Row definition of atm connections
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
Row definition of atm connections
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
atmPvcVpcEntry OBJECT-TYPE SYNTAX AtmPvcVpcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition of atm connections" INDEX { atmPvcVpcIfA, atmPvcVpcVpiA, atmPvcVpcIfB, atmPvcVpcVpiB } ::= { atmPvcVpcTable 1 }
atmPvcVpcEntry OBJECT-TYPE SYNTAX AtmPvcVpcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition of atm connections" INDEX { atmPvcVpcIfA, atmPvcVpcVpiA, atmPvcVpcIfB, atmPvcVpcVpiB } ::= { atmPvcVpcTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.2.1.1 | atmPvcVpcIfA | 0 | 0 | Interface index for side A of an ATM-to-ATM PVC VPC connection. Number value is interpreted as an interface of the form, SSPPCCC… |
1.3.6.1.4.1.1751.2.18.6.2.1.2 | atmPvcVpcVpiA | 0 | 0 | VPI value for side A of an ATM-to-ATM PVC VPC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.2.1.3 | atmPvcVpcIfB | 0 | 0 | Interface index for side B of an ATM-to-ATM PVC VPC connection. Number value is interpreted as an interface of the form, SSPPCCC… |
1.3.6.1.4.1.1751.2.18.6.2.1.4 | atmPvcVpcVpiB | 0 | 0 | VPI value for side B of an ATM-to-ATM PVC VPC connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.2.1.5 | atmPvcVpcServiceTypeA2B | 0 | 0 | service type |
1.3.6.1.4.1.1751.2.18.6.2.1.6 | atmPvcVpcSarTypeA2B | 0 | 0 | SAR Type |
1.3.6.1.4.1.1751.2.18.6.2.1.8 | atmPvcVpcPeakCellRateA2B | 0 | 0 | peak rate - side A, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.2.1.9 | atmPvcVpcSusCellRateA2B | 0 | 0 | sustained rate - side A, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.2.1.10 | atmPvcVpcMaxBurstSizeA2B | 0 | 0 | maximum burst size - side A, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.2.1.11 | atmPvcVpcServiceTypeB2A | 0 | 0 | service type |
1.3.6.1.4.1.1751.2.18.6.2.1.12 | atmPvcVpcSarTypeB2A | 0 | 0 | SAR Type |
1.3.6.1.4.1.1751.2.18.6.2.1.14 | atmPvcVpcPeakCellRateB2A | 0 | 0 | peak rate - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.2.1.15 | atmPvcVpcSusCellRateB2A | 0 | 0 | sustained rate - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.2.1.16 | atmPvcVpcMaxBurstSizeB2A | 0 | 0 | maximum burst size - side B, in cell per second. |
1.3.6.1.4.1.1751.2.18.6.2.1.17 | atmPvcVpcType | 0 | 0 | security feature type |
1.3.6.1.4.1.1751.2.18.6.2.1.18 | atmPvcVpcFlow | 0 | 0 | flow type |
1.3.6.1.4.1.1751.2.18.6.2.1.19 | atmPvcVpcRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.2.1.20 | atmPvcVpcConnectionStatus | 0 | 0 | Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: … |
1.3.6.1.4.1.1751.2.18.6.2.1.21 | atmPvcVpcOamStatus | 0 | 0 | Indicates the OAM monitoring status of side A. The 5 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only … |
1.3.6.1.4.1.1751.2.18.6.2.1.22 | atmPvcVpcDualHomed | 0 | 0 | Does this PVC need a backup Dual homing PVC. |
1.3.6.1.4.1.1751.2.18.6.2.1.23 | atmPvcVpcViA | 0 | 0 | VI to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.2.1.24 | atmPvcVpcViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.2.1.25 | atmPvcVpcCnfrmTypeA2B | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.2.1.26 | atmPvcVpcCnfrmTypeB2A | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.2.1.27 | atmPvcVpcVUNIA | 0 | 0 | VUNI Id to associate the Egress part of the B2A connection . |
1.3.6.1.4.1.1751.2.18.6.2.1.28 | atmPvcVpcVUNIB | 0 | 0 | VUNI Id to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.2.1.29 | atmPvcVpcOamStatusB | 0 | 0 | Indicates the Oam monitoring status of side B of an internal connection. Refer to ITU I.610 and Bellcore GR1248-CORE for definiti… |
1.3.6.1.4.1.1751.2.18.6.2.1.30 | atmPvcVpcOAMConnEndPtStatusA | 0 | 0 | Connection endpoint side A status. Valid only at connection endpoint. |
1.3.6.1.4.1.1751.2.18.6.2.1.31 | atmPvcVpcOAMConnEndPtStatusB | 0 | 0 | Connection endpoint side B status. Valid only at connection endpoint. |
1.3.6.1.4.1.1751.2.18.6.2.1.32 | atmPvcVpcOAMConnSegEndPtStatusA | 0 | 0 | Segment endpoint side A status. Valid only at segment/connection endpoints. |
1.3.6.1.4.1.1751.2.18.6.2.1.33 | atmPvcVpcOAMConnSegEndPtStatusB | 0 | 0 | Segment endpoint side B status. Valid only at segment/connection endpoints. |
1.3.6.1.4.1.1751.2.18.6.2.1.34 | atmPvcVpcConnFailureCauseA | 0 | 0 | connestion status reason code |
1.3.6.1.4.1.1751.2.18.6.2.1.35 | atmPvcVpcConnFailureCauseB | 0 | 0 | connection status reason code |
1.3.6.1.4.1.1751.2.18.6.2.1.36 | atmPvcVpcTrafficShapingA2B | 0 | 0 | Traffic Shaping Support in the A2B direction. |
1.3.6.1.4.1.1751.2.18.6.2.1.37 | atmPvcVpcTrafficShapingB2A | 0 | 0 | Traffic Shaping Support in the B2A direction. |