Reference record for OID 1.3.6.1.4.1.2.6.2.10.1.1.6



parent
1.3.6.1.4.1.2.6.2.10.1.1 (ibmpppLinkControlEntry)
node code
6
node name
ibmpppLinkRemoteMRU
dot oid
1.3.6.1.4.1.2.6.2.10.1.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) ibmProd(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) prod(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) ibmProd(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) prod(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) ibmProd(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) prod(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) ibmProd(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) prod(6) ibm6611(2) ibmppp(10) ibmpppLinkControlTable(1) ibmpppLinkControlEntry(1) ibmpppLinkRemoteMRU(6)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/ibm/ibmProd/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • /iso/identified-organization/dod/internet/private/enterprise/ibm/prod/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/ibm/ibmProd/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • /iso/org/dod/internet/private/enterprise/ibm/prod/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • /iso/org/dod/internet/private/enterprises/ibm/ibmProd/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • /iso/org/dod/internet/private/enterprises/ibm/prod/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ibm/ibmProd/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ibm/prod/ibm6611/ibmppp/ibmpppLinkControlTable/ibmpppLinkControlEntry/ibmpppLinkRemoteMRU
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2/6/2/10/1/1/6

    Description by mibdepot

    What this node believes is the MRU for the node on the
    other end of the link. See section 2.1, page 2, 'Maximum
    Receive Unit' of RFC 1172. Changing this object will
    immediately cause the local node to use the new MRU when
    transmitting packets. If this number is increased, then
    the sender MAY elect to use the new MRU. If the MRU is
    decreased then the sender MUST use the new MRU.

    Parsed from file ibm6611.mib.txt
    Company: None
    Module: IBM6611-MIB

    Description by circitor

    What this node believes is the MRU for the node on the
    other end of the link. See section 2.1, page 2, 'Maximum
    Receive Unit' of RFC 1172. Changing this object will
    immediately cause the local node to use the new MRU when
    transmitting packets. If this number is increased, then
    the sender MAY elect to use the new MRU. If the MRU is
    decreased then the sender MUST use the new MRU.

    Parsed from file IBM6611-MIB.mib
    Module: IBM6611-MIB

    Information by oid_info

    Vendor: IBM
    Module: IBM6611-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    ibmpppLinkRemoteMRU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "What this node believes is the MRU for the node on the other end of the link. See section 2.1, page 2, 'Maximum Receive Unit' of RFC 1172. Changing this object will immediately cause the local node to use the new MRU when transmitting packets. If this number is increased, then the sender MAY elect to use the new MRU. If the MRU is decreased then the sender MUST use the new MRU." ::= { ibmpppLinkControlEntry 6 }

    Information by circitor

    ibmpppLinkRemoteMRU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "What this node believes is the MRU for the node on the other end of the link. See section 2.1, page 2, 'Maximum Receive Unit' of RFC 1172. Changing this object will immediately cause the local node to use the new MRU when transmitting packets. If this number is increased, then the sender MAY elect to use the new MRU. If the MRU is decreased then the sender MUST use the new MRU." ::= { ibmpppLinkControlEntry 6 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2)

    Bob Moore

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2.6.2.10.1.1.1 ibmpppLinkControlIndex 0 0 A unique value for each PPP link. Its value ranges
    between 1 and the value of ifNumber. The interface
    identified by a particular …
    1.3.6.1.4.1.2.6.2.10.1.1.2 ibmpppLinkCRCSize 0 0 Number of bits used in the CRC on this link. See section
    3.1, 'Frame Check Sequence (FCS) Field' on page 5 of
    RFC 1171. Setting…
    1.3.6.1.4.1.2.6.2.10.1.1.3 ibmpppLinkRestartTimerValue 0 0 The value used for the Restart Timer. It is in units of
    hundredths of a second. See section 4.3, 'Timers and
    Counters' on page 2…
    1.3.6.1.4.1.2.6.2.10.1.1.4 ibmpppLinkMaxRestarts 0 0 The Max-Restarts parameter described in section 4.3,
    'Timers and Counters' on page 20 of RFC 1171.
    1.3.6.1.4.1.2.6.2.10.1.1.5 ibmpppLinkLocalMRU 0 0 The MRU (Maximum Receive Unit) of this node on the link.
    See section 2.1, page 2, 'Maximum Receive Unit' of
    RFC 1172. Changing t…
    1.3.6.1.4.1.2.6.2.10.1.1.7 ibmpppLinkLocalACCMap 0 0 The (ACC) Asynchronous-Control-Character-Map for this
    node. This is the ACC Map that the node on the other end
    of the link will …
    1.3.6.1.4.1.2.6.2.10.1.1.8 ibmpppLinkRemoteACCMap 0 0 The (ACC) Asynchronous-Control-Character-Map that this
    node uses when building a packet to send to the node on
    the other end of t…
    1.3.6.1.4.1.2.6.2.10.1.1.9 ibmpppLinkMagicLoopCount 0 0 The number of times that this node will do a Magic Number
    Configuration before deciding that the link is looped
    back. 0 indicate…
    1.3.6.1.4.1.2.6.2.10.1.1.10 ibmpppLinkCommand 0 0 See section 4.14 on page 13 of RFC 1171.
    Reading from this variable will return no-op(1).

    The IBM 6611 Network Processor always p…