Reference record for OID 1.3.6.1.4.1.2.6.2.3.1.3.1



parent
1.3.6.1.4.1.2.6.2.3.1.3 (cylinkConfigTable)
node code
1
node name
cylinkConfigEntry
dot oid
1.3.6.1.4.1.2.6.2.3.1.3.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) ibmProd(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) prod(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) ibmProd(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ibm(2) prod(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) ibmProd(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) prod(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) ibmProd(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ibm(2) prod(6) ibm6611(2) ibmDSUs(3) cylink(1) cylinkConfigTable(3) cylinkConfigEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/ibm/ibmProd/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprise/ibm/prod/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/ibm/ibmProd/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • /iso/org/dod/internet/private/enterprise/ibm/prod/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • /iso/org/dod/internet/private/enterprises/ibm/ibmProd/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • /iso/org/dod/internet/private/enterprises/ibm/prod/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ibm/ibmProd/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ibm/prod/ibm6611/ibmDSUs/cylink/cylinkConfigTable/cylinkConfigEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2/6/2/3/1/3/1

    Description by mibdepot

    An entry in the cylink Configuration table.

    Parsed from file ibm6611.mib.txt
    Company: None
    Module: IBM6611-MIB

    Description by circitor

    An entry in the cylink Configuration table.

    Parsed from file IBM6611-MIB.mib
    Module: IBM6611-MIB

    Information by oid_info

    Vendor: IBM
    Module: IBM6611-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    cylinkConfigEntry OBJECT-TYPE SYNTAX CYLINKConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the cylink Configuration table." INDEX { cylinkConfigIndex } ::= { cylinkConfigTable 1 }

    Information by circitor

    cylinkConfigEntry OBJECT-TYPE SYNTAX CYLINKConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the cylink Configuration table." INDEX { cylinkConfigIndex } ::= { cylinkConfigTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2)

    Bob Moore

    Children (22)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2.6.2.3.1.3.1.1 cylinkConfigIndex 0 0 The index value which uniquely identifies the
    CSU to which this entry is applicable. The
    CSU identified by a particular value of
    t…
    1.3.6.1.4.1.2.6.2.3.1.3.1.2 cylinkSerialNumber 0 0 The manufacturer's serial number of this CSU.
    1.3.6.1.4.1.2.6.2.3.1.3.1.3 cylinkSoftwareVersion 0 0 The version number of the microcode running in the CSU.
    1.3.6.1.4.1.2.6.2.3.1.3.1.4 cylinkDTEFraming 0 0 The DTE framing selected (D4, or ESF). Framing conversion is
    automatically performed at both ends if the DTE is D4 framed and
    th…
    1.3.6.1.4.1.2.6.2.3.1.3.1.5 cylinkNetworkFraming 0 0 The network framing selected (D4, or ESF). Framing conversion is
    automatically performed at both ends if the DTE is D4 framed a…
    1.3.6.1.4.1.2.6.2.3.1.3.1.6 cylinkDTEDS1Mode 0 0 The DTE DS-1 mode selected (B8ZS, or AMI).
    1.3.6.1.4.1.2.6.2.3.1.3.1.7 cylinkNetworkDS1Mode 0 0 The network DS-1 mode selected (B8ZS, or AMI).
    1.3.6.1.4.1.2.6.2.3.1.3.1.8 cylinkOnesResponsibility 0 0 The component selected for Ones Density Responsibility (DTE,
    or CSU.
    1.3.6.1.4.1.2.6.2.3.1.3.1.9 cylinkOnesControl 0 0 The Ones Density Control selected (LSB 24, D4 FRM, or ESF DL).
    1.3.6.1.4.1.2.6.2.3.1.3.1.10 cylinkZeroProtection 0 0 The Consecutive Zero Control selected (15, or 80).
    This determines the the maximum number of consecutive
    zeros allowed in the dat…
    1.3.6.1.4.1.2.6.2.3.1.3.1.11 cylinkClockSource 0 0 The transmit clock source selected for NRZ DIUs
    (network, DTE, an external clock, or the CSU's
    internal clock).
    1.3.6.1.4.1.2.6.2.3.1.3.1.12 cylinkClockFrequency 0 0 The external clock frequency selected (56 kHz, 256 kHz,
    1.344 MHz, 1.544 MHz).
    1.3.6.1.4.1.2.6.2.3.1.3.1.13 cylinkClockBackup 0 0 The transmit clock backup source selected for NRZ DIUs
    (network, DTE, an external clock, or the CSU's internal
    clock).
    1.3.6.1.4.1.2.6.2.3.1.3.1.14 cylinkDIUFrequency 0 0 The DIU frequency selected for NRZ DIUs
    (767 kbps, 1.244 Mbps, 1.528 Mbps, 1.536 Mbps).
    1.3.6.1.4.1.2.6.2.3.1.3.1.15 cylinkDIUTiming 0 0 The DIU transmit timing selected for NRZ DIUs
    (Send Timing, or Terminal Timing).
    1.3.6.1.4.1.2.6.2.3.1.3.1.16 cylinkDialoutCapability 0 0 The DIU dial-out capability selected (polled,
    tone, or pulse).
    1.3.6.1.4.1.2.6.2.3.1.3.1.17 cylinkDialoutHoldoff 0 0 The mininum time, in minutes, between successful
    CSU-to-NMS connections to report alarm conditions.
    1.3.6.1.4.1.2.6.2.3.1.3.1.18 cylinkPrimaryPhone 0 0 The primary telephone number used by by the CSU to contact
    the NMS.
    1.3.6.1.4.1.2.6.2.3.1.3.1.19 cylinkSecondaryPhone 0 0 The secondary telephone number used by by the CSU
    to contact the NMS.
    1.3.6.1.4.1.2.6.2.3.1.3.1.20 cylinkAlarmRepeatTime 0 0 The interval, in minutes, that the CSU will insert
    duplicate messages in the alarm queue for persistant
    alarm conditions.
    1.3.6.1.4.1.2.6.2.3.1.3.1.21 cylinkESThreshold 0 0 The threshold, in seconds, for the errored second
    value in the current 15-minute interval.
    1.3.6.1.4.1.2.6.2.3.1.3.1.22 cylinkSecondaryContact 0 0 The state of the CSU secondary contact (open or closed).