msBaudRateMultiplier
    1.3.6.1.4.1.1751.2.18.2.4.1.4 msProtocol 0 0 protocol type for serial port
    1.3.6.1.4.1.1751.2.18.2.4.1.5 msEquipmentType 0 0 Equipment type
    1.3.6.1.4.1.1751.2.18.2.4.1.6 msRs232XmitMode 0 0 transmit mode for rs232 DTE/DCE serial port
    1.3.6.1.4.1.1751.2.18.2.4.1.7 msRs232Parity 0 0 parity for rs232 DTE/DCE serial port
    1.3.6.1.4.1.1751.2.18.2.4.1.8 msRs232DataBits 0 0 data bits for rs232 DTE/DCE serial port
    1.3.6.1.4.1.1751.2.18.2.4.1.9 msRs232StopBits 0 0 stop bits for rs232 DTE/DCE serial port
    1.3.6.1.4.1.1751.2.18.2.4.1.10 msTxDataClkSrcForDte 0 0 Transmit data clock source for DTE,
    externalTx in is not valid for rs232.
    This field is ignored if the local side is DCE.
    1.3.6.1.4.1.1751.2.18.2.4.1.11 msTxDataClkSrcForDce 0 0 Transmit data clock source for DCE
    localTiming: a local clock source is used. (e.g., from
    backplane (stratum)
    loopTiming: from rem…
    1.3.6.1.4.1.1751.2.18.2.4.1.12 msRxDataClkSrcForDce 0 0 Receive data clock source for DCE
    localTiming: a local clock source is used. (e.g., from
    backplane (stratum)
    loopTiming: from remo…
    1.3.6.1.4.1.1751.2.18.2.4.1.13 msRxClkPolarity 0 0 Whether or not to reverse the receive clock
    1.3.6.1.4.1.1751.2.18.2.4.1.14 msTxClkPolarity 0 0 Whether or not to reverse the transmit clock
    1.3.6.1.4.1.1751.2.18.2.4.1.15 msKgResync 0 0 Turn KG resync on/off
    1.3.6.1.4.1.1751.2.18.2.4.1.16 msHandshake 0 0 Multiserial Module handshake:
    observed : used with AAL1 to monitor
    RTS/CTS exchange.
    1.3.6.1.4.1.1751.2.18.2.4.1.17 msSpeedAdaption 0 0 The state of allowing speed adaption
    1.3.6.1.4.1.1751.2.18.2.4.1.18 msBitStuffing 0 0 When msBitStuffing is enabled,
    CAC throughput is (1 + 1/7) user throughtput.
    Otherwise the CAC throughput is the same as the user…
    1.3.6.1.4.1.1751.2.18.2.4.1.20 msRxDataPolarity 0 0 Whether or not to reverse the receive data
    1.3.6.1.4.1.1751.2.18.2.4.1.21 msTxDataPolarity 0 0 Whether or not to reverse the transmit data
    1.3.6.1.4.1.1751.2.18.2.4.1.22 msLoopbackConfig 0 0 This variable represents the loopback
    configuration of the Serial port.
    1.3.6.1.4.1.1751.2.18.2.4.1.23 msLOSDetection 0 0 State of detection of LOS by IO card.
    LOS detection is always enabled when msBitStuffing is enabled.
    When the interface is not ci…