Voltage threshold entries
Parsed from file RTRSAAG.MIB.txt
Company: ibm
Module: RSA-MIB
Vendor: IBM
Module: RSA-MIB (RTRSAAG.MIB)
Type: ENTRY
Access: not-accessible
Syntax: VoltageThresholdsEntry
Automatically extracted from www.mibdepot.com
voltageThresholdsEntry OBJECT-TYPE SYNTAX VoltageThresholdsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voltage threshold entries" INDEX { voltageThresholdEntryIndex } ::= { voltageThresholdsTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.1 | voltageThresholdEntryIndex | 0 | 0 | Index for voltage threshold entry. |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.2 | voltageThresholdEntryName | 0 | 0 | Voltage threshold entry null terminated string that contains the power supply's name, for example '+5V'. |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.3 | voltageThresholdEntryCurrentValue | 0 | 0 | Voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' … |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.4 | voltageThresholdEntryHardShutdownHighValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage rises above this value the system will be powered off immediately… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.5 | voltageThresholdEntrySoftShutdownHighValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage rises above this value the system will be powered off after the O… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.6 | voltageThresholdEntryWarningHighValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be g… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.7 | voltageThresholdEntryWarningResetHighValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage rises above this value and if a warning alert/event had previousl… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.8 | voltageThresholdEntryHardShutdownLowValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage drops below this value the system will be powered off immediately… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.9 | voltageThresholdEntrySoftShutdownLowValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage drops below this value the system will be powered off after the O… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.10 | voltageThresholdEntryWarningLowValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be g… |
1.3.6.1.4.1.2.3.51.1.2.20.2.1.1.11 | voltageThresholdEntryWarningResetLowValue | 0 | 0 | Voltage threshold reading expressed in Volts(V). If the voltage drops below this value and if a warning alert/event had previousl… |