Increment Counter by one for each carrier event whose ActivityDuration
is greater than ShortEventMaxTime and less than RuntMaxTime.
RuntMaxTime is greater than 53.2uS and less than 56.0uS.
An event whose length is greater than 7.4uS but less than 8.2uS shall
increment either the ShortEvent object or the Runts object but not both.
A non-collision event greater than 53.2uS but less than 56.0uS may or may
not be counted as a runt. A non-collision event greater than or equal to
56.0uS shall not be counted as a runt. RuntMaxTime has tolerances included
to provide for circuit losses between a conformance test point at the AUI
and the measurement point within the state machine.
Note: Runts do not indicate a problem in the network. The approximate
minimum time for Counter rollover is 16 hours.
Parsed from file IBM8224.MIB.txt
Company: ibm
Module: IBM-8224-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
ibm8224ExtendedRptrRunts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Increment Counter by one for each carrier event whose ActivityDuration is greater than ShortEventMaxTime and less than RuntMaxTime. RuntMaxTime is greater than 53.2uS and less than 56.0uS. An event whose length is greater than 7.4uS but less than 8.2uS shall increment either the ShortEvent object or the Runts object but not both. A non-collision event greater than 53.2uS but less than 56.0uS may or may not be counted as a runt. A non-collision event greater than or equal to 56.0uS shall not be counted as a runt. RuntMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note: Runts do not indicate a problem in the network. The approximate minimum time for Counter rollover is 16 hours." ::= { ibm8224ExtendedRptrInfo 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.39.9.5.0 | ibm8224ExtendedRptrRunts | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.39.9.1 | ibm8224ExtendedRptrFCSErrors | 1 | 1 | Increment Counter by one for each frame with FCSError and without FramingError and whose OctetCount is greater than or equal to m… |
1.3.6.1.4.1.2.6.39.9.2 | ibm8224ExtendedRptrAlignmentErrors | 1 | 1 | Increment Counter by one for each frame with FCSError and FramingError and whose octetCount is greater than or equal to minFrame… |
1.3.6.1.4.1.2.6.39.9.3 | ibm8224ExtendedRptrFramesTooLong | 1 | 1 | Increment Counter by one for each frame whose OctetCount is greater than maxFrameSize. Note: The approximate minimum time betwee… |
1.3.6.1.4.1.2.6.39.9.4 | ibm8224ExtendedRptrShortEvents | 1 | 1 | Increment Counter by one for each carrier event whose ActivityDuration is greater than ShortEventMinTime and less than ShortEven… |
1.3.6.1.4.1.2.6.39.9.6 | ibm8224ExtendedRptrLateEvents | 1 | 1 | Increment Counter by one for each carrier event in which the CollIn(X) variable transitions to the value SQE while the activity … |
1.3.6.1.4.1.2.6.39.9.7 | ibm8224ExtendedRptrVeryLongEvents | 1 | 1 | The veryLongEvents object counts the number of times a packet has been received by this port that was so long that the repeater … |
1.3.6.1.4.1.2.6.39.9.8 | ibm8224ExtendedRptrDataRateMismatches | 1 | 1 | The dataRateMismatches object counts the number of times that a packet has been received by this port with the transmission freq… |