Row definition of bridge atm PVC VCC connection
attribution.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Row definition of bridge atm PVC VCC connection
attribution.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
bridgeAtmPvcVccEntry OBJECT-TYPE SYNTAX BridgeAtmPvcVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition of bridge atm PVC VCC connection attribution." INDEX { bridgeAtmPvcVccIfA, bridgeAtmPvcVccIfB, bridgeAtmPvcVccVpiB, bridgeAtmPvcVccVciB } ::= { bridgeAtmPvcVccTable 1 }
bridgeAtmPvcVccEntry OBJECT-TYPE SYNTAX BridgeAtmPvcVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition of bridge atm PVC VCC connection attribution." INDEX { bridgeAtmPvcVccIfA, bridgeAtmPvcVccIfB, bridgeAtmPvcVccVpiB, bridgeAtmPvcVccVciB } ::= { bridgeAtmPvcVccTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.13.1.1 | bridgeAtmPvcVccIfA | 0 | 0 | Interface index for side A, the bridge side, of a bridge-atm PVC VCC connection. Number value is interpreted as an interface of … |
1.3.6.1.4.1.1751.2.18.6.13.1.2 | bridgeAtmPvcVccIfB | 0 | 0 | Interface index for side B, the atm side, of a bridge-atm PVC VCC connection. Number value is interpreted as an interface of the… |
1.3.6.1.4.1.1751.2.18.6.13.1.3 | bridgeAtmPvcVccVpiB | 0 | 0 | VPI value for side B, the atm side, of a bridge-atm PVC VCC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.13.1.4 | bridgeAtmPvcVccVciB | 0 | 0 | VCI value for side B, the atm side, of a bridge-atm PVC VCC connection. Valid range is a number between 0 and 65535. |
1.3.6.1.4.1.1751.2.18.6.13.1.5 | bridgeAtmPvcVccServiceType | 0 | 0 | service type |
1.3.6.1.4.1.1751.2.18.6.13.1.6 | bridgeAtmPvcVccPeakCellRateB2A | 0 | 0 | peak rate - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.13.1.7 | bridgeAtmPvcVccSusCellRateB2A | 0 | 0 | sustained rate - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.13.1.8 | bridgeAtmPvcVccMaxBurstSizeB2A | 0 | 0 | maximum burst size - side B, in cells. |
1.3.6.1.4.1.1751.2.18.6.13.1.9 | bridgeAtmPvcVccRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.13.1.10 | bridgeAtmPvcVccConnectionStatus | 0 | 0 | Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: … |
1.3.6.1.4.1.1751.2.18.6.13.1.11 | bridgeAtmPvcVccDualHomed | 0 | 0 | Does this PVC need a backup Dual homing PVC. |
1.3.6.1.4.1.1751.2.18.6.13.1.12 | bridgeAtmPvcVccViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.13.1.14 | bridgeAtmPvcVccCnfrmTypeB2A | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.13.1.15 | bridgeAtmPvcVccVUNIB | 0 | 0 | VUNI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.13.1.16 | bridgeAtmPvcVccMfsB2A | 0 | 0 | Maximum Frame Size for GFR traffic |
1.3.6.1.4.1.1751.2.18.6.13.1.17 | bridgeAtmPvcVccConnFailureCauseA | 0 | 0 | connestion status reason code |
1.3.6.1.4.1.1751.2.18.6.13.1.18 | bridgeAtmPvcVccConnFailureCauseB | 0 | 0 | connection status reason code |
1.3.6.1.4.1.1751.2.18.6.13.1.19 | bridgeAtmPvcVccOamStatus | 0 | 0 | Indicates the OAM monitoring status of side A. The 3 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only … |
1.3.6.1.4.1.1751.2.18.6.13.1.20 | bridgeAtmPvcVccTrafficShapingA2B | 0 | 0 | Traffic Shaping Support in the A2B direction. |