Reference record for OID 1.3.6.1.4.1.21239.2.31.1


parent
1.3.6.1.4.1.21239.2.31 (t3hdSensorTable)
node code
1
node name
t3hdSensorEntry
dot oid
1.3.6.1.4.1.21239.2.31.1
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 21239(21239) geistV3(2) t3hdSensorTable(31) t3hdSensorEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 21239(21239) geistV3(2) t3hdSensorTable(31) t3hdSensorEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) 21239(21239) geistV3(2) t3hdSensorTable(31) t3hdSensorEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 21239(21239) geistV3(2) t3hdSensorTable(31) t3hdSensorEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 21239(21239) geistV3(2) t3hdSensorTable(31) t3hdSensorEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 21239(21239) geistV3(2) t3hdSensorTable(31) t3hdSensorEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/21239/geistV3/t3hdSensorTable/t3hdSensorEntry
  • /iso/identified-organization/dod/internet/private/enterprises/21239/geistV3/t3hdSensorTable/t3hdSensorEntry
  • /iso/org/dod/internet/private/enterprise/21239/geistV3/t3hdSensorTable/t3hdSensorEntry
  • /iso/org/dod/internet/private/enterprises/21239/geistV3/t3hdSensorTable/t3hdSensorEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/21239/geistV3/t3hdSensorTable/t3hdSensorEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/21239/geistV3/t3hdSensorTable/t3hdSensorEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/21239/2/31/1

    Description by oid_info

    t3hdSensorEntry OBJECT-TYPE
    SYNTAX T3hdSensorEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "Entry in the T3HD sensor table: each entry contains
    an index (t3hdIndex) and other sensor details"
    INDEX { t3hdSensorIndex }

    View at oid-info.com

    First Registration Authority (recovered by parent 1.3.6.1.4.1.21239)

    Preuss Brad Wilson or Jesse

    Children (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.21239.2.31.1.1 t3hdSensorIndex 0 0 t3hdSensorIndex OBJECT-TYPE
    SYNTAX INTEGER(1..100)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION "Table entry index valu…
    1.3.6.1.4.1.21239.2.31.1.2 t3hdSensorSerial 0 0 t3hdSensorSerial OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Serial Number"
    1.3.6.1.4.1.21239.2.31.1.3 t3hdSensorName 0 0 t3hdSensorName OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Friendly Name"
    1.3.6.1.4.1.21239.2.31.1.4 t3hdSensorAvail 0 0 t3hdSensorAvail OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Is device currently plugged in?"
    1.3.6.1.4.1.21239.2.31.1.5 t3hdSensorIntName 0 0 t3hdSensorIntName OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Internal Friendly Name"
    1.3.6.1.4.1.21239.2.31.1.6 t3hdSensorIntTempC 0 0 t3hdSensorIntTempC OBJECT-TYPE
    SYNTAX INTEGER(-50..100)
    UNITS "Degrees Celsius"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION…
    1.3.6.1.4.1.21239.2.31.1.7 t3hdSensorIntTempF 0 0 t3hdSensorIntTempF OBJECT-TYPE
    SYNTAX INTEGER(-58..212)
    UNITS "Degrees Fahrenheit"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPT…
    1.3.6.1.4.1.21239.2.31.1.8 t3hdSensorIntHumidity 0 0 t3hdSensorIntHumidity OBJECT-TYPE
    SYNTAX INTEGER(0..100)
    UNITS "%"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "Internal Hu…
    1.3.6.1.4.1.21239.2.31.1.9 t3hdSensorIntDewPointC 0 0 t3hdSensorIntDewPointC OBJECT-TYPE
    SYNTAX INTEGER(-50..100)
    UNITS "Degrees Celsius"
    MAX-ACCESS read-only
    STATUS current
    DESCRIP…
    1.3.6.1.4.1.21239.2.31.1.10 t3hdSensorIntDewPointF 0 0 t3hdSensorIntDewPointF OBJECT-TYPE
    SYNTAX INTEGER(-58..212)
    UNITS "Degress Fahrenheit"
    MAX-ACCESS read-only
    STATUS current
    DESC…
    1.3.6.1.4.1.21239.2.31.1.11 t3hdSensorExt1Avail 0 0 t3hdSensorExt1Avail OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "External 1 status: 0 = unplugge…
    1.3.6.1.4.1.21239.2.31.1.12 t3hdSensorExt1Name 0 0 t3hdSensorExt1Name OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "External 1 Friendly Name"
    1.3.6.1.4.1.21239.2.31.1.13 t3hdSensorExt1TempC 0 0 t3hdSensorExt1TempC OBJECT-TYPE
    SYNTAX INTEGER(-50..100)
    UNITS "Degrees Celsius"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTIO…
    1.3.6.1.4.1.21239.2.31.1.14 t3hdSensorExt1TempF 0 0 t3hdSensorExt1TempF OBJECT-TYPE
    SYNTAX INTEGER(-58..212)
    UNITS "Degress Fahrenheit"
    MAX-ACCESS read-only
    STATUS current
    DESCRIP…
    1.3.6.1.4.1.21239.2.31.1.15 t3hdSensorExt2Avail 0 0 t3hdSensorExt2Avail OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "External 2 status: 0 = unplugge…
    1.3.6.1.4.1.21239.2.31.1.16 t3hdSensorExt2Name 0 0 t3hdSensorExt2Name OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "External 2 Friendly Name"
    1.3.6.1.4.1.21239.2.31.1.17 t3hdSensorExt2TempC 0 0 t3hdSensorExt2TempC OBJECT-TYPE
    SYNTAX INTEGER(-50..100)
    UNITS "Degrees Celsius"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTIO…
    1.3.6.1.4.1.21239.2.31.1.18 t3hdSensorExt2TempF 0 0 t3hdSensorExt2TempF OBJECT-TYPE
    SYNTAX INTEGER(-58..212)
    UNITS "Degress Fahrenheit"
    MAX-ACCESS read-only
    STATUS current
    DESCRIP…