Original text from OID Repository
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A bit array specifying which traps the station
wishes to receive with confirmed delivery. Any
bits set must also be set in
adminNotificationTrapMask. If a trap sent with
confirmed delivery is not acknowledged within
adminNotificationTimeout seconds it is sent again.
After adminNotificationRetries attempts to deliver
the trap, the LANtern network monitor gives up, and
tries to deliver it to the station specified by
adminNotificationBackup."
DEFVAL { 0 } -- No confirmed traps