Analysis polling time. Polling units are decimal values
appended by the unit: d - day, h - hour, m - minute,
s - second, u - millisecond. If no unit is appended, the
value is minutes. Multiple values/units are allowed
(i.e. 1h45m = 1 hour, 45 minutes).
The default is 1 minute. This polling value is used only
by the MIB variable polling center for retrieval of the
local or remote MIB variable for caching. This is required
so that the MIB variable values are cached and not requested
with GET requests when the expression is evaluated.
Parsed from file ibm-sysmon6k.mib.txt
Company: None
Module: SYSMON6K-MIB
Analysis polling time. Polling units are decimal values
appended by the unit: d - day, h - hour, m - minute,
s - second, or u - millisecond. If no unit is appended,
the value is minutes. Multiple values/units are allowed
(i.e. 1h45m = 1 hour, 45 minutes).
The default and minimum poll time is 1 minute. This polling
value is used only by the MIB variable polling center for
retrieval of the local or remote MIB variable for caching.
This is required so that the MIB variable values are cached
and not requested with GET requests when the expression is
evaluated.
Parsed from file MIDLEVELMGR-MIB.mib
Module: MIDLEVELMGR-MIB
Vendor: IBM
Module: MIDLEVELMGR-MIB
[Automatically extracted from oidview.com]
sm6kAnalysisPollTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Analysis polling time. Polling units are decimal values appended by the unit: d - day, h - hour, m - minute, s - second, u - millisecond. If no unit is appended, the value is minutes. Multiple values/units are allowed (i.e. 1h45m = 1 hour, 45 minutes). The default is 1 minute. This polling value is used only by the MIB variable polling center for retrieval of the local or remote MIB variable for caching. This is required so that the MIB variable values are cached and not requested with GET requests when the expression is evaluated." ::= { sm6kAnalysisEntry 6 }
smMlmAnalysisPollTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS obsolete DESCRIPTION "Analysis polling time. Polling units are decimal values appended by the unit: d - day, h - hour, m - minute, s - second, or u - millisecond. If no unit is appended, the value is minutes. Multiple values/units are allowed (i.e. 1h45m = 1 hour, 45 minutes). The default and minimum poll time is 1 minute. This polling value is used only by the MIB variable polling center for retrieval of the local or remote MIB variable for caching. This is required so that the MIB variable values are cached and not requested with GET requests when the expression is evaluated." ::= { smMlmAnalysisEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.12.6.1.1.1 | smMlmAnalysisState, sm6kAnalysisState | 0 | 0 | State for the analysis operation: disabled (1), invalid (2), or enabled (3). |
1.3.6.1.4.1.2.6.12.6.1.1.2 | smMlmAnalysisName, sm6kAnalysisName | 0 | 0 | Analysis name for use as a label and row instance. The selection of a row in the table uses the analysis name as the instance for… |
1.3.6.1.4.1.2.6.12.6.1.1.3 | smMlmAnalysisDescription, sm6kAnalysisDescription | 0 | 0 | Analysis description for the analysis operation. |
1.3.6.1.4.1.2.6.12.6.1.1.4 | smMlmAnalysisOwnerID, sm6kAnalysisOwnerID | 0 | 0 | Owner ID (IP address or hostname) who generated the command entry. This must be initialized by the user. |
1.3.6.1.4.1.2.6.12.6.1.1.5 | smMlmAnalysisLocalRemoteMIBVariableExpression, sm6kAnalysisLocalRemoteMIBVariableExpression | 0 | 0 | Analysis MIB variable expression. The expression can be any expression comprised of local or remote node MIB variables with the … |
1.3.6.1.4.1.2.6.12.6.1.1.7 | smMlmAnalysisResultIndex, sm6kAnalysisResultIndex | 0 | 0 | Index to point to command output result type. The index defines how the expression is evaluated, either using signed arithmetic … |
1.3.6.1.4.1.2.6.12.6.1.1.8 | smMlmAnalysisIntegerResult, sm6kAnalysisIntegerResult | 0 | 0 | Integer result based on signed arithmetic. |
1.3.6.1.4.1.2.6.12.6.1.1.9 | smMlmAnalysisCounterResult, sm6kAnalysisCounterResult | 0 | 0 | Counter result based on unsigned arithmetic; this wraps at the maximum or minimum value. |
1.3.6.1.4.1.2.6.12.6.1.1.10 | smMlmAnalysisGaugeResult, sm6kAnalysisGaugeResult | 0 | 0 | Gauge result based on unsigned arithmetic; this latches at the maximum or minimum value. |
1.3.6.1.4.1.2.6.12.6.1.1.11 | smMlmAnalysisDisplayStringResult, sm6kAnalysisDisplayStringResult | 0 | 0 | Display result as a displayable string. This string is generated based on the ResultIndex for the type of the resultant expressi… |
1.3.6.1.4.1.2.6.12.6.1.1.12 | smMlmAnalysisReturnCode, sm6kAnalysisReturnCode | 0 | 0 | Return code from the evaluation of the expression. |
1.3.6.1.4.1.2.6.12.6.1.1.13 | smMlmAnalysisStandardError, sm6kAnalysisStandardError | 0 | 0 | Standard error output from the evaluation of the expression. |