Reference record for OID 1.3.6.1.4.1.1991.1.1.1.1.11



parent
1.3.6.1.4.1.1991.1.1.1.1 (snChasGen)
node code
11
node name
snChasMediaLeds
dot oid
1.3.6.1.4.1.1991.1.1.1.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) foundry(1991) products(1) switch(1) snChassis(1) snChasGen(1) snChasMediaLeds(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) foundry(1991) products(1) switch(1) snChassis(1) snChasGen(1) snChasMediaLeds(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) foundry(1991) products(1) switch(1) snChassis(1) snChasGen(1) snChasMediaLeds(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) foundry(1991) products(1) switch(1) snChassis(1) snChasGen(1) snChasMediaLeds(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) foundry(1991) products(1) switch(1) snChassis(1) snChasGen(1) snChasMediaLeds(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) foundry(1991) products(1) switch(1) snChassis(1) snChasGen(1) snChasMediaLeds(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/foundry/products/switch/snChassis/snChasGen/snChasMediaLeds
  • /iso/identified-organization/dod/internet/private/enterprises/foundry/products/switch/snChassis/snChasGen/snChasMediaLeds
  • /iso/org/dod/internet/private/enterprise/foundry/products/switch/snChassis/snChasGen/snChasMediaLeds
  • /iso/org/dod/internet/private/enterprises/foundry/products/switch/snChassis/snChasGen/snChasMediaLeds
  • /iso/iso-identified-organization/dod/internet/private/enterprise/foundry/products/switch/snChassis/snChasGen/snChasMediaLeds
  • /iso/iso-identified-organization/dod/internet/private/enterprises/foundry/products/switch/snChassis/snChasGen/snChasMediaLeds
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/1991/1/1/1/1/11

    Information by oid_info

    Vendor: Foundry Networks, Inc.
    Module: FOUNDRY-SN-AGENT-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    snChasMediaLeds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A bit array that contains the value of the front panel media LEDs. This is a packed bit string; each LED is encoded into 1 bit for each switch port. The maximum number of ports in one chassis is 24 that means 24 Ports Media LEDs. The expansion port number always begins from the last main port number. The following shows the meaning of each bit for each switch port: bit value meaning 0 half duplex 1 full duplex The bitmap of LEDs are as following: (Port1) (Port4) (Port8) Bit (Bit0) (Bit3) (Bit7) Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16 Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24 ::= { snChasGen 11 }

    Information by circitor

    snChasMediaLeds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A bit array that contains the value of the front panel media LEDs. This is a packed bit string; each LED is encoded into 1 bit for each switch port. The maximum number of ports in one chassis is 24 that means 24 Ports Media LEDs. The expansion port number always begins from the last main port number. The following shows the meaning of each bit for each switch port: bit value meaning 0 half duplex 1 full duplex The bitmap of LEDs are as following: (Port1) (Port4) (Port8) Bit (Bit0) (Bit3) (Bit7) Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16 Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24 ::= { snChasGen 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.1991)

    Kwong Raymond

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.1991.1.1.1.1.11.0 snChasMediaLeds 0 0 None

    Brothers (25)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.1991.1.1.1.1.1 snChasType 1 1 The chassis type represents the type
    of Foundry product being managed.
    1.3.6.1.4.1.1991.1.1.1.1.2 snChasSerNum 1 1 The serial number of the chassis. If the
    serial number is unknown or unavailable then
    the value should be a zero length string.
    1.3.6.1.4.1.1991.1.1.1.1.3 snChasPwrSupplyStatus 1 1 A bit array that contains the value of the
    Chassis Power Supplies. This is a packed bit string;
    the 2 power supplies status are e…
    1.3.6.1.4.1.1991.1.1.1.1.4 snChasFanStatus 1 1 A bit array that contains the value of the
    fan status. This is a packed bit string. The
    status of each fan is encoded into one bi…
    1.3.6.1.4.1.1991.1.1.1.1.5 snChasMainBrdDescription 1 1 The main board description string. (It is obsoleted for Chassis Product)
    1.3.6.1.4.1.1991.1.1.1.1.6 snChasMainPortTotal 1 1 The total number of ports for the main board. (It is obsoleted for Chassis Product)
    1.3.6.1.4.1.1991.1.1.1.1.7 snChasExpBrdDescription 1 1 The expansion board description string. Expansion
    board are those boards attaching on the main board.
    (It is obsoleted for Chassi…
    1.3.6.1.4.1.1991.1.1.1.1.8 snChasExpPortTotal 1 1 The total number of ports for the expansion board.
    (It is obsoleted for Chassis Product)
    1.3.6.1.4.1.1991.1.1.1.1.9 snChasStatusLeds 1 1 None
    1.3.6.1.4.1.1991.1.1.1.1.10 snChasTrafficLeds 1 1 None
    1.3.6.1.4.1.1991.1.1.1.1.12 snChasEnablePwrSupplyTrap 1 1 Indicates whether the SNMP agent process is
    permitted to generate power supply failure traps.
    1.3.6.1.4.1.1991.1.1.1.1.13 snChasMainBrdId 1 1 The main board identifier, which can uniquely identify a board
    type. It is an encoded octet string with the following meaning:
    oc…
    1.3.6.1.4.1.1991.1.1.1.1.14 snChasExpBrdId 1 1 The expansion board identifier. Expansion board are those
    boards attaching on the main board. It is an encoded octet
    string with …
    1.3.6.1.4.1.1991.1.1.1.1.15 snChasSpeedLeds 1 1 None
    1.3.6.1.4.1.1991.1.1.1.1.16 snChasEnableFanTrap 1 1 Indicates whether the SNMP agent process is
    permitted to generate fan failure traps.
    1.3.6.1.4.1.1991.1.1.1.1.17 snChasIdNumber 1 1 An administratively-assigned chassis identity number,
    used by inventory control.
    1.3.6.1.4.1.1991.1.1.1.1.18 snChasActualTemperature 1 1 Temperature of the chassis. Each unit is 0.5 degrees Celcius.
    Only management module built with temperature sensor hardware
    is ap…
    1.3.6.1.4.1.1991.1.1.1.1.19 snChasWarningTemperature 1 1 Actual temperature higher than this threshold value will trigger
    the switch to send a temperature warning trap. Each unit is 0.5…
    1.3.6.1.4.1.1991.1.1.1.1.20 snChasShutdownTemperature 1 1 Actual temperature higher than this threshold value will shutdown
    a partial of the switch hardware to cool down the system. Each…
    1.3.6.1.4.1.1991.1.1.1.1.21 snChasEnableTempWarnTrap 1 1 Indicates whether the SNMP agent process is
    permitted to generate temperature warning traps.
    1.3.6.1.4.1.1991.1.1.1.1.22 snChasFlashCard 1 1 A bit array that contains the value of the
    flash card status. This is a packed bit string. The
    status of each flash card is encod…
    1.3.6.1.4.1.1991.1.1.1.1.23 snChasFlashCardLeds 1 1 A bit array that contains the value of the
    flash card LEDs. This is a packed bit string;
    each LED is encoded into 1 bit for each …
    1.3.6.1.4.1.1991.1.1.1.1.24 snChasNumSlots 1 1 Number of slots of the chassis.
    1.3.6.1.4.1.1991.1.1.1.1.25 snChasArchitectureType 1 1 Architecture type.
    1.3.6.1.4.1.1991.1.1.1.1.26 snChasProductType 1 1 Product type.