The currently active tests on the interface.
This object is a bit map represented as a sum,
therefore, it can represent multiple tests
simultaneously. The various bit positions are:
1 Latching CSU sequence is being sent
to the remote DSU/CSU
2 Latching DSU sequence is being sent
to the remote DSU/CSU
4 Latching OCU sequence is being to the
remote OCU
8 Non-Latching CSU sequence is being sent
to the remote DSU/CSU
16 Non-Latching DSU sequence is being sent
to the remote DSU/CSU
32 Non-Latching OCU sequence is being sent
to the remote OCU
64 Latching CSU sequence is being sent to
the local DSU/CSU
128 Latching DSU sequence is being sent to
the local DSU/CSU
256 Non-Latching CSU sequence is being sent
to the local DSU/CSU
2**9 Non-Latching DSU sequence is being sent
to the local DSU/CSU
2**10 OCU Loopback is active
2**11 DS-0 Loopback is active
2**12 Line Loopback is active
2**13 Data Loopback is active
2**14 Send all zeros test pattern is active
2**15 Send all ones test pattern is active
2**16 Send 63 test pattern is active
2**17 Send 511 test pattern is active
2**18 Send 2047 test pattern is active
2**19 Monitor all zeros test pattern is active
2**20 Monitor all ones test pattern is active
2**21 Monitor 63 test pattern is active
2**22 Monitor 511 pattern is active
2**23 Monitor 2047 test pattern is active
If no tests are currently active, this object has the
value 0.
Parsed from file pdndce.mib.txt
Company: paradyne
Module: PDNDCE-MIB
Vendor: Paradyne
Module: PDNDCE-MIB (pdndce.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
devOcuActiveTests OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The currently active tests on the interface. This object is a bit map represented as a sum, therefore, it can represent multiple tests simultaneously. The various bit positions are: 1 Latching CSU sequence is being sent to the remote DSU/CSU 2 Latching DSU sequence is being sent to the remote DSU/CSU 4 Latching OCU sequence is being to the remote OCU 8 Non-Latching CSU sequence is being sent to the remote DSU/CSU 16 Non-Latching DSU sequence is being sent to the remote DSU/CSU 32 Non-Latching OCU sequence is being sent to the remote OCU 64 Latching CSU sequence is being sent to the local DSU/CSU 128 Latching DSU sequence is being sent to the local DSU/CSU 256 Non-Latching CSU sequence is being sent to the local DSU/CSU 2**9 Non-Latching DSU sequence is being sent to the local DSU/CSU 2**10 OCU Loopback is active 2**11 DS-0 Loopback is active 2**12 Line Loopback is active 2**13 Data Loopback is active 2**14 Send all zeros test pattern is active 2**15 Send all ones test pattern is active 2**16 Send 63 test pattern is active 2**17 Send 511 test pattern is active 2**18 Send 2047 test pattern is active 2**19 Monitor all zeros test pattern is active 2**20 Monitor all ones test pattern is active 2**21 Monitor 63 test pattern is active 2**22 Monitor 511 pattern is active 2**23 Monitor 2047 test pattern is active If no tests are currently active, this object has the value 0." ::= { devOcuEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1795.2.24.2.6.10.1.1.1 | devOcuIfIndex | 0 | 0 | The index value which uniquely identifies the data port interface to which this entry is applicable. The interface identified by … |
1.3.6.1.4.1.1795.2.24.2.6.10.1.1.2 | devOcuRate | 0 | 0 | This object is used to select the rate for the OCU port. Setting this object to rate56(1) selects the rate for the port as 56 Kb… |
1.3.6.1.4.1.1795.2.24.2.6.10.1.1.3 | devOcuLoopbackDetection | 0 | 0 | This object is used to configure whether the OCU port will respond to network initiated loopbacks. |