Vendor: SALIX Technologies, Inc.
Module: SALIX-SYSTEM-MIB
[Automatically extracted from oidview.com]
salixSystemSync OBJECT IDENTIFIER ::= { salixSystemMIBObjects 5 }
salixSystemSync OBJECT IDENTIFIER ::= { salixSystemMIBObjects 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.2.3.1.5.1 | salixSysSyncTimingMode | 1 | 1 | An identification of the source from which timing is derived by the working sync module. Possible values are: internal(1) - the … |
1.3.6.1.4.1.2158.2.3.1.5.2 | salixSysSyncPrimaryRef | 1 | 1 | The interface index of the primary reference line from which the sync module can derive timing. If the 'salixSysSyncTimingMode' … |
1.3.6.1.4.1.2158.2.3.1.5.3 | salixSysSyncSecondaryRef | 1 | 1 | The interface index of the secondary reference line from which the sync module can derive timing. If the 'salixSysSyncTimingMode… |
1.3.6.1.4.1.2158.2.3.1.5.4 | salixSysSyncRevertiveSwitch | 1 | 1 | Indication of whether or not the active interface for deriving timing should revert to the interface defined by the primary refer… |
1.3.6.1.4.1.2158.2.3.1.5.5 | salixSysSyncClockMode | 1 | 1 | Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's … |
1.3.6.1.4.1.2158.2.3.1.5.6 | salixSysSyncConfiguredActiveRef | 1 | 1 | The configured active reference line from which the sync module should deriving its timing. This object is relevant if the 'sali… |
1.3.6.1.4.1.2158.2.3.1.5.7 | salixSysSyncAutoRefSwitch | 1 | 1 | Indication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - A… |
1.3.6.1.4.1.2158.2.3.1.5.8 | salixSysSyncFreeRunAlarm | 1 | 1 | Indication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disab… |
1.3.6.1.4.1.2158.2.3.1.5.9 | salixSysSyncWorking | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to … |
1.3.6.1.4.1.2158.2.3.1.5.10 | salixSysSyncProtect | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 in… |
1.3.6.1.4.1.2158.2.3.1.5.11 | salixSysSyncPrimaryRefState | 1 | 1 | This variable indicates the state of the primary reference line termination point to be used as a timing source by the sync modul… |
1.3.6.1.4.1.2158.2.3.1.5.12 | salixSysSyncSecondaryRefState | 1 | 1 | This variable indicates the state of the secondary reference line termination point to be used as a timing source by the sync mod… |
1.3.6.1.4.1.2158.2.3.1.5.13 | salixSysSyncCurrentActiveRef | 1 | 1 | Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the salixS… |
1.3.6.1.4.1.2158.2.3.1.5.14 | salixSysSyncForcedState | 1 | 1 | This variable indicates the state of the sync module with regard to switching between the configured active reference, the value … |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.2.3.1.1 | salixSysLastLogErrorNumber | 1 | 1 | The error number that is associate with the last set request. |
1.3.6.1.4.1.2158.2.3.1.2 | salixSysLastLogErrorMessage | 1 | 1 | The error message that describes the error associated with the last set request. |
1.3.6.1.4.1.2158.2.3.1.3 | salixSysLastLogErrorOid | 1 | 1 | The last set request OID that produced an error. |
1.3.6.1.4.1.2158.2.3.1.4 | salixSysTemperature | 1 | 1 | The temperature in degrees Celsius inside the chassis. |
1.3.6.1.4.1.2158.2.3.1.6 | salixSystemHsf | 2 | 4 | None |
1.3.6.1.4.1.2158.2.3.1.7 | salixSystemRsc | 2 | 4 | None |
1.3.6.1.4.1.2158.2.3.1.8 | salixSysLoginMessage | 1 | 1 | The message is displayed every time a user logs into the CLI. It may be used to display legal warnings. |