Vendor: Computer Associates
Module: SNI-SERVER-CONTROL-MIB (SC.mib)
Type: ENTRY
Access: not-accessible
Syntax: CabinetInfos
Automatically extracted from www.mibdepot.com
cabinetInfos OBJECT-TYPE SYNTAX CabinetInfos ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { cabinetId } ::= { cabinetInfosTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.1 | cabinetId | 0 | 0 | Cabinet ID number, index into the cabinet table (0..99) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.2 | cabinetLocation | 0 | 0 | The place where the cabinet is located (user can store any string here to identify the cabinet location) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.3 | cabinetIdentNumber | 0 | 0 | System ident number (serial number) - will be a number like 'XYZZ 12345678'. XYZZ is the cabinet identifier and is mandatory… |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.4 | cabinetSystemName | 0 | 0 | System name string (i.e. PCD-5S, Primergy 150...) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.5 | cabinetNumberFans | 0 | 0 | The number of configured cooling devices (fans) in this cabinet (-1 = unknown) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.6 | cabinetNumberTempSensors | 0 | 0 | The number of configured temperature sensors in this cabinet (-1 = unknown) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.7 | cabinetNumberPowerSupplies | 0 | 0 | The number of available power supplies in this cabinet (-1 = unknown) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.8 | cabinetPowerSupplySlots | 0 | 0 | The number of power supply slots in this cabinet (is the maximum number of installable power supplies; 0 if no hot-plug slots ava… |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.9 | cabinetUpsUsed | 0 | 0 | Uninterruptable power supply for this cabinet available: 0: No UPS 1..n: Index in UPS table -1: unknown |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.10 | cabinetBoardSerialNumber | 0 | 0 | Serial number of the cabinet's system board |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.11 | cabinetBoardRevision | 0 | 0 | Revision (GS) of the cabinet's system board (-1 = unknown) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.12 | cabinetBoardId | 0 | 0 | Identifier string of the cabinet's system board |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.13 | cabinetManagementControllerType | 0 | 0 | Type of the cabinet's system management controller (i.e. SNI System Control Board) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.14 | cabinetControllerFirmwareMajor | 0 | 0 | Firmware version (major number) of the cabinet's system management controller (-1 = unknown) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.15 | cabinetControllerFirmwareMinor | 0 | 0 | Firmware version (minor number) of the cabinet's system management controller (-1 = unknown) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.16 | cabinetAttribute | 0 | 0 | Attribute of a cabinet (Primary/secondary server, storage extension...) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.17 | cabinetPowerOnStatus | 0 | 0 | Power-on state of the cabinet |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.18 | cabinetStatusSummary | 0 | 0 | Describes the status of a cabinet (OK, degraded, error...) |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.19 | cabinetLastPoweroffSource | 0 | 0 | The source from which the cabinet was powered off last time |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.20 | cabinetActionAfterAcFail | 0 | 0 | Action on AC power resume after AC has failed. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.21 | cabinetBbuUsed | 0 | 0 | Battery buffering unit for this cabinet available. The value unknown(1) cannot be set, a SET will deliver 'badValue'. |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.22 | cabinetSystemType | 0 | 0 | Type of the cabinet (values for PCE-5S, Primergy xxx, PCD-SE...). The value unknown(1) cannot be set, a SET will deliver 'badVal… |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23 | cabinetStatusDetail | 0 | 0 | More detailed status information from this cabinet. The StatusDetail object is set to reflect the new status. ok: … |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.24 | cabinetHousingType | 0 | 0 | Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cab… |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.25 | cabinetFrontDoorStatus | 0 | 0 | Status of the cabinet's front door |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.26 | cabinetHousingOpenStatus | 0 | 0 | Status describing whether the housing is open or closed |
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.27 | sniScCabinetNumberVoltages | 1 | 1 | Number of entries in power supply voltage table |