This object identifies the value that is used for the
RxBe parameter when a non-configured PVC is detected by
the hardware.
Parsed from file crcnp64.mib.txt
Company: paradyne
Module: CRC-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
crc110PCAutoRxBe OBJECT-TYPE SYNTAX INTEGER (0..1536) ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies the value that is used for the RxBe parameter when a non-configured PVC is detected by the hardware." ::= { crc110CGPvcPerformConfig 21 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2066.3.4.6.21.0 | crc110PCAutoRxBe | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2066.3.4.6.1 | crc110PCMonPktsRate | 1 | 1 | This object identifies the desired packet rate in seconds for latency test. |
1.3.6.1.4.1.2066.3.4.6.2 | crc110PCMinPktsForDelayAlarm | 1 | 1 | This object identifies the min packets for average delay alarm. |
1.3.6.1.4.1.2066.3.4.6.3 | crc110PCDrpdMonPktThres | 1 | 1 | This object identifies the latency test packet lost threshold. |
1.3.6.1.4.1.2066.3.4.6.4 | crc110PCDelayThreshold | 1 | 1 | This object identifies the average latency delay threshold. |
1.3.6.1.4.1.2066.3.4.6.5 | crc110PCStatsHistoryInterval | 1 | 1 | This object identifies the number of minutes per interval for PVC Statistics. |
1.3.6.1.4.1.2066.3.4.6.6 | crc110PCPvcPerfMonTable | 1 | 9 | None |
1.3.6.1.4.1.2066.3.4.6.7 | crc110PCFrameLostMonitorRate | 1 | 1 | This object identifies the rate at which frame loss packets are sent in seconds. |
1.3.6.1.4.1.2066.3.4.6.8 | crc110PCDlvdPktThres | 1 | 1 | This object identifies the minimum percentage of packets that must be delivered on any monitored PVC in an interval. |
1.3.6.1.4.1.2066.3.4.6.9 | crc110PCCirFromLmi | 1 | 1 | This object identifies from where the Cir values should be used. |
1.3.6.1.4.1.2066.3.4.6.10 | crc110PCCirBin1 | 1 | 1 | This object identifies the percentage of Cir used for the Tc Bin 1 counter. |
1.3.6.1.4.1.2066.3.4.6.11 | crc110PCCirBin2 | 1 | 1 | This object identifies the percentage of Cir used for the Tc Bin 2 counter. |
1.3.6.1.4.1.2066.3.4.6.12 | crc110PCCirBin3 | 1 | 1 | This object identifies the percentage of Cir used for the Tc Bin 3 counter. |
1.3.6.1.4.1.2066.3.4.6.13 | crc110PCCirBin4 | 1 | 1 | This object identifies the percentage of Cir used for the Tc Bin 4 counter. |
1.3.6.1.4.1.2066.3.4.6.14 | crc110PCCirBin5 | 1 | 1 | This object identifies the percentage of Cir used for the Tc Bin 5 counter. |
1.3.6.1.4.1.2066.3.4.6.15 | crc110PCCirBin6 | 1 | 1 | This object identifies the percentage of Cir used for the Tc Bin 6 counter. |
1.3.6.1.4.1.2066.3.4.6.16 | crc110PCAutoTxCir | 1 | 1 | This object identifies the value to be used for the TxCir parameter when a non-configured PVC is detected by the hardware. |
1.3.6.1.4.1.2066.3.4.6.17 | crc110PCAutoTxBc | 1 | 1 | This object identifies the value that is used for the TxBc parameter when a non-configured PVC is detected by the hardware. |
1.3.6.1.4.1.2066.3.4.6.18 | crc110PCAutoTxBe | 1 | 1 | This object identifies the value that is used for the TxBe parameter when a non-configured PVC is detected by the hardware. |
1.3.6.1.4.1.2066.3.4.6.19 | crc110PCAutoRxCir | 1 | 1 | This object identifies the value that is used for the RxCir parameter when a non-configured PVC is detected by the hardware. |
1.3.6.1.4.1.2066.3.4.6.20 | crc110PCAutoRxBc | 1 | 1 | This object identifies the value that is used for the RxBc parameter when a non-configured PVC is detected by the hardware. |
1.3.6.1.4.1.2066.3.4.6.22 | crc110PCAutoMonType | 1 | 1 | This object identifies the value that is used for the MonType parameter when a non-configured PVC is detected by the hardware. |