| 1.3.6.1.4.1.18.3.4.8.2.1.1 |
wfMcT1Delete | 0 | 0 |
Create/Delete parameter |
| 1.3.6.1.4.1.18.3.4.8.2.1.2 |
wfMcT1Disable | 0 | 0 |
Enable/Disable parameter |
| 1.3.6.1.4.1.18.3.4.8.2.1.3 |
wfMcT1State | 0 | 0 |
Line Driver state variable |
| 1.3.6.1.4.1.18.3.4.8.2.1.4 |
wfMcT1Slot | 0 | 0 |
Instance ID Slot, filled in by driver |
| 1.3.6.1.4.1.18.3.4.8.2.1.5 |
wfMcT1Connector | 0 | 0 |
Instance ID Connector, filled in by driver |
| 1.3.6.1.4.1.18.3.4.8.2.1.6 |
wfMcT1OperationMode | 0 | 0 |
An option to generate and analyze specific test patterns is provided in BERT mode of operation. Only one T1 port can be in BERT m… |
| 1.3.6.1.4.1.18.3.4.8.2.1.7 |
wfMcT1Mtu | 0 | 0 |
MTU parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger … |
| 1.3.6.1.4.1.18.3.4.8.2.1.8 |
wfMcT1MunichVersion | 0 | 0 |
Specifies version number of the MUNICH chip used |
| 1.3.6.1.4.1.18.3.4.8.2.1.9 |
wfMcT1Dsx1LineType | 0 | 0 |
Selects between the two framing formats supported - D4 and ESF. The sailent differences between the two formats are the number of… |
| 1.3.6.1.4.1.18.3.4.8.2.1.10 |
wfMcT1Dsx1ZeroCoding | 0 | 0 |
Selects between the two Zero Code Suppression formats used on the link. In B8ZS coding, any outgoing stream of eight consecutive … |
| 1.3.6.1.4.1.18.3.4.8.2.1.11 |
wfMcT1Dsx1LoopbackConfig | 0 | 0 |
Indicates the loopback configuration of the T1 interface. The interface can be in the following loopback states: Payload loopback… |
| 1.3.6.1.4.1.18.3.4.8.2.1.13 |
wfMcT1Dsx1SetupAlarmThreshold | 0 | 0 |
Specifies setup time for performance failure conditions, in seconds. When a performance defect is present for greater than the ti… |
| 1.3.6.1.4.1.18.3.4.8.2.1.14 |
wfMcT1Dsx1ClearAlarmThreshold | 0 | 0 |
Specifies clear time for performance failure conditions, in seconds. When a performance failure condition has been cleared for gr… |
| 1.3.6.1.4.1.18.3.4.8.2.1.15 |
wfMcT1Dsx1SignalLevel | 0 | 0 |
Specifies T1 transmit power level, in terms of DB. They translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-2… |
| 1.3.6.1.4.1.18.3.4.8.2.1.16 |
wfMcT1LoopbackDisable | 0 | 0 |
The MCT1 link module is capable of detecting loop up and loop down codes received from the far end. This parameter enables or dis… |
| 1.3.6.1.4.1.18.3.4.8.2.1.17 |
wfMcT1Dsx1FDLOperationMode | 0 | 0 |
Select between the two FDL modes of operation. The AT&T mode, 54016 is based on AT&T publication 54015-1989. The ANSI mode, T1403… |
| 1.3.6.1.4.1.18.3.4.8.2.1.18 |
wfMcT1BertTxOutputLevel | 0 | 0 |
Specifies T1 transmit power level, in terms of DB while the T1 port is in BERT mode. The power levels translate into cable length… |
| 1.3.6.1.4.1.18.3.4.8.2.1.19 |
wfMcT1BertTestMode | 0 | 0 |
Selects between the framing formats while in bert mode of operation. |
| 1.3.6.1.4.1.18.3.4.8.2.1.20 |
wfMcT1BertLineCode | 0 | 0 |
Selects between the two Zero Code Suppression formats used on the link while in BERT mode. In B8ZS coding, any outgoing stream of… |
| 1.3.6.1.4.1.18.3.4.8.2.1.21 |
wfMcT1BertTestPattern | 0 | 0 |
When a T1 port is in BERT mode, it is capable of generating a set of known patterns. This paramater selects between those patterns |
| 1.3.6.1.4.1.18.3.4.8.2.1.22 |
wfMcT1BertSendAlarm | 0 | 0 |
Specifies a blue or yellow alarm to be transmitted while in BERT mode. |
| 1.3.6.1.4.1.18.3.4.8.2.1.23 |
wfMcT1DS2282Version | 0 | 0 |
Specifies version number of DS2282 chip |
| 1.3.6.1.4.1.18.3.4.8.2.1.24 |
wfMcT1Restart | 0 | 0 |
Indicates Port gate should be restarted to read new configuration |
| 1.3.6.1.4.1.18.3.4.8.2.1.25 |
wfMcT1Loopback | 0 | 0 |
Selects line or payload loopback to be activated locally |
| 1.3.6.1.4.1.18.3.4.8.2.1.26 |
wfMcT1FDLTargetAddress | 0 | 0 |
Selects between the two FDL target address modes |