The total number of Forwarding Database entries,
which have been or would have been learnt, but
have been discarded due to a lack of space to
store them in the Forwarding Database. If this
counter is increasing, it indicates that the
Forwarding Database is regularly becoming full (a
condition which has unpleasant performance effects
on the subnetwork). If this counter has a
significant value but is not presently increasing,
it indicates that the problem has been occurring
but is not persistent.
Parsed from file ibm6611.mib.txt
Company: None
Module: IBM6611-MIB
The total number of Forwarding Database entries,
which have been or would have been learnt, but
have been discarded due to a lack of space to
store them in the Forwarding Database. If this
counter is increasing, it indicates that the
Forwarding Database is regularly becoming full (a
condition which has unpleasant performance effects
on the subnetwork). If this counter has a
significant value but is not presently increasing,
it indicates that the problem has been occurring
but is not persistent.
Parsed from file IBM6611-MIB.mib
Module: IBM6611-MIB
Vendor: IBM
Module: IBM6611-MIB
[Automatically extracted from oidview.com]
ibmdot1dTpLearnedEntryDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Forwarding Database entries, which have been or would have been learnt, but have been discarded due to a lack of space to store them in the Forwarding Database. If this counter is increasing, it indicates that the Forwarding Database is regularly becoming full (a condition which has unpleasant performance effects on the subnetwork). If this counter has a significant value but is not presently increasing, it indicates that the problem has been occurring but is not persistent." REFERENCE "P802.1d/D9, July 14, 1989: Section 6.7.1.1.3" ::= { ibmdot1dTp 1 }
ibmdot1dTpLearnedEntryDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Forwarding Database entries, which have been or would have been learnt, but have been discarded due to a lack of space to store them in the Forwarding Database. If this counter is increasing, it indicates that the Forwarding Database is regularly becoming full (a condition which has unpleasant performance effects on the subnetwork). If this counter has a significant value but is not presently increasing, it indicates that the problem has been occurring but is not persistent." REFERENCE "P802.1d/D9, July 14, 1989: Section 6.7.1.1.3" ::= { ibmdot1dTp 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.2.15.3.1.0 | ibmdot1dTpLearnedEntryDiscards | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.2.15.3.2 | ibmdot1dTpAgingTime | 1 | 1 | The timeout period in seconds for aging out dynamically learned forwarding information. The IBM 6611 Network Processor obtains th… |
1.3.6.1.4.1.2.6.2.15.3.3 | ibmdot1dTpFdbTable | 1 | 4 | A table that contains information about unicast entries for which the bridge has forwarding and/or filtering information. This i… |
1.3.6.1.4.1.2.6.2.15.3.4 | ibmdot1dTpPortTable | 1 | 6 | A table that contains information about every port that is associated with this transparent bridge. |