This variable uniquely identifies the Cell port for which
this table entry applies. It has the same value as the
cellPortIndex variable in the Cell Port Configuration table.
Parsed from file CP300.mib.txt
Company: marconi
Module: AAC3-MIB
Vendor: ADC Kentrox
Module: AAC3-MIB (aac3-140.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
(
1..65535 )
Automatically extracted from www.mibdepot.com
cellTotalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable uniquely identifies the Cell port for which this table entry applies. It has the same value as the cellPortIndex variable in the Cell Port Configuration table." ::= { cellTotalEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.1.13.6.6.4.1.2 | cellTotalBip8s | 0 | 0 | The counter associated with the number of BIP-8 errors encountered by a Cell port in the previous 24 hour interval. |
1.3.6.1.4.1.181.1.13.6.6.4.1.3 | cellTotalPlcpEFSs | 0 | 0 | The counter associated with the number of PLCP Errored Framing Seconds, encountered by a Cell port in the previous 24 hour interv… |
1.3.6.1.4.1.181.1.13.6.6.4.1.4 | cellTotalPlcpSEFSs | 0 | 0 | The counter associated with the number of PLCP Severely Errored Framing Seconds, encountered by a Cell port in the previous 24 ho… |
1.3.6.1.4.1.181.1.13.6.6.4.1.5 | cellTotalPlcpUASs | 0 | 0 | The counter associated with the number of PLCP Unavailable Seconds, encountered by a Cell port in the previous 24 hour interval. |
1.3.6.1.4.1.181.1.13.6.6.4.1.6 | cellTotalInHecErrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of HEC errored cells encountered b… |
1.3.6.1.4.1.181.1.13.6.6.4.1.7 | cellTotalInInvalidCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of VBR cells transmitted by a Cell… |
1.3.6.1.4.1.181.1.13.6.6.4.1.8 | cellTotalInGoodBusyVbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of VBR cells received by a Cell po… |
1.3.6.1.4.1.181.1.13.6.6.4.1.9 | cellTotalInGoodBusyCbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of CBR cells received by a Cell po… |
1.3.6.1.4.1.181.1.13.6.6.4.1.10 | cellTotalOutCgstnTossedCells | 0 | 0 | The counter associated with the number of cells tossed by the rate controller for whatever reason by a Cell port in the previous … |
1.3.6.1.4.1.181.1.13.6.6.4.1.11 | cellTotalOutPcrTossedCells | 0 | 0 | The counter associated with the number of cells tossed by the rate controller for violating the PCR by a Cell port in the previou… |
1.3.6.1.4.1.181.1.13.6.6.4.1.12 | cellTotalOutBusyVbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of VBR cells transmitted by a Cell… |
1.3.6.1.4.1.181.1.13.6.6.4.1.13 | cellTotalOutBusyCbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of CBR cells transmitted by a Cell… |
1.3.6.1.4.1.181.1.13.6.6.4.1.14 | cellTotalInEmptyCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of cells with both VPI and VCI equ… |
1.3.6.1.4.1.181.1.13.6.6.4.1.15 | cellTotalFebes | 0 | 0 | The counter associated with the number of FEBE errors encountered by a Cell port in the previous 24 hour interval. |
1.3.6.1.4.1.181.1.13.6.6.4.1.16 | cellTotalInHecErrCellsExt | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the most significant eight bits of the 40-bit counter associated with the… |
1.3.6.1.4.1.181.1.13.6.6.4.1.17 | cellTotalInInvalidCellsExt | 0 | 0 | The most significant eight bits of the 40-bit counter associated with the number of cells whose VPI/VCI does not match any curren… |
1.3.6.1.4.1.181.1.13.6.6.4.1.18 | cellTotalInGoodBusyVbrCellsExt | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the most significant eight bits of the 40-bit counter associated with the… |
1.3.6.1.4.1.181.1.13.6.6.4.1.19 | cellTotalInGoodBusyCbrCellsExt | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the most significant eight bits of the 40-bit counter associated with the… |
1.3.6.1.4.1.181.1.13.6.6.4.1.20 | cellTotalOutCgstnTossedCellsExt | 0 | 0 | The most significant eight bits of the 40-bit counter associated with the number of cells tossed by the rate controller for whate… |
1.3.6.1.4.1.181.1.13.6.6.4.1.21 | cellTotalOutPcrTossedCellsExt | 0 | 0 | The most significant eight bits of the 40-bit counter associated with the number of cells tossed by the rate controller for viola… |
1.3.6.1.4.1.181.1.13.6.6.4.1.22 | cellTotalOutBusyVbrCellsExt | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the most significant eight bits of the 40-bit counter associated with the… |
1.3.6.1.4.1.181.1.13.6.6.4.1.23 | cellTotalOutBusyCbrCellsExt | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the most significant eight bits of the 40-bit counter associated with the… |
1.3.6.1.4.1.181.1.13.6.6.4.1.24 | cellTotalInEmptyCellsExt | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the most significant eight bits of the 40-bit counter associated with the… |