This object identifies the source of the data for
which protocol distribution data is collected. This
source can be any interface on this device. In order
to identify a particular interface, this object shall identify
the instance of the ifIndex object, for the desired
interface. For example, if an entry were to receive
data from interface #1, this object would be set to
ifIndex.1.
This object may not be modified if the associated
protocolDistControlStatus object is equal to valid(1).
Parsed from file ibm-rmonitor.mib.txt
Company: None
Module: RMONitor-MIB
This object identifies the source of the data for
which protocol distribution data is collected. This
source can be any interface on this device. In order
to identify a particular interface, this object shall identify
the instance of the ifIndex object, for the desired
interface. For example, if an entry were to receive
data from interface #1, this object would be set to
ifIndex.1.
This object may not be modified if the associated
protocolDistControlStatus object is equal to valid(1).
Parsed from file RMONitor-MIB.mib
Module: RMONitor-MIB
Vendor: IBM
Module: RMONitor-MIB
[Automatically extracted from oidview.com]
protocolDistControlDataSource OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies the source of the data for which protocol distribution data is collected. This source can be any interface on this device. In order to identify a particular interface, this object shall identify the instance of the ifIndex object, for the desired interface. For example, if an entry were to receive data from interface #1, this object would be set to ifIndex.1. This object may not be modified if the associated protocolDistControlStatus object is equal to valid(1)." ::= { protocolDistControlEntry 2 }
protocolDistControlDataSource OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies the source of the data for which protocol distribution data is collected. This source can be any interface on this device. In order to identify a particular interface, this object shall identify the instance of the ifIndex object, for the desired interface. For example, if an entry were to receive data from interface #1, this object would be set to ifIndex.1. This object may not be modified if the associated protocolDistControlStatus object is equal to valid(1)." ::= { protocolDistControlEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.6.45.2.1.1.1 | protocolDistControlIndex | 0 | 0 | None |
1.3.6.1.4.1.2.6.45.2.1.1.3 | protocolDistControlLastDeleteTime | 0 | 0 | None |
1.3.6.1.4.1.2.6.45.2.1.1.4 | protocolDistControlOwner | 0 | 0 | The entity that created this entry in the protocol distribution control table, and is therefore using the resources associated wi… |
1.3.6.1.4.1.2.6.45.2.1.1.5 | protocolDistControlStatus | 0 | 0 | The status of this protocol distribution control entry. |