Vendor: HUAWEI Technology Co.,Ltd
Module: HW-IMAPV1NORTHBOUND-TRAP-MIB
[Automatically extracted from oidview.com]
hwNmNorthboundEventInfo OBJECT IDENTIFIER ::= { hwNmNorthboundEvent 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2011.2.15.1.7.1.1 | hwNmNorthboundEventNotify, hwNmNorthboundNEName | 0 | 0 | The name of network element,string (255) |
1.3.6.1.4.1.2011.2.15.1.7.1.2 | hwNmNorthboundNEType | 0 | 0 | Device type of element,string(64) |
1.3.6.1.4.1.2011.2.15.1.7.1.3 | hwNmNorthboundEventNotifyCritical, hwNmNorthboundObjectInstance | 0 | 0 | Instance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255) |
1.3.6.1.4.1.2011.2.15.1.7.1.4 | hwNmNorthboundEventNotifyMajor, hwNmNorthboundEventType | 0 | 0 | Event type of Network management,string(64) |
1.3.6.1.4.1.2011.2.15.1.7.1.5 | hwNmNorthboundEventNotifyMinor, hwNmNorthboundEventTime | 0 | 0 | Alarm generate time,string(64),format: 2003/03/14 00:00:00 |
1.3.6.1.4.1.2011.2.15.1.7.1.6 | hwNmNorthboundEventNotifyWarning, hwNmNorthboundProbableCause | 0 | 0 | Reason of Probable caused alarm, string(64) |
1.3.6.1.4.1.2011.2.15.1.7.1.7 | hwNmNorthboundEventNotifyIndefinitely, hwNmNorthboundSeverity | 0 | 0 | Level of Alarm, string(64) |
1.3.6.1.4.1.2011.2.15.1.7.1.8 | hwNmNorthboundEventDetail | 0 | 0 | Alarm ID and detail information, format: ID+detail infomation, string(255) |
1.3.6.1.4.1.2011.2.15.1.7.1.9 | hwNmNorthboundAdditionalInfo | 0 | 0 | Additional infomation of device, such as Country, City and so on, string(255) |
1.3.6.1.4.1.2011.2.15.1.7.1.10 | hwNmNorthboundFaultFlag | 0 | 0 | The flag of the fault.Show whether the alarm is an event ,a fault alarm or a recovery alarm. |
1.3.6.1.4.1.2011.2.15.1.7.1.11 | hwNmNorthboundFaultFunction | 0 | 0 | The function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run'… |
1.3.6.1.4.1.2011.2.15.1.7.1.12 | hwNmNorthboundDeviceIP | 0 | 0 | The IP address of the device |
1.3.6.1.4.1.2011.2.15.1.7.1.13 | hwNmNorthboundSerialNo | 0 | 0 | The serial number of alarm. |
1.3.6.1.4.1.2011.2.15.1.7.1.14 | hwNmNorthboundProbableRepair | 0 | 0 | The probable repair advice of the alarm. |
1.3.6.1.4.1.2011.2.15.1.7.1.15 | hwNmNorthboundResourceIDs | 0 | 0 | The ID of the resource. |
1.3.6.1.4.1.2011.2.15.1.7.1.16 | hwNmNorthboundsAdditionalVB1 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.17 | hwNmNorthboundsAdditionalVB2 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.18 | hwNmNorthboundsAdditionalVB3 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.19 | hwNmNorthboundsAdditionalVB4 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.20 | hwNmNorthboundsAdditionalVB5 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.21 | hwNmNorthboundsAdditionalVB6 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.22 | hwNmNorthboundsAdditionalVB7 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.23 | hwNmNorthboundsAdditionalVB8 | 0 | 0 | Addtional information of the alarm |
1.3.6.1.4.1.2011.2.15.1.7.1.24 | hwNmNorthboundEventName | 0 | 0 | The name of event,string (255) |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2011.2.15.1.7.2 | hwNmNorthboundEventKeepAliveInfo | 1 | 1 | None |
1.3.6.1.4.1.2011.2.15.1.7.7 | hwNmNorthboundEventSynchronization | 5 | 10 | None |