Reference record for OID 1.3.6.1.4.1.18.3.5.9.9.6.1



parent
1.3.6.1.4.1.18.3.5.9.9.6 (wfFrSigTable)
node code
1
node name
wfFrSigEntry
dot oid
1.3.6.1.4.1.18.3.5.9.9.6.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfFrameRelay2Group(9) wfFrSigTable(6) wfFrSigEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfFrameRelay2Group(9) wfFrSigTable(6) wfFrSigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfFrameRelay2Group(9) wfFrSigTable(6) wfFrSigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfFrameRelay2Group(9) wfFrSigTable(6) wfFrSigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfFrameRelay2Group(9) wfFrSigTable(6) wfFrSigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfApplication(5) wfWanGroup(9) wfFrameRelay2Group(9) wfFrSigTable(6) wfFrSigEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfFrameRelay2Group/wfFrSigTable/wfFrSigEntry
  • /iso/identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfFrameRelay2Group/wfFrSigTable/wfFrSigEntry
  • /iso/org/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfFrameRelay2Group/wfFrSigTable/wfFrSigEntry
  • /iso/org/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfFrameRelay2Group/wfFrSigTable/wfFrSigEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfFrameRelay2Group/wfFrSigTable/wfFrSigEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfApplication/wfWanGroup/wfFrameRelay2Group/wfFrSigTable/wfFrSigEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/18/3/5/9/9/6/1

    Description by mibdepot

    The entry of FR Signalling MIB table

    Parsed from file fr2.mib.txt
    Company: None
    Module: Wellfleet-FR2-MIB

    Description by circitor

    The entry of FR Signalling MIB table

    Parsed from file Wellfleet-FR2-MIB.mib
    Module: Wellfleet-FR2-MIB

    Information by oid_info

    Vendor: Wellfleet
    Module: Wellfleet-FR2-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    wfFrSigEntry OBJECT-TYPE SYNTAX WfFrSigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The entry of FR Signalling MIB table " INDEX { wfFrSigLineNumber, wfFrSigLLIndex } ::= { wfFrSigTable 1 }

    Information by circitor

    wfFrSigEntry OBJECT-TYPE SYNTAX WfFrSigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " The entry of FR Signalling MIB table " INDEX { wfFrSigLineNumber, wfFrSigLLIndex } ::= { wfFrSigTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.18)

    Caralyn Brown

    Children (21)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.18.3.5.9.9.6.1.1 wfFrSigDelete 0 0 Delete FR Signalling on this interface
    1.3.6.1.4.1.18.3.5.9.9.6.1.2 wfFrSigDisable 0 0 Disable FR Sig on this interface
    1.3.6.1.4.1.18.3.5.9.9.6.1.3 wfFrSigLineNumber 0 0 Logical Line number. This attribute is Instance Id 1
    1.3.6.1.4.1.18.3.5.9.9.6.1.4 wfFrSigLLIndex 0 0 Lower Layer Index. This attribute is Instance Id 2
    1.3.6.1.4.1.18.3.5.9.9.6.1.5 wfFrSigStatus 0 0 Frame Relay Signalling Status
    This is also Q.933 Layer Status.

    STATUS_RUNNING FR Signalling state machine is ready.
    STATUS_FAULT …
    1.3.6.1.4.1.18.3.5.9.9.6.1.6 wfFrSigCircuit 0 0 Circuit number of the FR Signaling Stack (needed?)
    1.3.6.1.4.1.18.3.5.9.9.6.1.7 wfFrSigConformance 0 0 Q.933 Standard Conformance Selection

    FRF4 Frame Relay Forum Implementation Agreement FRF.4
    FRF4_PRIORITY FRF.4 plus suppor…
    1.3.6.1.4.1.18.3.5.9.9.6.1.8 wfFrSigSvcIdleTimer 0 0 SVC Idle timeout value
    Number of seconds in which SVCs are not passing data
    before considered 'idle'.
    1.3.6.1.4.1.18.3.5.9.9.6.1.9 wfFrSigMaxSvcs 0 0 Max number of SVC allowed on this interface
    1.3.6.1.4.1.18.3.5.9.9.6.1.10 wfFrSigSvcDeletePolicy 0 0 SVC Deletion Policy
    ALWAYS always delete idle SVCs
    HEAVY_USE delete idle SVCs when 85% of Max SVCs are open
    NEVER never delete idl…
    1.3.6.1.4.1.18.3.5.9.9.6.1.11 wfFrSigSvcReplacePolicy 0 0 SVC Replacement Policy
    ALWAYS replace an SVC of an equal or lower priority
    IDLE replace an SVC of an equal or lower priority only…
    1.3.6.1.4.1.18.3.5.9.9.6.1.12 wfFrSigT303 0 0 T303 - SETUP msg timer value in seconds
    1.3.6.1.4.1.18.3.5.9.9.6.1.13 wfFrSigT305 0 0 T305 - DISCONNECT timer value
    1.3.6.1.4.1.18.3.5.9.9.6.1.14 wfFrSigT308 0 0 T308 - RELEASE timer value
    1.3.6.1.4.1.18.3.5.9.9.6.1.15 wfFrSigT310 0 0 T310 - CALL PROCEEDING timer value
    Q.931 specifies a default of 30-120 seconds for this timer.
    1.3.6.1.4.1.18.3.5.9.9.6.1.16 wfFrSigT322 0 0 T322 - STATUS ENQUIRY timer value
    1.3.6.1.4.1.18.3.5.9.9.6.1.17 wfFrSigN322 0 0 Number of times STATUS ENQUIRY is retransmitted
    1.3.6.1.4.1.18.3.5.9.9.6.1.18 wfFrSigNumMaxSVCs 0 0 Maximum number of SVCs currently in active state
    1.3.6.1.4.1.18.3.5.9.9.6.1.19 wfFrSigNumConnRej 0 0 Number of SVC creation attempts which were rejected by Switch
    1.3.6.1.4.1.18.3.5.9.9.6.1.20 wfFrSigNumSvcRej 0 0 Number of SVC setup attempts which were rejected by this router
    1.3.6.1.4.1.18.3.5.9.9.6.1.21 wfFrSigNumSvcFailed 0 0 Number of SVC setup attempts which failed due to errors