Reference record for OID 1.3.6.1.4.1.2011.10.2.14.2.1.4
- parent
- 1.3.6.1.4.1.2011.10.2.14.2.1 (h3cMainPseEntry)
- node code
- 4
- node name
- h3cMainGuaranteedPowerRemaining
- dot oid
- 1.3.6.1.4.1.2011.10.2.14.2.1.4
- type
- OBJECT-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) huawei(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) iMAP(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- ...skipped...
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) huawei(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) iMAP(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) huawei(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) iMAP(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- ...skipped...
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) huawei(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) iMAP(2011) h3c(10) h3cCommon(2) h3cPowerEthernetExt(14) h3cMainPseTable(2) h3cMainPseEntry(1) h3cMainGuaranteedPowerRemaining(4)}
- iri oid
-
- /iso/identified-organization/dod/internet/private/enterprise/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- /iso/identified-organization/dod/internet/private/enterprise/iMAP/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- ...skipped...
- /iso/org/dod/internet/private/enterprise/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- /iso/org/dod/internet/private/enterprise/iMAP/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- /iso/org/dod/internet/private/enterprises/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- /iso/org/dod/internet/private/enterprises/iMAP/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- ...skipped...
- /iso/iso-identified-organization/dod/internet/private/enterprises/huawei/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- /iso/iso-identified-organization/dod/internet/private/enterprises/iMAP/h3c/h3cCommon/h3cPowerEthernetExt/h3cMainPseTable/h3cMainPseEntry/h3cMainGuaranteedPowerRemaining
- iri by oid_info
- /ISO/Identified-Organization/6/1/4/1/2011/10/2/14/2/1/4
Description by mibdepot
The object specifies the amount of power remaining in the
guaranteed power pool. Each time a port is placed into guaranteed mode it reserves a set amount of
power out of the total guaranteed power pool for the system. This intention of this object is to give the
client of this MIB (whether that be the CLI or the Web interface or the end user) an indication of how many
ports can still be placed into guaranteed mode. It is a read only integer value with units of Watts
(note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters,
such as the pethMainPsePower object, in units of Watts).
Parsed from file h3c-power-eth-ext.mib.txt
Company: huawei
Module: H3C-POWER-ETH-EXT-MIB
Information by oid_info
Vendor: Huawei
Module: H3C-POWER-ETH-EXT-MIB (h3c-power-eth-ext.mib)
Type: TABULAR
Access: read-only
Syntax: Integer32
Automatically extracted from www.mibdepot.com
Information by mibdepot
h3cMainGuaranteedPowerRemaining OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the amount of power remaining in the
guaranteed power pool. Each time a port is placed into guaranteed mode it reserves a set amount of
power out of the total guaranteed power pool for the system. This intention of this object is to give the
client of this MIB (whether that be the CLI or the Web interface or the end user) an indication of how many
ports can still be placed into guaranteed mode. It is a read only integer value with units of Watts
(note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters,
such as the pethMainPsePower object, in units of Watts)."
::= { h3cMainPseEntry 4 }
First Registration Authority (recovered by parent 1.3.6.1.4.1.2011)
Lwu Zhao
Brothers (5)
OID | Name | Sub children | Sub Nodes Total | Description |
1.3.6.1.4.1.2011.10.2.14.2.1.1 |
h3cMainPsePowerLimit |
0 |
0 |
The object specifies the power limit set for the unit as a whole. The PoE unit will already have a nominal power defined by the… |
1.3.6.1.4.1.2011.10.2.14.2.1.2 |
h3cMainPseAveragePower |
0 |
0 |
The object specifies the average power which has been consumed by the port. It is a read/write integer value with units of Watt… |
1.3.6.1.4.1.2011.10.2.14.2.1.3 |
h3cMainPsePeakPower |
0 |
0 |
The object specifies the peak power which has been consumed for PoE. It is defined as the highest measured value of power in mi… |
1.3.6.1.4.1.2011.10.2.14.2.1.5 |
h3cMainPsePriorityMode |
0 |
0 |
Describes or controls the priority mode on slot which must be enabled firstly. When a new board is inserted, and the power is ov… |
1.3.6.1.4.1.2011.10.2.14.2.1.6 |
h3cMainPseLegacy |
0 |
0 |
Describes or controls the legacy mode on slot which must be enabled firstly. Legacy mode: standard or nonstandard PD detection m… |